Accès libre

Corrosion of Transparent Electrodes Study

À propos de cet article

Citez

This work reports a study of corrosion lifetime of transparent electrodes deposited on the microscopic glass substrate. A procedure was developed for obtaining the transparent electrode by spray method. The corrosion lifetime variation in the presence of 1.5 M NaOH medium chemically degraded at room temperature before and after gamma irradiation was determined by measuring the evolution of the structure, electrical and optical characteristics. The mean values of transmittance up to 25 month before and after irradiation were calculated 91% ±6% and 96±7%, respectively. The average value of resistivity after corrosion and age time after γ-irradiation was 0.016±9% Ω.cm and 0.017± 4% at 1.0 kHz. No significant changes observed for 27 hr corrosion and 25 month age time of the transparent electrodes in NaOH solution.

eISSN:
2083-4799
Langue:
Anglais
Périodicité:
4 fois par an
Sujets de la revue:
Materials Sciences, Functional and Smart Materials