Accuracy of transthoracic echocardiography in diagnosis of cardiac myxoma: single center experience
, , , oraz
22 sty 2025
O artykule
Kategoria artykułu: research article
Data publikacji: 22 sty 2025
Zakres stron: 63 - 68
Otrzymano: 10 lut 2024
Przyjęty: 08 gru 2024
DOI: https://doi.org/10.2478/raon-2025-0007
Słowa kluczowe
© 2025 Polona Kacar et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
FIGURE 1.

FIGURE 2.

Comparison of demographic and echocardiographic characteristics between pathohistologically confirmed cardiac myxoma (CM) and non-myxoma (NM) groups
Characteristic | CM (n= 39) | NM (n = 14) | p value |
---|---|---|---|
Age (years) | 63.1 ± 13.6 | 66.6 ± 15.1 | 0.434 |
Sex (female) | 25 (64) | 10 (71) | 0.620 |
Location | |||
Typical | 28 (72) | 0 | P < 0.001 |
Atypical | 11 (28) | 14 (100) | P < 0.001 |
Size (mm) | 37.9 ± 18.3 | 24.3 ± 13.2 | 0.017 |
Preoperative echocardiographic characteristics of the cardiac myxoma (CM) and non-myxoma (NM) group
Echocardiographic characteristics | CM (n=45) | NM (n =8) |
---|---|---|
Mean size (mm) | 35.3 ± 18.6 (range: 10–81) | 30.3 ± 16.9 (range: 8–50) |
Location | ||
Left atrium | 36 (80) | 2 (25) |
Fossa ovalis | 27 (75) | |
Mitral valve | 4 (11) | 1 (50) |
Posterior interatrial septum | 3 (8) | |
Free left atrial wall | 1 (3) | 1 (50) |
Left atrial appendage | 1 (3) | |
Right atrium | 8 (18) | 4 (50) |
Left ventricle | 1 (2) | 1 (12) |
Aortic valve | 1 (12) | |
Mobility | ||
Mobile | 32 (71) | 7 (88) |
Non-mobile | 5 (11) | |
No data available | 8 (18) | 1 (12) |
Surface | ||
Smooth or lobulated | 28 (62) | 1 (12) |
Villous | 8 (18) | 3 (38) |
No data available | 9 (20) | 4 (50) |
Obstruction (present) | 11 (24) | 2 (25) |
Mitral valve | 10 (21) | 1 (50) |