Non-singular Fast Terminal Sliding Mode Control Integrated with Proportional Multi-Resonant-Based Controller for Multifunctional Grid-Tied LCL-Filtered Inverter
07 set 2025
INFORMAZIONI SU QUESTO ARTICOLO
Categoria dell'articolo: Research paper
Pubblicato online: 07 set 2025
Pagine: 257 - 270
Ricevuto: 26 feb 2025
Accettato: 03 lug 2025
DOI: https://doi.org/10.2478/pead-2025-0018
Parole chiave
© 2025 Amir Rabbani et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Figure 9.

Figure 10.

System parameters
System parameter | Symbol | Value |
---|---|---|
DC link voltage | 600 V | |
Grid voltage | 230 V (RMS) | |
Grid frequency | 50 Hz | |
Sampling rate | 0.2 μs | |
Inverter-side inductance | 1.74 mH | |
Grid-side inductance | 0.68 mH | |
Filter capacitance | 10 μF | |
Inductor’s resistance | 0.2 Ω | |
Coefficient of NFTSMC | 1.8, 1.3, 300, 1 | |
PMR gains | 10, 2,000, 2,000, 2,000 | |
Bands of the hysteresis function | h | 2,000 |
Comparison of the proposed system with other works
Reference | Proposed | |||
---|---|---|---|---|
Transient response performance | Very high | Very high | Medium | Very high |
Robustness | High | High | High | Very high |
PWM method | PWM | PWM | PWM | Hysteresis |
Switching frequency | 20 Khz | Not reported | 25.6 Khz | Not fixed |
Non-linear load performance | Very high | Very high | Very high | Very high |
Complexity | High | High | High | Low |
Computational burden | Very high | High | High | Low |
Best grid THD | 0.98 | 1.56 | Not reported | 0.33 |