Accuracy of transthoracic echocardiography in diagnosis of cardiac myxoma: single center experience
, , , y
22 ene 2025
Acerca de este artículo
Categoría del artículo: research article
Publicado en línea: 22 ene 2025
Páginas: 63 - 68
Recibido: 10 feb 2024
Aceptado: 08 dic 2024
DOI: https://doi.org/10.2478/raon-2025-0007
Palabras clave
© 2025 Polona Kacar et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
FIGURE 1.

FIGURE 2.

Comparison of demographic and echocardiographic characteristics between pathohistologically confirmed cardiac myxoma (CM) and non-myxoma (NM) groups
Characteristic | CM (n= 39) | NM (n = 14) | p value |
---|---|---|---|
Age (years) | 63.1 ± 13.6 | 66.6 ± 15.1 | 0.434 |
Sex (female) | 25 (64) | 10 (71) | 0.620 |
Location | |||
Typical | 28 (72) | 0 | P < 0.001 |
Atypical | 11 (28) | 14 (100) | P < 0.001 |
Size (mm) | 37.9 ± 18.3 | 24.3 ± 13.2 | 0.017 |
Preoperative echocardiographic characteristics of the cardiac myxoma (CM) and non-myxoma (NM) group
Echocardiographic characteristics | CM (n=45) | NM (n =8) |
---|---|---|
Mean size (mm) | 35.3 ± 18.6 (range: 10–81) | 30.3 ± 16.9 (range: 8–50) |
Location | ||
Left atrium | 36 (80) | 2 (25) |
Fossa ovalis | 27 (75) | |
Mitral valve | 4 (11) | 1 (50) |
Posterior interatrial septum | 3 (8) | |
Free left atrial wall | 1 (3) | 1 (50) |
Left atrial appendage | 1 (3) | |
Right atrium | 8 (18) | 4 (50) |
Left ventricle | 1 (2) | 1 (12) |
Aortic valve | 1 (12) | |
Mobility | ||
Mobile | 32 (71) | 7 (88) |
Non-mobile | 5 (11) | |
No data available | 8 (18) | 1 (12) |
Surface | ||
Smooth or lobulated | 28 (62) | 1 (12) |
Villous | 8 (18) | 3 (38) |
No data available | 9 (20) | 4 (50) |
Obstruction (present) | 11 (24) | 2 (25) |
Mitral valve | 10 (21) | 1 (50) |
Tricuspid valve | 1 (9) | 1 (50) |