Development of Antimicrobial and Antistatic Textile for Industrial Air Management Systems
, , , oraz
18 paź 2023
O artykule
Kategoria artykułu: Research Article
Data publikacji: 18 paź 2023
Zakres stron: 75 - 82
DOI: https://doi.org/10.2478/ftee-2023-0038
Słowa kluczowe
© 2023 Łukasiewicz Research Network-Łódź Institute of Technology, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Fig. 1.

Fig. 2.

Antimicrobial activity test of the unwashed and washed textile fabric prepared – evaluation of bacterial and fungus growth
Sample identification | Activity | Reference cultures | Growth | Inhibition zone, mm | Efficacy |
---|---|---|---|---|---|
Before antimicrobial treatment | Antibacterial | ATCC 12228 | none | 0 | NE |
ATCC 25922 | none | 0 | NE | ||
ATCC 25923 | none | 0 | NE | ||
ATCC 13883 | none | 0 | NE | ||
ATCC 27853 | none | 0 | NE | ||
ATCC 12459 | none | 0 | NE | ||
Antifungal | ATCC 10231 | none | 0 | NE | |
Sample 0 | Antibacterial | ATCC 12228 | none | 8.1 | GE |
ATCC 25922 | none | 2.1 | GE | ||
ATCC 25923 | none | 7.0 | GE | ||
ATCC 13883 | none | 3.0 | GE | ||
ATCC 27853 | none | 3.8 | GE | ||
ATCC 12459 | none | 1.3 | GE | ||
Antifungal | ATCC 10231 | none | 1.8 | GE | |
Sample 1 | Antibacterial | ATCC 12228 | none | 1.3 | GE |
ATCC 25922 | none | 0 | GE | ||
ATCC 25923 | none | 1.1 | GE | ||
ATCC 13883 | none | 0 | GE | ||
ATCC 27853 | none | 0 | GE | ||
ATCC 12459 | none | 0 | GE | ||
Antifungal | ATCC 10231 | none | 0 | GE | |
Sample 2 | Antibacterial | ATCC 12228 | none | 0 | GE |
ATCC 25922 | none | 0 | GE | ||
ATCC 25923 | none | 0 | GE | ||
ATCC 13883 | none | 0 | GE | ||
ATCC 27853 | none | 0 | GE | ||
ATCC 12459 | none | 0 | GE | ||
Antifungal | ATCC 10231 | none | 0 | GE |
Assessment conditions of the antimicrobial and antifungal effect in the agar diffusion test
Mean value of inhibition zone (mm) | Growth |
Description | Assessment |
---|---|---|---|
> 1 |
None |
Inhibition zone exceeding 1 mm, no growth b) |
Good effect |
0 | Slight | No inhibition zone, only some restricted colonies, growth nearly totally suppressed d) | Limit of efficacy |
0 |
Moderate |
No inhibition zone, compared to the control growth reduced to half e) |
Insufficient effect |
Evaluation of the electrostatic action of the unwashed and washed textile fabric prepared
Samples | Resistance | Remarks | Recommendation |
---|---|---|---|
Without antimicrobial treatment | 1.75×1012 Ω | Higher than minimum compliance value according to the standard | Not applicable for protective textiles |
Antimicrobial treated and unwashed | 1.17×109 Ω | Good enough for this application as it is twice lower than the minimum compliance value | Could be used for non-washable systems only |
Antimicrobial treated and after 1st washing cycle | 2.38×109 Ω | On the limits of error with minimum possible | Cannot be used for protective textiles. |
Antimicrobial treated and after 2nd washing cycle | --- | Much higher than is required | Cannot be used for protective textiles. |