Journal & Issues

Volume 29 (2023): Issue 4 (December 2023)

Volume 29 (2023): Issue 3 (September 2023)

Volume 29 (2023): Issue 2 (June 2023)

Volume 29 (2023): Issue 1 (March 2023)

Volume 28 (2022): Issue 4 (December 2022)

Volume 28 (2022): Issue 3 (September 2022)

Volume 28 (2022): Issue 2 (June 2022)

Volume 28 (2022): Issue 1 (March 2022)

Volume 27 (2021): Issue 4 (December 2021)

Volume 27 (2021): Issue 3 (September 2021)

Volume 27 (2021): Issue 2 (June 2021)

Volume 27 (2021): Issue 1 (March 2021)

Volume 26 (2020): Issue 4 (December 2020)

Volume 26 (2020): Issue 3 (September 2020)

Volume 26 (2020): Issue 2 (June 2020)

Volume 26 (2020): Issue 1 (March 2020)

Volume 25 (2019): Issue 4 (December 2019)

Volume 25 (2019): Issue 3 (September 2019)

Volume 25 (2019): Issue 2 (June 2019)

Volume 25 (2019): Issue 1 (March 2019)

Volume 24 (2018): Issue 4 (December 2018)

Volume 24 (2018): Issue 3 (September 2018)

Volume 24 (2018): Issue 2 (June 2018)

Volume 24 (2018): Issue 1 (March 2018)

Volume 23 (2017): Issue 4 (December 2017)

Volume 23 (2017): Issue 3 (September 2017)

Volume 23 (2017): Issue 2 (June 2017)

Volume 23 (2017): Issue 1 (March 2017)

Volume 22 (2016): Issue 4 (December 2016)

Volume 22 (2016): Issue 3 (September 2016)

Volume 22 (2016): Issue 2 (June 2016)

Volume 22 (2016): Issue 1 (March 2016)

Volume 21 (2015): Issue 1 (December 2015)

Volume 20 (2014): Issue 1 (March 2014)

Volume 19 (2014): Issue 2 (March 2014)

Volume 19 (2013): Issue 1 (March 2013)

Volume 18 (2012): Issue 2 (June 2012)

Volume 18 (2012): Issue 1 (March 2012)

Volume 17 (2011): Issue 4 (January 2011)

Volume 17 (2011): Issue 3 (January 2011)

Volume 17 (2011): Issue 2 (January 2011)

Volume 17 (2011): Issue 1 (January 2011)

Volume 16 (2010): Issue 2 (January 2010)

Volume 16 (2010): Issue 1 (January 2010)

Volume 15 (2009): Issue 4 (January 2009)

Volume 15 (2009): Issue 3 (January 2009)

Volume 15 (2009): Issue 2 (January 2009)

Volume 15 (2009): Issue 1 (January 2009)

Volume 14 (2008): Issue 4 (January 2008)

Volume 14 (2008): Issue 3 (January 2008)

Volume 14 (2008): Issue 2 (January 2008)

Volume 14 (2008): Issue 1 (January 2008)

Volume 13 (2007): Issue 4 (January 2007)

Volume 13 (2007): Issue 3 (January 2007)

Volume 13 (2007): Issue 2 (January 2007)

Volume 13 (2007): Issue 1 (January 2007)

Journal Details
Format
Journal
eISSN
1898-0309
First Published
30 Dec 2008
Publication timeframe
4 times per year
Languages
English

Search

Volume 16 (2010): Issue 2 (January 2010)

Journal Details
Format
Journal
eISSN
1898-0309
First Published
30 Dec 2008
Publication timeframe
4 times per year
Languages
English

Search

0 Articles
Open Access

A novel technique to evaluate the geometrical accuracy of CT-MR image fusion in Gamma Knife radiosurgery procedures

Published Online: 05 May 2011
Page range: 55 - 66

Abstract

A novel technique to evaluate the geometrical accuracy of CT-MR image fusion in Gamma Knife radiosurgery procedures

In order to optimize the accuracy of imaging in Gamma Knife radiosurgery using the image fusion options available in the Leksell gamma plan. Phantom images from 1.5 Tesla MRI Scan (Magnetom vision - Siemens) and Computed Tomography images from Philips Brilliance 16 CT scanner were used for image fusion in Gammaplan treatment planning system. The images were fused using co-registration technique using multiview and imagemerge modules. Stereotactic coordinates were then calculated for known targets. Vector distances from the centre of the Leksell coordinate system to five known targets were measured in CT, MR and CT-MR fused images and compared with geometrical measurements. The mean values of maximum absolute errors were 0.34 mm, 0.41 mm.0.38 mm (along x-axis), 0.43 mm, 1.53 mm, 0.62 mm (along y-axis) and 0.75 mm 2.02 mm, 0.93 mm (along z-axis) for CT, MR and CT-MR fused image data respectively. The mean error in calculating the vector distances from the center of the Leksell coordinate system (100, 100, 100) to the known target volumes are 0.22 mm, 0.8 mm and 0.43 mm for CT, MR and CT-MR fused images, respectively. Image fusion functions available in gamma plan are useful for combining the features of CT and MR imaging modalities. These methods are highly useful in clinical situations where the error associated with Magnetic Resonance Imaging is beyond acceptable levels.

Keywords

  • image fusion
  • magnetic resonance imaging
  • gamma knife radiosurgery
  • computed tomography
Open Access

Estimating mental fatigue based on electroencephalogram and heart rate variability

Published Online: 05 May 2011
Page range: 67 - 84

Abstract

Estimating mental fatigue based on electroencephalogram and heart rate variability

The effects of long term mental arithmetic task on psychology are investigated by subjective self-reporting measures and action performance test. Based on electroencephalogram (EEG) and heart rate variability (HRV), the impacts of prolonged cognitive activity on central nervous system and autonomic nervous system are observed and analyzed. Wavelet packet parameters of EEG and power spectral indices of HRV are combined to estimate the change of mental fatigue. Then wavelet packet parameters of EEG which change significantly are extracted as the features of brain activity in different mental fatigue state, support vector machine (SVM) algorithm is applied to differentiate two mental fatigue states. The experimental results show that long term mental arithmetic task induces the mental fatigue. The wavelet packet parameters of EEG and power spectral indices of HRV are strongly correlated with mental fatigue. The predominant activity of autonomic nervous system of subjects turns to the sympathetic activity from parasympathetic activity after the task. Moreover, the slow waves of EEG increase, the fast waves of EEG and the degree of disorder of brain decrease compared with the pre-task. The SVM algorithm can effectively differentiate two mental fatigue states, which achieves the maximum classification accuracy (91%). The SVM algorithm could be a promising tool for the evaluation of mental fatigue.

Fatigue, especially mental fatigue, is a common phenomenon in modern life, is a persistent occupational hazard for professional. Mental fatigue is usually accompanied with a sense of weariness, reduced alertness, and reduced mental performance, which would lead the accidents in life, decrease productivity in workplace and harm the health. Therefore, the evaluation of mental fatigue is important for the occupational risk protection, productivity, and occupational health.

Keywords

  • mental fatigue
  • Electroencephalogram (EEG)
  • heart rate variability (HRV)
  • wavelet packet parameters
  • power spectral
  • support vector machine (SVM)
Open Access

Study of dosimetric variation due to interfraction organ movement in High Dose Rate Interstital (MUPIT) brachytherapy for gynecologic malignancies

Published Online: 05 May 2011
Page range: 85 - 95

Abstract

Study of dosimetric variation due to interfraction organ movement in High Dose Rate Interstital (MUPIT) brachytherapy for gynecologic malignancies

Ten patients with cancer of uterine cervix who underwent interstitial brachytherapy using MUPIT templates were CT scanned (CT1) using which bladder, rectum and CTV were delineated. The treatment plan PCT1 was generated and optimized geometrically on the volume. CT scan (CT2) was repeated before the second fraction of the treatment CTV and critical organs were delineated. The plan (PCT2) was created by reproducing the Plan PCT1 in the CT2 images and compared with PCT1. Bladder, Rectum and CTV percentage volume variation ranges from +28.6% to -34.3%, 38.4% to -14.9% and 8.5% to -15.2% respectively. Maximum dose variation in bladder was +17.1%, in rectum was up to +410% and in CTV was -13.0%. The dose to these structures varies independently with no strong correlation with the volume variation. Hence it is suggested that repeat CT and re-planning is mandatory before second fraction execution.

Keywords

  • interstitial brachytherapy
  • MUPIT implant
  • inter-fraction dose variation
Open Access

Baseline survey of level of quality control in medical radiology in Cross River State, Nigeria

Published Online: 05 May 2011
Page range: 97 - 106

Abstract

Baseline survey of level of quality control in medical radiology in Cross River State, Nigeria

Quality control (QC) in radiology is meant to ensure that accurate diagnoses are obtained with radiation doses kept as low as reasonably achievable. It is also a fundamental requirement by the Regulatory Authorities in issuing operational license to operators of radiology facilities. In Nigeria, QC issues in Radiation Medicine have recently been introduced and are being enforced by the Nigerian Nuclear Regulatory Authority (NNRA). The level of QC practice in the radiology facilities in Cross River State, Nigeria was evaluated to obtain baseline information that could be relied on in the future to determine the level of improvement. It was observed that radiology practitioners appreciate QC and its importance in their practice, the present low level of its implementation notwithstanding.

Keywords

  • quality control
  • diagnostic radiology
  • baseline
  • license
  • regulatory control
Open Access

Application of a PExSim for modeling a POLVAD artificial heart and the human circulatory system with left ventricle assistance

Published Online: 05 May 2011
Page range: 107 - 124

Abstract

Application of a PExSim for modeling a POLVAD artificial heart and the human circulatory system with left ventricle assistance

This paper presents a model of the human circulatory system with the possible addition of a parallel assist device, which was developed for the purpose of artificial heart monitoring. Information about an identification experiment of an extracorporeal ventricle assist device POLVAD is included. The modelling methods applied and the corresponding functional blocks in a PExSim package are presented. The results of the simulation for physiological conditions, left ventricle failure and pathological conditions with parallel assistance are included.

Keywords

  • PExSim
  • modeling of the ventricular assist device
  • POLVAD
  • modeling of the circulatory system
0 Articles
Open Access

A novel technique to evaluate the geometrical accuracy of CT-MR image fusion in Gamma Knife radiosurgery procedures

Published Online: 05 May 2011
Page range: 55 - 66

Abstract

A novel technique to evaluate the geometrical accuracy of CT-MR image fusion in Gamma Knife radiosurgery procedures

In order to optimize the accuracy of imaging in Gamma Knife radiosurgery using the image fusion options available in the Leksell gamma plan. Phantom images from 1.5 Tesla MRI Scan (Magnetom vision - Siemens) and Computed Tomography images from Philips Brilliance 16 CT scanner were used for image fusion in Gammaplan treatment planning system. The images were fused using co-registration technique using multiview and imagemerge modules. Stereotactic coordinates were then calculated for known targets. Vector distances from the centre of the Leksell coordinate system to five known targets were measured in CT, MR and CT-MR fused images and compared with geometrical measurements. The mean values of maximum absolute errors were 0.34 mm, 0.41 mm.0.38 mm (along x-axis), 0.43 mm, 1.53 mm, 0.62 mm (along y-axis) and 0.75 mm 2.02 mm, 0.93 mm (along z-axis) for CT, MR and CT-MR fused image data respectively. The mean error in calculating the vector distances from the center of the Leksell coordinate system (100, 100, 100) to the known target volumes are 0.22 mm, 0.8 mm and 0.43 mm for CT, MR and CT-MR fused images, respectively. Image fusion functions available in gamma plan are useful for combining the features of CT and MR imaging modalities. These methods are highly useful in clinical situations where the error associated with Magnetic Resonance Imaging is beyond acceptable levels.

Keywords

  • image fusion
  • magnetic resonance imaging
  • gamma knife radiosurgery
  • computed tomography
Open Access

Estimating mental fatigue based on electroencephalogram and heart rate variability

Published Online: 05 May 2011
Page range: 67 - 84

Abstract

Estimating mental fatigue based on electroencephalogram and heart rate variability

The effects of long term mental arithmetic task on psychology are investigated by subjective self-reporting measures and action performance test. Based on electroencephalogram (EEG) and heart rate variability (HRV), the impacts of prolonged cognitive activity on central nervous system and autonomic nervous system are observed and analyzed. Wavelet packet parameters of EEG and power spectral indices of HRV are combined to estimate the change of mental fatigue. Then wavelet packet parameters of EEG which change significantly are extracted as the features of brain activity in different mental fatigue state, support vector machine (SVM) algorithm is applied to differentiate two mental fatigue states. The experimental results show that long term mental arithmetic task induces the mental fatigue. The wavelet packet parameters of EEG and power spectral indices of HRV are strongly correlated with mental fatigue. The predominant activity of autonomic nervous system of subjects turns to the sympathetic activity from parasympathetic activity after the task. Moreover, the slow waves of EEG increase, the fast waves of EEG and the degree of disorder of brain decrease compared with the pre-task. The SVM algorithm can effectively differentiate two mental fatigue states, which achieves the maximum classification accuracy (91%). The SVM algorithm could be a promising tool for the evaluation of mental fatigue.

Fatigue, especially mental fatigue, is a common phenomenon in modern life, is a persistent occupational hazard for professional. Mental fatigue is usually accompanied with a sense of weariness, reduced alertness, and reduced mental performance, which would lead the accidents in life, decrease productivity in workplace and harm the health. Therefore, the evaluation of mental fatigue is important for the occupational risk protection, productivity, and occupational health.

Keywords

  • mental fatigue
  • Electroencephalogram (EEG)
  • heart rate variability (HRV)
  • wavelet packet parameters
  • power spectral
  • support vector machine (SVM)
Open Access

Study of dosimetric variation due to interfraction organ movement in High Dose Rate Interstital (MUPIT) brachytherapy for gynecologic malignancies

Published Online: 05 May 2011
Page range: 85 - 95

Abstract

Study of dosimetric variation due to interfraction organ movement in High Dose Rate Interstital (MUPIT) brachytherapy for gynecologic malignancies

Ten patients with cancer of uterine cervix who underwent interstitial brachytherapy using MUPIT templates were CT scanned (CT1) using which bladder, rectum and CTV were delineated. The treatment plan PCT1 was generated and optimized geometrically on the volume. CT scan (CT2) was repeated before the second fraction of the treatment CTV and critical organs were delineated. The plan (PCT2) was created by reproducing the Plan PCT1 in the CT2 images and compared with PCT1. Bladder, Rectum and CTV percentage volume variation ranges from +28.6% to -34.3%, 38.4% to -14.9% and 8.5% to -15.2% respectively. Maximum dose variation in bladder was +17.1%, in rectum was up to +410% and in CTV was -13.0%. The dose to these structures varies independently with no strong correlation with the volume variation. Hence it is suggested that repeat CT and re-planning is mandatory before second fraction execution.

Keywords

  • interstitial brachytherapy
  • MUPIT implant
  • inter-fraction dose variation
Open Access

Baseline survey of level of quality control in medical radiology in Cross River State, Nigeria

Published Online: 05 May 2011
Page range: 97 - 106

Abstract

Baseline survey of level of quality control in medical radiology in Cross River State, Nigeria

Quality control (QC) in radiology is meant to ensure that accurate diagnoses are obtained with radiation doses kept as low as reasonably achievable. It is also a fundamental requirement by the Regulatory Authorities in issuing operational license to operators of radiology facilities. In Nigeria, QC issues in Radiation Medicine have recently been introduced and are being enforced by the Nigerian Nuclear Regulatory Authority (NNRA). The level of QC practice in the radiology facilities in Cross River State, Nigeria was evaluated to obtain baseline information that could be relied on in the future to determine the level of improvement. It was observed that radiology practitioners appreciate QC and its importance in their practice, the present low level of its implementation notwithstanding.

Keywords

  • quality control
  • diagnostic radiology
  • baseline
  • license
  • regulatory control
Open Access

Application of a PExSim for modeling a POLVAD artificial heart and the human circulatory system with left ventricle assistance

Published Online: 05 May 2011
Page range: 107 - 124

Abstract

Application of a PExSim for modeling a POLVAD artificial heart and the human circulatory system with left ventricle assistance

This paper presents a model of the human circulatory system with the possible addition of a parallel assist device, which was developed for the purpose of artificial heart monitoring. Information about an identification experiment of an extracorporeal ventricle assist device POLVAD is included. The modelling methods applied and the corresponding functional blocks in a PExSim package are presented. The results of the simulation for physiological conditions, left ventricle failure and pathological conditions with parallel assistance are included.

Keywords

  • PExSim
  • modeling of the ventricular assist device
  • POLVAD
  • modeling of the circulatory system