Efficacy of in-house clear aligner therapy mechanics on root torque: an in-vitro study
20 mar 2024
Acerca de este artículo
Publicado en línea: 20 mar 2024
Páginas: 13 - 24
Recibido: 01 dic 2023
Aceptado: 01 ene 2024
DOI: https://doi.org/10.2478/aoj-2024-0003
Palabras clave
© 2024 Rüveyda Doğrugören et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.


Descriptive statistics and post hoc comparisons of torque values (degree) of the lateral incisor teeth
1° | 2° | 3° | 4° | 5° | ||
---|---|---|---|---|---|---|
Group | Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | |
Control | 1.14 ± 0.85 | 1.66 ± 0.82 | 1.42 ± 0.74 | 1.32 ± 0.62 | 1.49 ± 0.42ab | 0.852 |
Buccal Power Ridge | 1.40 ± 1.12 | 1.34 ± 1.02 | 1.32 ± 1.07 | 0.98 ± 0.53 | 1.07 ± 0.56a | 0.963 |
Buccal and Palatal |
0.83 ± 0.40A | 1.16 ± 0.71AB | 1.49 ± 0.81AB | 2.04 ± 0.85AB | 2.15 ± 0.40Bb | 0.004 |
Vertical Ellipsoid | 1.22 ± 0.74 | 1.43 ± 0.76 | 1.33 ± 1.18 | 1.31 ± 0.80 | 1.59 ± 0.64ab | 0.644 |
Horizontal Ellipsoid | 0.79 ± 0.70 | 1.25 ± 0.71 | 1.88 ± 1.12 | 1.56 ± 1.15 | 2.08 ± 0.96ab | 0.072 |
0.591 | 0.732 | 0.626 | 0.145 | 0.017 |
Descriptive statistics and post hoc comparisons of effected torque values of the canine teeth
1° | 2° | 3° | 4° | 5° | ||
---|---|---|---|---|---|---|
Group | Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | |
No Attachment | 1.23 ± 0.69 | 2.12 ± 0.95abc | 1.64 ± 1.37 | 0.99 ± 0.60 | 1.78 ± 1.25 | 0.209 |
Buccal Power Ridge | 1.20 ± 0.50A | 3.69 ± 1.43Ba | 2.88 ± 1.56AB | 1.86 ± 1.26AB | 3.10 ± 3.05AB | 0.015 |
Buccal and Palatal |
1.78 ± 0.92 | 0.94 ± 0.57b | 1.04 ± 0.62 | 1.76 ± 1.90 | 1.21 ± 1.15 | 0.506 |
Vertical Ellipsoid | 0.90 ± 0.62 | 1.83 ± 1.34abc | 0.85 ± 0.76 | 1.86 ± 1.78 | 1.33 ± 1.31 | 0.278 |
Horizontal Ellipsoid | 1.52 ± 1.00 | 1.24 ± 0.63c | 1.57 ± 0.89 | 1.10 ± 0.77 | 1.51 ± 1.30 | 0.870 |
0.297 | <0.001 |
0.034 | 0.698 | 0.324 |
Descriptive statistics and post hoc comparisons of effected torque values of the central incisor teeth
1° | 2° | 3° | 4° | 5° | ||
---|---|---|---|---|---|---|
Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | Mean ± SD | ||
No Attachment | 2.00 ± 1.11 | 1.36 ± 0.92 | 1.24 ± 0.95 | 1.23 ± 0.80 | 1.24 ± 1.08 | 0.630 |
Buccal Power Ridge | 1.14 ± 0.67 | 1.27 ± 1.31 | 0.94 ± 0.67 | 1.80 ± 1.11 | 1.24 ± 0.73 | 0.486 |
Buccal and Palatal |
0.91 ± 0.86 | 1.20 ± 0.88 | 1.15 ± 0.62 | 0.94 ± 0.48 | 0.99 ± 0.51 | 0.868 |
Vertical Ellipsoid | 1.21 ± 0.89 | 1.18 ± 1.13 | 1.16 ± 0.95 | 1.37 ± 0.74 | 1.12 ± 0.65 | 0.916 |
Horizontal Ellipsoid | 1.05 ± 0.65 | 0.89 ± 0.49 | 0.84 ± 0.77 | 0.93 ± 0.87 | 0.87 ± 0.45 | 0.903 |
0.175 | 0.870 | 0.885 | 0.278 | 0.896 |