[1. Van Dyk J, Barnett RB, Cygler JE, Shragge PC. Commissioning and quality assurance of treatment planning computer. Int J Radiat Oncol Biol Phys. 1993; 26:172-3.]Search in Google Scholar
[2. Fraass B, Doppke K, Hunt M, Kutcher G, Starkschall G, Stern R, et al. American Association of Physicists in Medicine Radiation Therapy Committee Task Group 53: quality assurance for clinical radiotherapy treatment planning. Med Phys. 1998; 25:1773-829.10.1118/1.598373]Open DOISearch in Google Scholar
[3. International Atomic Energy Agency. Technical reports series no.430: Commissioning and quality assuracne of computerized planning system for radiation treatment of cancer. Vienna, 2004.]Search in Google Scholar
[4. Tsai JS, Wazer DE, Ling MN, Wu JK, Fagundes M, DiPetrillo T, et al. Dosimetric verification of the dynamic intensity modulayed radiation therapy of 92 patients. Int J Radiat Oncol biol Phys. 1998 ; 40:1213-30.10.1016/S0360-3016(98)00009-1]Open DOISearch in Google Scholar
[5. American Association of Physicists in Medicine (AAPM). Tissue inhomogeneity corrections for megavoltage photon beams: 2004. AAPM Report No. 85.]Search in Google Scholar
[6. International Atomic Energy Agency. Absorbed dose determination in photon and electron beams. International Atomic Energy Agency (IAEA) Technical Report Series 398. 2004:148-54.]Search in Google Scholar
[7. Kung J H, Chen F. H, Kuchnir F. K. A monitor unit verification in intensity modulated radiotherapy as a dosimetry quality assurance. Med Phys. 2000; 27: 2226-30.10.1118/1.128655311099189]Open DOISearch in Google Scholar
[8. Xing L, Chen Y, Luxton G, Li J G, Boyer ALl. Monitor unit calculation for intensity modulated photon field by a simple scatter-summation algorithm. Phys Med Biol. 2000; 45:173-6.10.1088/0031-9155/45/3/40110730973]Open DOISearch in Google Scholar
[9. Zhu J, Yin F, Kim J H. Point dose verification for intensity modulated radiosurgery using Clarkson’s method. Med Phys. 2003; 30:2218-21.10.1118/1.158949512945987]Open DOISearch in Google Scholar
[10. Stathakis S, Kappas C, Theodorou K, Papanikolaou N, Rosenwald JC. An inhomogeneity correction algorithm for irregular fields of high-energy photon beams based on Clarkson integration and the 3D beam substraction method. Am Coll Med Phys. 2006; 7:1-13.10.1120/jacmp.v7i1.2042572247716518312]Search in Google Scholar
[11. Haslam JJ, Bonta DV, Lujan AE, Rash C, Jackson W, Roeske JC. Comparison of dose calculated by an intensity modulated radiotherapy treatment planning system and an independent monitor unit verification program. Am Coll Med Phys. 2003; 4:224-30.10.1120/jacmp.v4i3.2519572444612841793]Search in Google Scholar
[12. Georg D, Stock M, Kroupa B, Olofsson J, Nyholm T, Ahesjo A, Karlsson M. Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience. Phys Med Biol. 2007; 52: 4981-92.10.1088/0031-9155/52/16/01817671348]Open DOISearch in Google Scholar