Assessment of Utilization Possibilities of Heat Conducted by Waste Gases Exhaust Pipe of SB 1.5 Drum Drier for Drying Wood Chips
, , , oraz
18 cze 2016
O artykule
Data publikacji: 18 cze 2016
Zakres stron: 195 - 203
Otrzymano: 01 wrz 2015
Przyjęty: 01 lis 2015
DOI: https://doi.org/10.1515/agriceng-2016-0020
Słowa kluczowe
© 2016 Mariusz Surma et al., published by De Gruyter Open
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Based on the exploitation research, the authors evaluated the possibilities of using the heat conducted through the side surface of the waste gases exhaust pipe of SB 1.5 drum drier for drying wood chips. According to the estimated calculations within one hour approximately 173 thousand of kJ of heat may be obtained from the external surface of the waste gases exhaust pipe with the height of 7 m and temperature of approximately 78°C which constitutes an equivalent of approximately 4 kilo of heating oil. In case the above mentioned heat source for drying wood chips in SPA 20 silo with a volume of 6800 kilo within 50% to 20% humidity is used, one may expect that the drying time will be approximately 100 hours.