Journal & Issues

Volume 29 (2023): Issue 2 (June 2023)

Volume 29 (2023): Issue 1 (March 2023)

Volume 28 (2022): Issue 4 (December 2022)

Volume 28 (2022): Issue 3 (September 2022)

Volume 28 (2022): Issue 2 (June 2022)

Volume 28 (2022): Issue 1 (March 2022)

Volume 27 (2021): Issue 4 (December 2021)

Volume 27 (2021): Issue 3 (September 2021)

Volume 27 (2021): Issue 2 (June 2021)

Volume 27 (2021): Issue 1 (March 2021)

Volume 26 (2020): Issue 4 (December 2020)

Volume 26 (2020): Issue 3 (September 2020)

Volume 26 (2020): Issue 2 (June 2020)

Volume 26 (2020): Issue 1 (March 2020)

Volume 25 (2019): Issue 4 (December 2019)

Volume 25 (2019): Issue 3 (September 2019)

Volume 25 (2019): Issue 2 (June 2019)

Volume 25 (2019): Issue 1 (March 2019)

Volume 24 (2018): Issue 4 (December 2018)

Volume 24 (2018): Issue 3 (September 2018)

Volume 24 (2018): Issue 2 (June 2018)

Volume 24 (2018): Issue 1 (March 2018)

Volume 23 (2017): Issue 4 (December 2017)

Volume 23 (2017): Issue 3 (September 2017)

Volume 23 (2017): Issue 2 (June 2017)

Volume 23 (2017): Issue 1 (March 2017)

Volume 22 (2016): Issue 4 (December 2016)

Volume 22 (2016): Issue 3 (September 2016)

Volume 22 (2016): Issue 2 (June 2016)

Volume 22 (2016): Issue 1 (March 2016)

Volume 21 (2015): Issue 1 (December 2015)

Volume 20 (2014): Issue 1 (March 2014)

Volume 19 (2013): Issue 2 (December 2013)

Volume 19 (2013): Issue 1 (March 2013)

Volume 18 (2012): Issue 2 (June 2012)

Volume 18 (2012): Issue 1 (March 2012)

Volume 17 (2011): Issue 4 (December 2011)

Volume 17 (2011): Issue 3 (September 2011)

Volume 17 (2011): Issue 2 (June 2011)

Volume 17 (2011): Issue 1 (March 2011)

Volume 16 (2010): Issue 2 (June 2010)

Volume 16 (2010): Issue 1 (March 2010)

Volume 15 (2009): Issue 4 (December 2009)

Volume 15 (2009): Issue 3 (September 2009)

Volume 15 (2009): Issue 2 (June 2009)

Volume 15 (2009): Issue 1 (March 2009)

Volume 14 (2008): Issue 4 (December 2008)

Volume 14 (2008): Issue 3 (September 2008)

Volume 14 (2008): Issue 2 (June 2008)

Volume 14 (2008): Issue 1 (March 2008)

Volume 13 (2007): Issue 4 (December 2007)

Volume 13 (2007): Issue 3 (September 2007)

Volume 13 (2007): Issue 2 (June 2007)

Volume 13 (2007): Issue 1 (March 2007)

Journal Details
Format
Journal
eISSN
1898-0309
First Published
30 Dec 2008
Publication timeframe
4 times per year
Languages
English

Search

Volume 26 (2020): Issue 3 (September 2020)

Journal Details
Format
Journal
eISSN
1898-0309
First Published
30 Dec 2008
Publication timeframe
4 times per year
Languages
English

Search

6 Articles
Open Access

The dependence of inhomogeneity correction factors on photon beam quality index performed with the Anisotropic Analytical Algorithm

Published Online: 29 Sep 2020
Page range: 127 - 134

Abstract

Abstract

Purpose: The purpose of the study was to investigate the dependence of tissue inhomogeneity correction factors (ICFs) on the photon beam quality index (QI).

Materials and Methods: Heterogeneous phantoms, comprising semi-infinite slabs of the lung (0.10, 0.20, 0.26 and 0.30 g/cm3), adipose tissue (0.92 g/cm3) and bone (1.85 g/cm3) in water, were constructed in the Eclipse treatment planning system. Several calculation models of 6 MV and 15 MV photon beams for quality index (TPR20,10) = 0.670±k*0.01 and TPR20,10 = 0.760±k*0.01, k = -3, -2, -1, 0, 1, 2, 3 respectively were built in the Eclipse. The ICFs were calculated with the anisotropic analytical algorithm (AAA) for several beam sizes and points lying at several depths inside of and below inhomogeneities of different thicknesses.

Results: The ICFs increased for lung and adipose tissues with increasing beam quality (TPR20,10), while decreased for bone. Calculations with AAA predict that the maximum difference in ICFs of 1.0% and 2.5% for adipose and bone tissues, respectively. For lung tissue, changes of ICFs of a maximum of 9.2% (6 MV) and 13.8% (15 MV). For points where charged particle equilibrium exists, a linear dependence of ICFs on TPR20,10 was observed. If CPE doesn’t exist, the dependence became more complex. For points inside of the low-density inhomogeneity, the dependence of the ICFs on energy was not linear but the changes of ICFs were smaller than 3.0%. Measurements results carried out with the CIRS phantom were consistent with the calculation results.

Conclusions: A negligible dependence of the ICFs on energy was found for adipose and bone tissue. For lung tissue, in the CPE region, the dependence of ICFs on different beam quality indexes with the same nominal energy may not be neglected, however, this dependence was linear. Where there is no CPE, the dependence of the ICFs on energy was more complicated.

Keywords

  • photon beam
  • quality index
  • dose calculation
  • AAA
  • inhomogeneity correction factors
Open Access

Point dose verification of Cranial Stereotactic Radiosurgery using micro Ionization Chamber and EBT3 film for 6MV FF and FFF beams in Varian TrueBeam® LINAC

Published Online: 29 Sep 2020
Page range: 135 - 142

Abstract

Abstract

Introduction: Achieving high positional and dosimetric accuracy in small fields is very challenging due to the imbalance of charged particle equilibrium (CPE), occlusion of the primary radiation source, and overlapping penumbra regions. These factors make the choice of the detector for Stereotactic Radiosurgery (SRS) patient-specific quality assurance (PSQA) difficult. The aim of the study is to compare the suitability of EBT3 Gafchromic film against CC01 pinpoint chamber for the purpose of SRS and stereotactic Radiotherapy (SRT) dose verification.

Material and Method: EBT3 Gafchromic film was calibrated against Treatment Planning System (TPS) doses (1 Gy – 35 Gy). CC01 pinpoint chamber and EBT3 film was used to verify Patient-Specific point doses of 21 intracranial lesions each planned with Static, Dynamic Conformal Arc (DCA), and Volumetric Arc Therapy (VMAT) using Varian TrueBeam Accelerator 6MV Flattening Filter (FF) and 6MV Flattening Filter Free (FFF) beams. The lesion sizes varied from 0.4 cc to 2.9 cc. The lesions were categorized into <1cc, 1cc-2cc and 2cc-3cc.

Results: High variations in measured doses from TPS calculated dose were observed with small lesion volumes irrespective of the dosimeter. As the sizes decreased high uncertainty was observed in ion chamber results. CC01 was observed under-responding to film in small lesion sizes (<1cc), where nearly 50% of results under-responded in comparison with Film results. Film results were more or less consistent for static and DCA plans. Static and DCA plans were consistent passing more than 73% of the plans of the smallest lesion size category. VMAT showed very poor PSQA agreement for all three volumes (32.1% for <1cc, 14.3% for 2cc-3cc and 39.3% for 2cc-3cc). No significant difference was observed between 6MVFF and 6MVFFF beams from the chi-squared test.

Conclusion: EBT3 Film was observed to be a more suitable detector for small lesion sizes less than 1cc, compared to CC01. As the volume increases, the response of CC01 and EBT3 film have no significant difference in performing PSQA for intracranial SRS/SRT. VMAT techniques for intra cranial SRS shows deviation from TPS planned dose for both EBT3 film and CC01 and should not be preferred choice of verification tools.

Keywords

  • patient specific quality assurance
  • stereotactic radiosurgery
  • EBT3 Gafchromic film
  • CC01 pinpoint chamber
  • flattening filter free photon beams
Open Access

Effect of gender and occupations on uranium concentration in human blood and soil samples collected from Babylon, Iraq

Published Online: 29 Sep 2020
Page range: 143 - 148

Abstract

Abstract

Uranium concentrations of human blood and soil samples have been studied at different ages and occupations in Babylon, Iraq. The technique of nuclear track detectors CR 39 with nuclear fission track analysis has been used to determine the uranium concentrations in this study. Results have shown that the concentrations of uranium ranged from 0.56 ± 0.06 to 1.24 ± 0.29 ppb with an average of 0.83 ± 0.18 ppb in blood samples. On the other hand, the concentrations of uranium in soil samples ranged from 0.93 ± 0.20 to 2.59 ± 0.15 ppm with an average of 1.72 ± 0.19 ppm. Moreover, the highest averages of concentration have been found in the city center of Babylon, reaching 1.09 ± 0.22 ppb and 2.10 ± 0.23 ppm in blood and soil samples, respectively. The results have further proved that gender and occupations have an effect in increasing the concentrations of uranium. In addition, the concentrations in blood samples are generally lower than the concentration in soil samples.

Keywords

  • uranium
  • occupations
  • gender
  • human blood
  • soil
  • CR 39
Open Access

Application of the continuous wavelet transform for the analysis of pathological severity degree of electromyograms (EMGs) signals

Published Online: 29 Sep 2020
Page range: 149 - 154

Abstract

Abstract

The aim of this work was twofold: first, to propose signal processing methods for assessing the temporal and spectral changes of parameters (mean absolute value, the energy and standard deviation as temporal parameters, total and mean power as frequency parameters) of the surface myoelectric signal of the various patient groups like normal, myopathic and neuropathic during muscles contraction of biceps. Secondly, to analyze this electrical manifestation of neuromuscular disorders by the implementation of time-frequency analysis using continuous wavelet that allows us to qualify this method to evaluate, appreciate the pathology and determine its degree of severity which was unable by extracting mentioned parameters. Our results showed that this approach presents satisfactory performances especially to follow patients with the least severe pathology.

Keywords

  • EMG
  • parameters
  • time-frequency
  • continuous wavelet
  • severity
Open Access

Diagnosis of amyotrophic lateral sclerosis (ALS) disorders based on electromyogram (EMG) signal analysis and feature selection

Published Online: 29 Sep 2020
Page range: 155 - 160

Abstract

Abstract

Electromyogram signal (EMG) provides an important source of information for the diagnosis of neuromuscular disorders. In this study, we proposed two methods of analysis which concern the bispectrum and continuous wavelet transform (CWT) of the EMG signal then a comparison is made to select which one is the most suitable to identify an abnormality in biceps brachii muscle in the main purpose is to assess the pathological severity in bifrequency and time-frequency analysis applying respectively bispectrum and CWT. Then four time and frequency features are extracted and three popular machine learning algorithms are implemented to differentiate neuropathy and healthy conditions of the selected muscle. The performance of these time and frequency features are compared using support vector machine (SVM), linear discriminate analysis (LDA) and K-Nearest Neighbor (KNN) classifier performance. The results obtained showed that the SVM classifier yielded the best performance with an accuracy of 95.8%, precision of 92.59% and specificity of 92%. followed by respectively KNN and LDA classifier that achieved respectively an accuracy of 92% and 91.5%, precision of 92% and 85.4%, and specificity of 92% and 83%.

Keywords

  • bispectrum
  • continuous wavelet transforms (CWT)
  • support vector machine (SVM)
  • linear discriminate analysis (LDA)
  • K-Nearest Neighbor (KNN)
Open Access

Alcohol addiction diagnosis on the basis of the polysomnographic parameters

Published Online: 29 Sep 2020
Page range: 161 - 167

Abstract

Abstract

Alcoholism is one of the most widely occurring addiction in the world. In this paper, we proposed the method of addiction detection based on polysomnography. We have got the sleep records which were described by numerical parameters calculated from standard processed records of polysomnography signals. The database used in the experiments consisted of 172 examinations: 50% of healthy and alcohol-addicted patients, and 50% males and females, with normal-like age distribution. For the diagnosis, we have used the decision system built on an artificial neural network.

In our investigations, we have optimised the input set of parameters and the network structure. To verify the correctness of the diagnosis we have used the “leave one out” validation method.

Finally, we have obtained over 97% correctness of alcohol addiction diagnoses for different, optimised sets of data for men and women. we got the 8 parameters described men and 11 for women where only 5 has been common. What must be underlined such a positive result was obtained by dividing the data base. For the whole base, we have got only about 89% correct diagnoses.

Keywords

  • alcohol addiction
  • sleep disturbance
  • polysomnogram
  • diagnosis
  • artificial neural networks
6 Articles
Open Access

The dependence of inhomogeneity correction factors on photon beam quality index performed with the Anisotropic Analytical Algorithm

Published Online: 29 Sep 2020
Page range: 127 - 134

Abstract

Abstract

Purpose: The purpose of the study was to investigate the dependence of tissue inhomogeneity correction factors (ICFs) on the photon beam quality index (QI).

Materials and Methods: Heterogeneous phantoms, comprising semi-infinite slabs of the lung (0.10, 0.20, 0.26 and 0.30 g/cm3), adipose tissue (0.92 g/cm3) and bone (1.85 g/cm3) in water, were constructed in the Eclipse treatment planning system. Several calculation models of 6 MV and 15 MV photon beams for quality index (TPR20,10) = 0.670±k*0.01 and TPR20,10 = 0.760±k*0.01, k = -3, -2, -1, 0, 1, 2, 3 respectively were built in the Eclipse. The ICFs were calculated with the anisotropic analytical algorithm (AAA) for several beam sizes and points lying at several depths inside of and below inhomogeneities of different thicknesses.

Results: The ICFs increased for lung and adipose tissues with increasing beam quality (TPR20,10), while decreased for bone. Calculations with AAA predict that the maximum difference in ICFs of 1.0% and 2.5% for adipose and bone tissues, respectively. For lung tissue, changes of ICFs of a maximum of 9.2% (6 MV) and 13.8% (15 MV). For points where charged particle equilibrium exists, a linear dependence of ICFs on TPR20,10 was observed. If CPE doesn’t exist, the dependence became more complex. For points inside of the low-density inhomogeneity, the dependence of the ICFs on energy was not linear but the changes of ICFs were smaller than 3.0%. Measurements results carried out with the CIRS phantom were consistent with the calculation results.

Conclusions: A negligible dependence of the ICFs on energy was found for adipose and bone tissue. For lung tissue, in the CPE region, the dependence of ICFs on different beam quality indexes with the same nominal energy may not be neglected, however, this dependence was linear. Where there is no CPE, the dependence of the ICFs on energy was more complicated.

Keywords

  • photon beam
  • quality index
  • dose calculation
  • AAA
  • inhomogeneity correction factors
Open Access

Point dose verification of Cranial Stereotactic Radiosurgery using micro Ionization Chamber and EBT3 film for 6MV FF and FFF beams in Varian TrueBeam® LINAC

Published Online: 29 Sep 2020
Page range: 135 - 142

Abstract

Abstract

Introduction: Achieving high positional and dosimetric accuracy in small fields is very challenging due to the imbalance of charged particle equilibrium (CPE), occlusion of the primary radiation source, and overlapping penumbra regions. These factors make the choice of the detector for Stereotactic Radiosurgery (SRS) patient-specific quality assurance (PSQA) difficult. The aim of the study is to compare the suitability of EBT3 Gafchromic film against CC01 pinpoint chamber for the purpose of SRS and stereotactic Radiotherapy (SRT) dose verification.

Material and Method: EBT3 Gafchromic film was calibrated against Treatment Planning System (TPS) doses (1 Gy – 35 Gy). CC01 pinpoint chamber and EBT3 film was used to verify Patient-Specific point doses of 21 intracranial lesions each planned with Static, Dynamic Conformal Arc (DCA), and Volumetric Arc Therapy (VMAT) using Varian TrueBeam Accelerator 6MV Flattening Filter (FF) and 6MV Flattening Filter Free (FFF) beams. The lesion sizes varied from 0.4 cc to 2.9 cc. The lesions were categorized into <1cc, 1cc-2cc and 2cc-3cc.

Results: High variations in measured doses from TPS calculated dose were observed with small lesion volumes irrespective of the dosimeter. As the sizes decreased high uncertainty was observed in ion chamber results. CC01 was observed under-responding to film in small lesion sizes (<1cc), where nearly 50% of results under-responded in comparison with Film results. Film results were more or less consistent for static and DCA plans. Static and DCA plans were consistent passing more than 73% of the plans of the smallest lesion size category. VMAT showed very poor PSQA agreement for all three volumes (32.1% for <1cc, 14.3% for 2cc-3cc and 39.3% for 2cc-3cc). No significant difference was observed between 6MVFF and 6MVFFF beams from the chi-squared test.

Conclusion: EBT3 Film was observed to be a more suitable detector for small lesion sizes less than 1cc, compared to CC01. As the volume increases, the response of CC01 and EBT3 film have no significant difference in performing PSQA for intracranial SRS/SRT. VMAT techniques for intra cranial SRS shows deviation from TPS planned dose for both EBT3 film and CC01 and should not be preferred choice of verification tools.

Keywords

  • patient specific quality assurance
  • stereotactic radiosurgery
  • EBT3 Gafchromic film
  • CC01 pinpoint chamber
  • flattening filter free photon beams
Open Access

Effect of gender and occupations on uranium concentration in human blood and soil samples collected from Babylon, Iraq

Published Online: 29 Sep 2020
Page range: 143 - 148

Abstract

Abstract

Uranium concentrations of human blood and soil samples have been studied at different ages and occupations in Babylon, Iraq. The technique of nuclear track detectors CR 39 with nuclear fission track analysis has been used to determine the uranium concentrations in this study. Results have shown that the concentrations of uranium ranged from 0.56 ± 0.06 to 1.24 ± 0.29 ppb with an average of 0.83 ± 0.18 ppb in blood samples. On the other hand, the concentrations of uranium in soil samples ranged from 0.93 ± 0.20 to 2.59 ± 0.15 ppm with an average of 1.72 ± 0.19 ppm. Moreover, the highest averages of concentration have been found in the city center of Babylon, reaching 1.09 ± 0.22 ppb and 2.10 ± 0.23 ppm in blood and soil samples, respectively. The results have further proved that gender and occupations have an effect in increasing the concentrations of uranium. In addition, the concentrations in blood samples are generally lower than the concentration in soil samples.

Keywords

  • uranium
  • occupations
  • gender
  • human blood
  • soil
  • CR 39
Open Access

Application of the continuous wavelet transform for the analysis of pathological severity degree of electromyograms (EMGs) signals

Published Online: 29 Sep 2020
Page range: 149 - 154

Abstract

Abstract

The aim of this work was twofold: first, to propose signal processing methods for assessing the temporal and spectral changes of parameters (mean absolute value, the energy and standard deviation as temporal parameters, total and mean power as frequency parameters) of the surface myoelectric signal of the various patient groups like normal, myopathic and neuropathic during muscles contraction of biceps. Secondly, to analyze this electrical manifestation of neuromuscular disorders by the implementation of time-frequency analysis using continuous wavelet that allows us to qualify this method to evaluate, appreciate the pathology and determine its degree of severity which was unable by extracting mentioned parameters. Our results showed that this approach presents satisfactory performances especially to follow patients with the least severe pathology.

Keywords

  • EMG
  • parameters
  • time-frequency
  • continuous wavelet
  • severity
Open Access

Diagnosis of amyotrophic lateral sclerosis (ALS) disorders based on electromyogram (EMG) signal analysis and feature selection

Published Online: 29 Sep 2020
Page range: 155 - 160

Abstract

Abstract

Electromyogram signal (EMG) provides an important source of information for the diagnosis of neuromuscular disorders. In this study, we proposed two methods of analysis which concern the bispectrum and continuous wavelet transform (CWT) of the EMG signal then a comparison is made to select which one is the most suitable to identify an abnormality in biceps brachii muscle in the main purpose is to assess the pathological severity in bifrequency and time-frequency analysis applying respectively bispectrum and CWT. Then four time and frequency features are extracted and three popular machine learning algorithms are implemented to differentiate neuropathy and healthy conditions of the selected muscle. The performance of these time and frequency features are compared using support vector machine (SVM), linear discriminate analysis (LDA) and K-Nearest Neighbor (KNN) classifier performance. The results obtained showed that the SVM classifier yielded the best performance with an accuracy of 95.8%, precision of 92.59% and specificity of 92%. followed by respectively KNN and LDA classifier that achieved respectively an accuracy of 92% and 91.5%, precision of 92% and 85.4%, and specificity of 92% and 83%.

Keywords

  • bispectrum
  • continuous wavelet transforms (CWT)
  • support vector machine (SVM)
  • linear discriminate analysis (LDA)
  • K-Nearest Neighbor (KNN)
Open Access

Alcohol addiction diagnosis on the basis of the polysomnographic parameters

Published Online: 29 Sep 2020
Page range: 161 - 167

Abstract

Abstract

Alcoholism is one of the most widely occurring addiction in the world. In this paper, we proposed the method of addiction detection based on polysomnography. We have got the sleep records which were described by numerical parameters calculated from standard processed records of polysomnography signals. The database used in the experiments consisted of 172 examinations: 50% of healthy and alcohol-addicted patients, and 50% males and females, with normal-like age distribution. For the diagnosis, we have used the decision system built on an artificial neural network.

In our investigations, we have optimised the input set of parameters and the network structure. To verify the correctness of the diagnosis we have used the “leave one out” validation method.

Finally, we have obtained over 97% correctness of alcohol addiction diagnoses for different, optimised sets of data for men and women. we got the 8 parameters described men and 11 for women where only 5 has been common. What must be underlined such a positive result was obtained by dividing the data base. For the whole base, we have got only about 89% correct diagnoses.

Keywords

  • alcohol addiction
  • sleep disturbance
  • polysomnogram
  • diagnosis
  • artificial neural networks