MRI reduces variation of contouring for boost clinical target volume in breast cancer patients without surgical clips in the tumour bed
, , , , , , , , and
Mar 17, 2017
About this article
Article Category: Research Articles
Published Online: Mar 17, 2017
Page range: 160 - 168
Received: Dec 05, 2016
Accepted: Feb 19, 2017
DOI: https://doi.org/10.1515/raon-2017-0014
Keywords
© 2017 Noora Al-Hammadi, Palmira Caparrotti, Saju Divakar, Mohamed Riyas, Suparna Halsnad Chandramouli, Rabih Hammoud, Jillian Hayes, Maeve Mc Garry, Satheesh Prasad Paloor, Primoz Petric
This article is distributed under the terms of the Creative Commons Attribution Non-Commercial License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.


Accuracy index (AI) and inter-delineation distances (IDD), based on the expert consensus (EC) delineation as the reference_ The differences in AI and IDD between CT and MRI were statistically significant (p < 0_05)
CT | MRI | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Case | ||||||||||||
IDD [mm] | AI | IDD [mm] | AI | |||||||||
2.1 | 0.8 | 38 | 0.88 | 0.02 | 3 | 1.8 | 0.58 | 32 | 0.88 | 0.01 | 2 | |
3.6 | 1.9 | 53 | 0.78 | 0.1 | 12 | 3.2 | 1.9 | 59 | 0.83 | 0.02 | 3 | |
3.9 | 2.6 | 67 | 0.67 | 0.07 | 10 | 3.2 | 1.8 | 56 | 0.78 | 0.02 | 2 | |
2.3 | 1 | 43 | 0.75 | 0.06 | 8 | 2.3 | 0.9 | 39 | 0.77 | 0.05 | 6 | |
6 | 4 | 67 | 0.61 | 0.15 | 24 | 4.5 | 2.1 | 47 | 0.73 | 0.14 | 20 | |
2.6 | 1.1 | 42 | 0.82 | 0.02 | 2 | 2.6 | 1 | 38 | 0.83 | 0.02 | 2 | |
6 | 4.1 | 68 | 0.64 | 0.09 | 14 | 3.6 | 1.8 | 50 | 0.76 | 0.05 | 7 | |
2.4 | 1.2 | 50 | 0.85 | 0.02 | 2 | 2.2 | 1 | 45 | 0.86 | 0.04 | 4 | |
3 | 2.9 | 97 | 0.81 | 0.04 | 5 | 2.9 | 1.8 | 62 | 0.80 | 0.05 | 6 | |
4.5 | 3.5 | 78 | 0.77 | 0.07 | 9 | 3.3 | 2 | 61 | 0.84 | 0.02 | 2 | |
3.3 | 2 | 61 | 0.74 | 0.09 | 12 | 2.5 | 1.3 | 52 | 0.83 | 0.02 | 3 | |
3.4 | 2.3 | 68 | 0.77 | 0.06 | 8 | 3.6 | 1.7 | 47 | 0.80 | 0.02 | 2 | |
3.6 | 2.3 | 61 | 0.76 | 0.07 | 9 | 3 | 1.5 | 49 | 0.81 | 0.04 | 5 |
Results for inter-observer variation in contouring_ The difference in mean generalized conformity index (CIgen) between the CT and MRI based contouring was statistically significant (p = 0_007)
Case | CT | MRI | ||||
---|---|---|---|---|---|---|
198 (10) | 5 | 0.85 | 106 (4) | 4 | 0.87 | |
241 (37.5) | 16 | 0.69 | 256 (28) | 11 | 0.77 | |
108 (20.7) | 19 | 0.56 | 125 (10) | 8 | 0.75 | |
75 (18.1) | 24 | 0.64 | 92 (12) | 13 | 0.69 | |
175 (47.9) | 27 | 0.46 | 217 (68) | 31 | 0.63 | |
140 (10.1) | 7 | 0.76 | 125 (14) | 11 | 0.76 | |
103(39.7) | 39 | 0.48 | 64 (2) | 4 | 0.66 | |
180 (22.5) | 12 | 0.79 | 158 (14) | 9 | 0.8 | |
135 (19.8) | 15 | 0.77 | 126 (20) | 16 | 0.71 | |
204 (44.3) | 22 | 0.68 | 215 (19) | 9 | 0.76 | |
99 (14.4) | 15 | 0.66 | 135 (11) | 8 | 0.79 | |
195 (27.3) | 14 | 0.69 | 210 (29) | 14 | 0.74 | |
154 (26) | 18 | 0.67 (0.12) | 152 (19) | 12 | 0.74 (0.07) |