High-Dimensional Feature Optimization and Real-Time Prediction Model with Support Vector Machines for Fault Diagnosis of Electrical Equipment
oraz
19 mar 2025
O artykule
Data publikacji: 19 mar 2025
Otrzymano: 25 paź 2024
Przyjęty: 03 lut 2025
DOI: https://doi.org/10.2478/amns-2025-0480
Słowa kluczowe
© 2025 Lei Li et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Figure 9.

Figure 10.

Figure 11.

Figure 12.

Figure 13.

After using the model presented in this article
Prediction fault type | ||||||
---|---|---|---|---|---|---|
Actual fault type | ||||||
523 | 0 | 27 | 0 | 0 | ||
0 | 550 | 0 | 0 | 0 | ||
63 | 0 | 205 | 5 | 277 | ||
78 | 0 | 134 | 275 | 63 | ||
65 | 0 | 278 | 32 | 175 |
The prediction of ammonia in different dimensions
Dimension m | Parameter C | Parameter g | Parameter |
Parameter optimization error |
---|---|---|---|---|
2 | 6 | 220.3 | 0.000945 | 0.25 |
3 | 25.6 | 125.4 | 0.08 | 0.18 |
4 | 9.5 | 255.1 | 0.000945 | 0.344 |
5 | 72.14 | 46.8 | 0.145 | 0.0051 |
6 | 55.31 | 91.3 | 0.000945 | 0.00241 |
7 | 53.64 | 75.6 | 0.00088 | 0.00575 |
Transformer fault characteristic gas data(μL/L)
Time | H2 | C2H6 | C2H2 | C2H4 | CH4 |
---|---|---|---|---|---|
Supplementary data | 22.1 | 110.1 | 0 | 67.6 | 32 |
2022/08/11 | 22.3 | 109.2 | 0 | 67.8 | 31.6 |
2022/09/01 | 21.6 | 107.8 | 0 | 66.7 | 31.7 |
2022/09/08 | 21.1 | 106.7 | 0 | 66.6 | 31.2 |
2022/10/11 | 19.9 | 106.5 | 0 | 64.5 | 30.6 |
Supplementary data | 20.2 | 104.8 | 0 | 64.2 | 30.9 |
2022/12/25 | 18.2 | 103.9 | 0 | 62.6 | 30.5 |
Supplementary data | 19.1 | 104.7 | 0 | 62.9 | 30.5 |
Supplementary data | 18.8 | 103.7 | 0 | 63.4 | 30.4 |
2023/01/01 | 18.6 | 102.4 | 0 | 62.5 | 30.7 |
Supplementary data | 18.7 | 102.7 | 0 | 62.5 | 31 |
2023/02/12 | 18.7 | 102.5 | 0 | 61.9 | 30.2 |
Supplementary data | 19 | 103.9 | 0 | 62.5 | 31.6 |
2023/04/12 | 19.3 | 103.5 | 0 | 63 | 31.5 |
2023/05/01 | 19.5 | 103.8 | 0 | 63.2 | 31 |
Supplementary data | 19.6 | 101.9 | 0 | 63.5 | 29.5 |
Supplementary data | 19.9 | 102.5 | 0 | 63.2 | 31 |
2023/07/02 | 21.2 | 104.5 | 0 | 64.5 | 31.5 |
2023/08/11 | 21.2 | 105.1 | 0 | 64.2 | 31.5 |
2023/10/11 | 21.6 | 108.6 | 0 | 64.4 | 30 |
2024/01/01 | 21.9 | 110.6 | 0 | 65.3 | 32.6 |
2024/01/15 | 22 | 115.2 | 0 | 65.1 | 33.3 |
Test results
Name | Time | Actual value | SVR/BP Predictive value | RE% of SVR/BP | MAPE% of SVR/BP | |||
---|---|---|---|---|---|---|---|---|
H2 | 1.39 | 20.51 | 20.937 | 20.902 | 4.12 | 5.33 | 4.04 | 5.14 |
2.01 | 20.59 | 20.96 | 20.72 | -3.99 | 5.32 | |||
C2H6 | 0.67 | 111.8 | 111.503 | 111.812 | 0.66 | -0.079 | 1.925 | 0.301 |
1.89 | 113.52 | 112.57 | 112.43 | 1.91 | 1.46 | |||
C2H4 | 1.48 | 64.41 | 64.12 | 64.95 | 1.145 | -2.2 | 0.9975 | 1.735 |
2.31 | 64.89 | 64.285 | 64.89 | -0.59 | 2.9 | |||
CH4 | 0.98 | 31.86 | 32.122 | 31.924 | 2.5 | 3.6 | 2.502 | 3.43 |
2.47 | 31.6 | 31.74 | 32.18 | 1.184 | -3.19 |
Before using the model presented in this article
Prediction fault type | ||||||
---|---|---|---|---|---|---|
Actual fault type | ||||||
550 | 0 | 0 | 0 | 0 | ||
0 | 550 | 0 | 0 | 0 | ||
195 | 0 | 95 | 86 | 174 | ||
256 | 0 | 81 | 138 | 75 | ||
193 | 0 | 140 | 55 | 162 |