Magazine et Edition

Volume 16 (2021): Edition 4 (December 2021)

Volume 16 (2021): Edition 3 (September 2021)

Volume 16 (2021): Edition 2 (June 2021)

Volume 16 (2021): Edition 1 (March 2021)

Volume 15 (2019): Edition 4 (December 2019)

Volume 15 (2019): Edition 3 (September 2019)

Volume 15 (2019): Edition 2 (June 2019)

Volume 15 (2019): Edition 1 (March 2019)

Volume 14 (2018): Edition 4 (December 2018)

Volume 14 (2018): Edition 3 (September 2018)

Volume 14 (2018): Edition 2 (June 2018)

Volume 14 (2018): Edition 1 (March 2018)

Volume 13 (2017): Edition 4 (December 2017)

Volume 13 (2017): Edition 3 (September 2017)

Volume 13 (2017): Edition 2 (June 2017)

Volume 13 (2017): Edition 1 (March 2017)

Volume 12 (2016): Edition 4 (December 2016)

Volume 12 (2016): Edition 3 (September 2016)

Volume 12 (2016): Edition 2 (June 2016)

Volume 12 (2016): Edition 1 (March 2016)

Volume 11 (2015): Edition 4 (December 2015)

Volume 11 (2015): Edition 3 (September 2015)

Volume 11 (2015): Edition 2 (May 2015)

Volume 11 (2015): Edition 1 (March 2015)

Volume 10 (2014): Edition 4 (December 2014)

Volume 10 (2014): Edition 3 (September 2014)

Volume 10 (2014): Edition 2 (June 2014)

Volume 10 (2014): Edition 1 (March 2014)

Volume 9 (2013): Edition 4 (December 2013)

Volume 9 (2013): Edition 3 (September 2013)

Volume 9 (2013): Edition 2 (June 2013)

Volume 9 (2013): Edition 1 (March 2013)

Détails du magazine
Format
Magazine
eISSN
2784-1391
Première publication
12 Apr 2013
Période de publication
4 fois par an
Langues
Anglais

Chercher

Volume 15 (2019): Edition 3 (September 2019)

Détails du magazine
Format
Magazine
eISSN
2784-1391
Première publication
12 Apr 2013
Période de publication
4 fois par an
Langues
Anglais

Chercher

2 Articles
access type Accès libre

The Potential Wind Power Resource in Central-South of the Constanta County

Publié en ligne: 17 Feb 2020
Pages: 1 - 12

Résumé

Abstract

Usually, wind turbine generator’s structures or radio masts are located in wind exposed sites. The paper aims to investigate the wind conditions in the nearby area of Cobadin Commune, Constanta County, Romania at heights of 150-200m above the surface using global reanalysis data sets CFSR, ERA 5, ERA I and MERRA 2.

Using the extreme value theory and the physical models of the datasets, the research focuses on the assessment of the maximum values that are expected for the wind speeds, but the wind statistics created can be used for a further wind or energy yield calculation.

Without reaching the survival wind speed for wind turbine generators, with mean wind speed values higher than 7 m/s and considering the cut-in and cut-out wind speeds of 3 m/s, respectively 25 m/s, the site can be exploited in more than 90% of the time to generate electricity, thus, the paper is addressed to the investors in the energy of renewable sources. At the same time, the insights of the wind characteristics and the knowledge of the extreme values of the wind speed can be useful, not just for the designers, in the rational assessment of the structural safety of wind turbines, but also those evaluating the insured losses.

Mots clés

  • wind energy
  • extreme values
  • wind Constanta County
  • wind turbine generators
access type Accès libre

Wind Load Design of Photovoltaic Power Plants by Comparison of Design Codes and Wind Tunnel Tests

Publié en ligne: 17 Feb 2020
Pages: 13 - 27

Résumé

Abstract

Wind load design of the ground-mounted photovoltaic (PV) power plants requires interpretation of the design code considering the particularities of these structures. The PV power plants consist on systems of several solar panels. Wind load pressure coefficient evaluation, by design code, for a single solar panel considered as a canopy roof, neglect the group effect and the air permeability of the system. On the other hand, the canopy roofs are structures with medium serviceability, but the PV power plants are structures with low serviceability. This paper discuss the difficulties of the wind load design for the PV power plants ground mounted in Romania and compares the Romanian, German, European and American wind design code specifications with the parameters provided by the wind tunnel test, for this type of structures. For Romanian wind load design an evolution of the 1990, 2004 and 2012 editions of the design codes specifications is also studied. Evaluation of the internal resultants for the structural elements of the PV panel, considering the pressure coefficients and the force coefficients, conducts to different results. Further code explanations and design specifications are required for wind design of the PV power plants.

Mots clés

  • wind pressure coefficient
  • wind force coefficient
  • photovoltaic panel
  • group effect
2 Articles
access type Accès libre

The Potential Wind Power Resource in Central-South of the Constanta County

Publié en ligne: 17 Feb 2020
Pages: 1 - 12

Résumé

Abstract

Usually, wind turbine generator’s structures or radio masts are located in wind exposed sites. The paper aims to investigate the wind conditions in the nearby area of Cobadin Commune, Constanta County, Romania at heights of 150-200m above the surface using global reanalysis data sets CFSR, ERA 5, ERA I and MERRA 2.

Using the extreme value theory and the physical models of the datasets, the research focuses on the assessment of the maximum values that are expected for the wind speeds, but the wind statistics created can be used for a further wind or energy yield calculation.

Without reaching the survival wind speed for wind turbine generators, with mean wind speed values higher than 7 m/s and considering the cut-in and cut-out wind speeds of 3 m/s, respectively 25 m/s, the site can be exploited in more than 90% of the time to generate electricity, thus, the paper is addressed to the investors in the energy of renewable sources. At the same time, the insights of the wind characteristics and the knowledge of the extreme values of the wind speed can be useful, not just for the designers, in the rational assessment of the structural safety of wind turbines, but also those evaluating the insured losses.

Mots clés

  • wind energy
  • extreme values
  • wind Constanta County
  • wind turbine generators
access type Accès libre

Wind Load Design of Photovoltaic Power Plants by Comparison of Design Codes and Wind Tunnel Tests

Publié en ligne: 17 Feb 2020
Pages: 13 - 27

Résumé

Abstract

Wind load design of the ground-mounted photovoltaic (PV) power plants requires interpretation of the design code considering the particularities of these structures. The PV power plants consist on systems of several solar panels. Wind load pressure coefficient evaluation, by design code, for a single solar panel considered as a canopy roof, neglect the group effect and the air permeability of the system. On the other hand, the canopy roofs are structures with medium serviceability, but the PV power plants are structures with low serviceability. This paper discuss the difficulties of the wind load design for the PV power plants ground mounted in Romania and compares the Romanian, German, European and American wind design code specifications with the parameters provided by the wind tunnel test, for this type of structures. For Romanian wind load design an evolution of the 1990, 2004 and 2012 editions of the design codes specifications is also studied. Evaluation of the internal resultants for the structural elements of the PV panel, considering the pressure coefficients and the force coefficients, conducts to different results. Further code explanations and design specifications are required for wind design of the PV power plants.