Otwarty dostęp

Measurement of absorbed dose in water in brachytherapy

, ,  oraz   
23 gru 2024

Zacytuj
Pobierz okładkę

IAEA, 2002. Calibration of Photon and Beta Ray Sources Used in Brachytherapy. Number 1274 in TECDOC Series. International Atomic Energy Agency; 2002.Search in Google Scholar

Nath R, Anderson LL, Luxton G, Weaver KA, Williamson JF, Meigooni AS. Dosimetry of interstitial brachytherapy sources: Recommendations of the AAPM Radiation Therapy Committee Task Group No. 43. Med Phys. 1995;22(2):209-234. https://doi.org/10.1118/1.597458Search in Google Scholar

Williamson JF. Comparison of measured and calculated dose rates in water near I-125 and Ir-192 seeds. Medical Physics. 1991;18(4):776-786. https://doi.org/10.1118/1.596631Search in Google Scholar

DeWerd LA, Ibbott GS, Meigooni AS, et al. A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO. Medical Physics. 2011;38(2):782-801. https://doi.org/10.1118/1.3533720Search in Google Scholar

Daskalov GM, Löffler E, Williamson JF. Monte Carlo-aided dosimetry of a new high dose-rate brachytherapy source. Medical Physics. 1998;25(11):2200-2208. https://doi.org/10.1118/1.598418Search in Google Scholar

Boutillon M, Perroche AM. Ionometric determination of absorbed dose to water for cobalt-60 gamma rays. Phys Med Biol. 1993;38(3):439-454. https://doi.org/10.1088/0031-9155/38/3/010Search in Google Scholar

ICRU Report 90, Key Data For Ionizing-Radiation Dosimetry: Measurement Standards And Applications – ICRU. Accessed April 17, 2024. https://www.icru.org/report/icru-report-90-key-data-for-ionizing-radiation-dosimetry-measurement-standards-and-applications.Search in Google Scholar

Szymko M. Budowa wzorca dawki pochłoniętej w wodzie dla źródeł stosowanych w brachyterapii [Construction of the water absorbed dose standard for sources used in brachytherapy]. [PhD thesis]. Warsaw University of Technology; 2024. https://repo.pw.edu.pl/info/phd/WUT8634915e3b994ce4a077bf2aedf3373e/Search in Google Scholar

IAEA. Absorbed Dose Determination in External Beam Radiotherapy. Technical Reports Series. Published online 2024. https://doi.org/10.61092/iaea.ve7q-y94kSearch in Google Scholar

Szymko MM, Knyziak AB, Derlaciński M. Graphite ionization chamber as an ionometric standard of absorbed dose to water for Co-60 gamma radiation. Measurement. 2022;194:110928. https://doi.org/10.1016/j.measurement.2022.110928Search in Google Scholar

Andreo P, Burns DT, Nahum AE, Seuntjens J, Attix,FH. Fundamentals of ionizing radiation dosimetry. John Wiley & Sons; 2017.Search in Google Scholar

Szymko MM, Michalik L, Knyziak AB, Wójtowicz AW. Development and characterization of air kerma cavity standard. Measurement. 2019;136:647-657. https://doi.org/10.1016/j.measurement.2019.01.010Search in Google Scholar

Bravos manual. https://www.varian.com/resources-support/support/product-documentationSearch in Google Scholar

Rozporządzenie Ministra Zdrowia z dnia 12 grudnia 2022 r. w sprawie testów eksploatacyjnych urządzeń radiologicznych i urządzeń pomocniczych [Regulation of the Minister of Health of 12 December 2022 on operational tests of radiological devices and auxiliary devices]. Dz.U. 2022 poz. 2759Search in Google Scholar

Sander T. Air kerma and absorbed dose standards for reference dosimetry in brachytherapy. BJR. 2014;87(1041):20140176. https://doi.org/10.1259/bjr.20140176Search in Google Scholar

Język:
Angielski
Częstotliwość wydawania:
4 razy w roku
Dziedziny czasopisma:
Medycyna, Inżynieria biomedyczna, Fizyka, Fizyka techniczna i stosowana, Fizyka medyczna