Klein EE, Hanley J, Bayouth J, et al. Task Group 142 report: Quality assurance of medical accelerators. Med Phys. 2009;36(9Part1):4197-4212. https://doi.org/10.1118/1.3190392 Search in Google Scholar

Tsai J-S, Curran BH, Sternick ES, Engler MJ. The measurement of linear accelerator isocenter motion using a three-micrometer device and an adjustable pointer. Int J Radiat Oncol. 1996;34(1):189-195. https://doi.org/10.1016/0360-3016(95)02085-3 Search in Google Scholar

Hanley J, Dresser S, Simon W, et al. AAPM Task Group 198 Report: An implementation guide for TG 142 quality assurance of medical accelerators. 2021;48(10):e830-e885. https://doi.org/10.1002/mp.14992 Search in Google Scholar

Doudard A, Guérin C, Dufreneix S, Josset S. Design and automation of specific geometric quality controls for cone-radiosurgery treatments. Phys Med. 2022;96:1-8. https://doi.org/10.1016/j.ejmp.2022.02.011 Search in Google Scholar

Bodjanski M, inventor; Carl Zeiss IQS Software R&D Center Sp zoo, assignee. Optical tracking method and system based on passive markers. U.S. Patent No. US 2017 / 0258531 A1. September 14, 2017. Search in Google Scholar

Zhang M, Zhou S, Qu T. What Do We Mean When We Talk about the Linac Isocenter? International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. 2015;4(3):233-242. https://doi.org/10.4236/ijmpcero.2015.43028 Search in Google Scholar

Calibration Certificate Z3-Z33.4180.167.2023.1888.4, Central Office of Measures (COM, Poland) Search in Google Scholar

Lutz W, Winston KR, Maleki N. A system for stereotactic radiosurgery with a linear accelerator. Int J Radiat Oncol Biol Phys. 1988;14(2):373-381. https://doi.org/10.1016/0360-3016(88)90446-4 Search in Google Scholar

Skworcow P, Mills JA, Haas OC, Burnham KJ. A new approach to quantify the mechanical and radiation isocentres of radiotherapy treatment machine gantries. Phys Med Biol. 2007;52(23):7109-7124. https://doi.org/10.1088/0031-9155/52/23/022 Search in Google Scholar

Heikkilä J, Seppälä J, Nuutinen, Vanne A, Lahtinen T. A photographic technique for quick assessment of mechanical isocenter of a linear accelerator. Technical Innovations & Patient Support in Radiation Oncology. 2017;2(1-4). https://doi.org/10.1016/j.tipsro.2017.03.001 Search in Google Scholar

Chojnowski JM, Sykes JR, Thwaites DI. A novel method to determine linac mechanical isocenter position and size and example of specific QA application. J Appl Clin Med Phys. 2021;22(7):44-55. https://doi.org/10.1002/acm2.13257 Search in Google Scholar