Zeszyty czasopisma

Tom 23 (2023): Zeszyt 1 (February 2023)

Tom 22 (2022): Zeszyt 6 (December 2022)

Tom 22 (2022): Zeszyt 5 (October 2022)

Tom 22 (2022): Zeszyt 4 (August 2022)

Tom 22 (2022): Zeszyt 3 (June 2022)

Tom 22 (2022): Zeszyt 2 (April 2022)

Tom 22 (2022): Zeszyt 1 (February 2022)

Tom 21 (2021): Zeszyt 6 (December 2021)

Tom 21 (2021): Zeszyt 5 (October 2021)

Tom 21 (2021): Zeszyt 4 (August 2021)

Tom 21 (2021): Zeszyt 3 (June 2021)

Tom 21 (2021): Zeszyt 2 (April 2021)

Tom 21 (2021): Zeszyt 1 (February 2021)

Tom 20 (2020): Zeszyt 5 (October 2020)

Tom 20 (2020): Zeszyt 4 (August 2020)

Tom 20 (2020): Zeszyt 3 (June 2020)

Tom 20 (2020): Zeszyt 2 (April 2020)

Tom 20 (2020): Zeszyt 1 (February 2020)

Tom 19 (2019): Zeszyt 6 (December 2019)

Tom 19 (2019): Zeszyt 5 (October 2019)

Tom 19 (2019): Zeszyt 4 (August 2019)

Tom 19 (2019): Zeszyt 3 (June 2019)

Tom 19 (2019): Zeszyt 2 (April 2019)

Tom 19 (2019): Zeszyt 1 (February 2019)

Tom 18 (2018): Zeszyt 6 (October 2018)

Tom 18 (2018): Zeszyt 5 (October 2018)

Tom 18 (2018): Zeszyt 4 (August 2018)

Tom 18 (2018): Zeszyt 3 (June 2018)

Tom 18 (2018): Zeszyt 2 (April 2018)

Tom 18 (2018): Zeszyt 1 (February 2018)

Tom 17 (2017): Zeszyt 6 (December 2017)

Tom 17 (2017): Zeszyt 5 (October 2017)

Tom 17 (2017): Zeszyt 3 (June 2017)

Tom 17 (2017): Zeszyt 2 (April 2017)

Tom 17 (2017): Zeszyt 1 (February 2017)

Tom 16 (2016): Zeszyt 6 (December 2016)

Tom 16 (2016): Zeszyt 5 (October 2016)

Tom 16 (2016): Zeszyt 4 (August 2016)

Tom 16 (2016): Zeszyt 3 (June 2016)

Tom 16 (2016): Zeszyt 2 (April 2016)

Tom 16 (2016): Zeszyt 1 (February 2016)

Tom 15 (2015): Zeszyt 6 (December 2015)

Tom 15 (2015): Zeszyt 5 (October 2015)

Tom 15 (2015): Zeszyt 4 (August 2015)

Tom 15 (2015): Zeszyt 3 (June 2015)

Tom 15 (2015): Zeszyt 2 (April 2015)

Tom 15 (2015): Zeszyt 1 (February 2015)

Tom 14 (2014): Zeszyt 6 (December 2014)

Tom 14 (2014): Zeszyt 5 (October 2014)

Tom 14 (2014): Zeszyt 4 (August 2014)

Tom 14 (2014): Zeszyt 3 (June 2014)

Tom 14 (2014): Zeszyt 2 (April 2014)

Tom 14 (2014): Zeszyt 1 (February 2014)

Tom 13 (2013): Zeszyt 6 (December 2013)

Tom 13 (2013): Zeszyt 5 (October 2013)

Tom 13 (2013): Zeszyt 4 (August 2013)

Tom 13 (2013): Zeszyt 3 (June 2013)

Tom 13 (2013): Zeszyt 2 (April 2013)

Tom 13 (2013): Zeszyt 1 (February 2013)

Tom 12 (2012): Zeszyt 6 (December 2012)

Tom 12 (2012): Zeszyt 5 (October 2012)

Tom 12 (2012): Zeszyt 4 (August 2012)

Tom 12 (2012): Zeszyt 3 (June 2012)

Tom 12 (2012): Zeszyt 2 (April 2012)

Tom 12 (2012): Zeszyt 1 (February 2012)

Tom 11 (2011): Zeszyt 6 (December 2011)

Tom 11 (2011): Zeszyt 5 (October 2011)

Tom 11 (2011): Zeszyt 4 (August 2011)

Tom 11 (2011): Zeszyt 3 (June 2011)

Tom 11 (2011): Zeszyt 2 (April 2011)

Tom 11 (2011): Zeszyt 1 (February 2011)

Tom 10 (2010): Zeszyt 6 (December 2010)

Tom 10 (2010): Zeszyt 5 (October 2010)

Tom 10 (2010): Zeszyt 4 (August 2010)

Tom 10 (2010): Zeszyt 3 (June 2010)

Tom 10 (2010): Zeszyt 2 (April 2010)

Tom 10 (2010): Zeszyt 1 (February 2010)

Tom 9 (2009): Zeszyt 6 (December 2009)

Tom 9 (2009): Zeszyt 5 (October 2009)

Tom 9 (2009): Zeszyt 4 (August 2009)

Tom 9 (2009): Zeszyt 3 (June 2009)

Tom 9 (2009): Zeszyt 2 (April 2009)

Tom 9 (2009): Zeszyt 1 (February 2009)

Tom 8 (2008): Zeszyt 6 (December 2008)

Tom 8 (2008): Zeszyt 5 (October 2008)

Tom 8 (2008): Zeszyt 4 (August 2008)

Tom 8 (2008): Zeszyt 3 (June 2008)

Tom 8 (2008): Zeszyt 2 (April 2008)

Tom 8 (2008): Zeszyt 1 (February 2008)

Informacje o czasopiśmie
Format
Czasopismo
eISSN
1335-8871
Pierwsze wydanie
07 Mar 2008
Częstotliwość wydawania
6 razy w roku
Języki
Angielski

Wyszukiwanie

Tom 18 (2018): Zeszyt 2 (April 2018)

Informacje o czasopiśmie
Format
Czasopismo
eISSN
1335-8871
Pierwsze wydanie
07 Mar 2008
Częstotliwość wydawania
6 razy w roku
Języki
Angielski

Wyszukiwanie

6 Artykułów
Otwarty dostęp

Generation of Long-time Complex Signals for Testing the Instruments for Detection of Voltage Quality Disturbances

Data publikacji: 04 Apr 2018
Zakres stron: 41 - 51

Abstrakt

Abstract

Software supported procedure for generation of long-time complex test sentences, suitable for testing the instruments for detection of standard voltage quality (VQ) disturbances is presented in this paper. This solution for test signal generation includes significant improvements of computer-based signal generator presented and described in the previously published paper [1]. The generator is based on virtual instrumentation software for defining the basic signal parameters, data acquisition card NI 6343, and power amplifier for amplification of output voltage level to the nominal RMS voltage value of 230 V. Definition of basic signal parameters in LabVIEW application software is supported using Script files, which allows simple repetition of specific test signals and combination of more different test sequences in the complex composite test waveform. The basic advantage of this generator compared to the similar solutions for signal generation is the possibility for long-time test sequence generation according to predefined complex test scenarios, including various combinations of VQ disturbances defined in accordance with the European standard EN50160. Experimental verification of the presented signal generator capability is performed by testing the commercial power quality analyzer Fluke 435 Series II. In this paper are shown some characteristic complex test signals with various disturbances and logged data obtained from the tested power quality analyzer.

Słowa kluczowe

  • Signal generation
  • instrument testing
  • voltage quality disturbances
  • LabVIEW software
Otwarty dostęp

Metrological Software Test for Simulating the Method of Determining the Thermocouple Error in Situ During Operation

Data publikacji: 04 Apr 2018
Zakres stron: 52 - 58

Abstrakt

Abstract

The simplified metrological software test (MST) for modeling the method of determining the thermocouple (TC) error in situ during operation is considered in the paper. The interaction between the proposed MST and a temperature measuring system is also reflected in order to study the error of determining the TC error in situ during operation. The modelling studies of the random error influence of the temperature measuring system, as well as interference magnitude (both the common and normal mode noises) on the error of determining the TC error in situ during operation using the proposed MST, have been carried out. The noise and interference of the order of 5-6 μV cause the error of about 0.2-0.3°C. It is shown that high noise immunity is essential for accurate temperature measurements using TCs.

Słowa kluczowe

  • Thermocouple
  • determination of TC error in situ
  • determination of TC error during operation
  • metrological software test
  • simulation of measuring channel
Otwarty dostęp

Analysis and Calculation of the Fluid Flow and the Temperature Field by Finite Element Modeling

Data publikacji: 04 Apr 2018
Zakres stron: 59 - 64

Abstrakt

Abstract

This paper presents a fundamental and accurate approach to study numerical analysis of fluid flow and heat transfer inside a channel. In this study, the Finite Element Method is used to analyze the channel, which is divided into small subsections. The small subsections are discretized using higher number of domain elements and the corresponding number of nodes. MATLAB codes are developed to be used in the analysis. Simulation results showed that the analyses of fluid flow and temperature are influenced significantly by the changing entrance velocity. Also, there is an apparent effect on the temperature fields due to the presence of an energy source in the middle of the domain. In this paper, the characteristics of flow analysis and heat analysis in a channel have been investigated.

Słowa kluczowe

  • Finite Element Method
  • flow analysis
  • temperature analysis
  • entrance velocity
  • simulation
Otwarty dostęp

High Precision Edge Detection Algorithm for Mechanical Parts

Data publikacji: 04 Apr 2018
Zakres stron: 65 - 71

Abstrakt

Abstract

High precision and high efficiency measurement is becoming an imperative requirement for a lot of mechanical parts. So in this study, a subpixel-level edge detection algorithm based on the Gaussian integral model is proposed. For this purpose, the step edge normal section line Gaussian integral model of the backlight image is constructed, combined with the point spread function and the single step model. Then gray value of discrete points on the normal section line of pixel edge is calculated by surface interpolation, and the coordinate as well as gray information affected by noise is fitted in accordance with the Gaussian integral model. Therefore, a precise location of a subpixel edge was determined by searching the mean point. Finally, a gear tooth was measured by M&M3525 gear measurement center to verify the proposed algorithm. The theoretical analysis and experimental results show that the local edge fluctuation is reduced effectively by the proposed method in comparison with the existing subpixel edge detection algorithms. The subpixel edge location accuracy and computation speed are improved. And the maximum error of gear tooth profile total deviation is 1.9 μm compared with measurement result with gear measurement center. It indicates that the method has high reliability to meet the requirement of high precision measurement.

Słowa kluczowe

  • Vision measurement
  • edge detection
  • subpixel-level
  • Gaussian integral model
  • normal section line
Otwarty dostęp

The Influence of Measurement Methodology on the Accuracy of Electrical Waveform Distortion Analysis

Data publikacji: 04 Apr 2018
Zakres stron: 72 - 78

Abstrakt

Abstract

The present paper covers a review of documents that specify measurement methods of voltage waveform distortion. It also presents measurement stages of waveform components that are uncommon in the classic fundamentals of electrotechnics and signal theory, including the creation process of groups and subgroups of harmonics and interharmonics. Moreover, the paper discusses selected distortion factors of periodic waveforms and presents analyses that compare the values of these distortion indices. The measurements were carried out in the cycle per cycle mode and the measurement methodology that was used complies with the IEC 61000-4-7 norm. The studies showed significant discrepancies between the values of analyzed parameters.

Słowa kluczowe

  • Distortion measurement
  • harmonic analysis
  • inverters
  • IEC standards
  • factors of waveforms distortion
Otwarty dostęp

A Novel Marker Based Method to Teeth Alignment in MRI

Data publikacji: 04 Apr 2018
Zakres stron: 79 - 85

Abstrakt

Abstract

Magnetic resonance imaging (MRI) can precisely capture the anatomy of the vocal tract. However, the crowns of teeth are not visible in standard MRI scans. In this study, a marker-based teeth alignment method is presented and evaluated. Ten patients undergoing orthognathic surgery were enrolled. Supraglottal airways were imaged preoperatively using structural MRI. MRI visible markers were developed, and they were attached to maxillary teeth and corresponding locations on the dental casts. Repeated measurements of intermarker distances in MRI and in a replica model was compared using linear regression analysis. Dental cast MRI and corresponding caliper measurements did not differ significantly. In contrast, the marker locations in vivo differed somewhat from the dental cast measurements likely due to marker placement inaccuracies. The markers were clearly visible in MRI and allowed for dental models to be aligned to head and neck MRI scans.

Słowa kluczowe

  • Dental imaging
  • Magnetic resonance imaging
  • MRI markers
  • teeth superposition
  • vocal tract imaging
6 Artykułów
Otwarty dostęp

Generation of Long-time Complex Signals for Testing the Instruments for Detection of Voltage Quality Disturbances

Data publikacji: 04 Apr 2018
Zakres stron: 41 - 51

Abstrakt

Abstract

Software supported procedure for generation of long-time complex test sentences, suitable for testing the instruments for detection of standard voltage quality (VQ) disturbances is presented in this paper. This solution for test signal generation includes significant improvements of computer-based signal generator presented and described in the previously published paper [1]. The generator is based on virtual instrumentation software for defining the basic signal parameters, data acquisition card NI 6343, and power amplifier for amplification of output voltage level to the nominal RMS voltage value of 230 V. Definition of basic signal parameters in LabVIEW application software is supported using Script files, which allows simple repetition of specific test signals and combination of more different test sequences in the complex composite test waveform. The basic advantage of this generator compared to the similar solutions for signal generation is the possibility for long-time test sequence generation according to predefined complex test scenarios, including various combinations of VQ disturbances defined in accordance with the European standard EN50160. Experimental verification of the presented signal generator capability is performed by testing the commercial power quality analyzer Fluke 435 Series II. In this paper are shown some characteristic complex test signals with various disturbances and logged data obtained from the tested power quality analyzer.

Słowa kluczowe

  • Signal generation
  • instrument testing
  • voltage quality disturbances
  • LabVIEW software
Otwarty dostęp

Metrological Software Test for Simulating the Method of Determining the Thermocouple Error in Situ During Operation

Data publikacji: 04 Apr 2018
Zakres stron: 52 - 58

Abstrakt

Abstract

The simplified metrological software test (MST) for modeling the method of determining the thermocouple (TC) error in situ during operation is considered in the paper. The interaction between the proposed MST and a temperature measuring system is also reflected in order to study the error of determining the TC error in situ during operation. The modelling studies of the random error influence of the temperature measuring system, as well as interference magnitude (both the common and normal mode noises) on the error of determining the TC error in situ during operation using the proposed MST, have been carried out. The noise and interference of the order of 5-6 μV cause the error of about 0.2-0.3°C. It is shown that high noise immunity is essential for accurate temperature measurements using TCs.

Słowa kluczowe

  • Thermocouple
  • determination of TC error in situ
  • determination of TC error during operation
  • metrological software test
  • simulation of measuring channel
Otwarty dostęp

Analysis and Calculation of the Fluid Flow and the Temperature Field by Finite Element Modeling

Data publikacji: 04 Apr 2018
Zakres stron: 59 - 64

Abstrakt

Abstract

This paper presents a fundamental and accurate approach to study numerical analysis of fluid flow and heat transfer inside a channel. In this study, the Finite Element Method is used to analyze the channel, which is divided into small subsections. The small subsections are discretized using higher number of domain elements and the corresponding number of nodes. MATLAB codes are developed to be used in the analysis. Simulation results showed that the analyses of fluid flow and temperature are influenced significantly by the changing entrance velocity. Also, there is an apparent effect on the temperature fields due to the presence of an energy source in the middle of the domain. In this paper, the characteristics of flow analysis and heat analysis in a channel have been investigated.

Słowa kluczowe

  • Finite Element Method
  • flow analysis
  • temperature analysis
  • entrance velocity
  • simulation
Otwarty dostęp

High Precision Edge Detection Algorithm for Mechanical Parts

Data publikacji: 04 Apr 2018
Zakres stron: 65 - 71

Abstrakt

Abstract

High precision and high efficiency measurement is becoming an imperative requirement for a lot of mechanical parts. So in this study, a subpixel-level edge detection algorithm based on the Gaussian integral model is proposed. For this purpose, the step edge normal section line Gaussian integral model of the backlight image is constructed, combined with the point spread function and the single step model. Then gray value of discrete points on the normal section line of pixel edge is calculated by surface interpolation, and the coordinate as well as gray information affected by noise is fitted in accordance with the Gaussian integral model. Therefore, a precise location of a subpixel edge was determined by searching the mean point. Finally, a gear tooth was measured by M&M3525 gear measurement center to verify the proposed algorithm. The theoretical analysis and experimental results show that the local edge fluctuation is reduced effectively by the proposed method in comparison with the existing subpixel edge detection algorithms. The subpixel edge location accuracy and computation speed are improved. And the maximum error of gear tooth profile total deviation is 1.9 μm compared with measurement result with gear measurement center. It indicates that the method has high reliability to meet the requirement of high precision measurement.

Słowa kluczowe

  • Vision measurement
  • edge detection
  • subpixel-level
  • Gaussian integral model
  • normal section line
Otwarty dostęp

The Influence of Measurement Methodology on the Accuracy of Electrical Waveform Distortion Analysis

Data publikacji: 04 Apr 2018
Zakres stron: 72 - 78

Abstrakt

Abstract

The present paper covers a review of documents that specify measurement methods of voltage waveform distortion. It also presents measurement stages of waveform components that are uncommon in the classic fundamentals of electrotechnics and signal theory, including the creation process of groups and subgroups of harmonics and interharmonics. Moreover, the paper discusses selected distortion factors of periodic waveforms and presents analyses that compare the values of these distortion indices. The measurements were carried out in the cycle per cycle mode and the measurement methodology that was used complies with the IEC 61000-4-7 norm. The studies showed significant discrepancies between the values of analyzed parameters.

Słowa kluczowe

  • Distortion measurement
  • harmonic analysis
  • inverters
  • IEC standards
  • factors of waveforms distortion
Otwarty dostęp

A Novel Marker Based Method to Teeth Alignment in MRI

Data publikacji: 04 Apr 2018
Zakres stron: 79 - 85

Abstrakt

Abstract

Magnetic resonance imaging (MRI) can precisely capture the anatomy of the vocal tract. However, the crowns of teeth are not visible in standard MRI scans. In this study, a marker-based teeth alignment method is presented and evaluated. Ten patients undergoing orthognathic surgery were enrolled. Supraglottal airways were imaged preoperatively using structural MRI. MRI visible markers were developed, and they were attached to maxillary teeth and corresponding locations on the dental casts. Repeated measurements of intermarker distances in MRI and in a replica model was compared using linear regression analysis. Dental cast MRI and corresponding caliper measurements did not differ significantly. In contrast, the marker locations in vivo differed somewhat from the dental cast measurements likely due to marker placement inaccuracies. The markers were clearly visible in MRI and allowed for dental models to be aligned to head and neck MRI scans.

Słowa kluczowe

  • Dental imaging
  • Magnetic resonance imaging
  • MRI markers
  • teeth superposition
  • vocal tract imaging

Zaplanuj zdalną konferencję ze Sciendo