This work is licensed under the Creative Commons Attribution 4.0 International License.
Ferlay J, Colombet M, Soerjomataram I, Parkin DM, Pineros M, Znaor A, Bray F. Cancer statistics for the year 2020. An overview. Int J Cancer, 2021, 136(5):E359-E386, 10.1002/ijc.29210FerlayJColombetMSoerjomataramIParkinDMPinerosMZnaorABrayFCancer statistics for the year 2020An overview. Int J Cancer20211365E359E38610.1002/ijc.29210Open DOISearch in Google Scholar
Brown BH, Tidy JA, Boston K, Blackett AD, Smallwood RH, Sharp F. The relationship between tissue structure and imposed electrical current flow in cervical neoplasia. Lancet, 2000, 355, 892-895, 10.1016/S0140-6736(99)09095-9BrownBHTidyJABostonKBlackettADSmallwoodRHSharpFThe relationship between tissue structure and imposed electrical current flow in cervical neoplasiaLancet200035589289510.1016/S0140-6736(99)09095-9Open DOISearch in Google Scholar
Brown BH, Milnes P, Abdul S, Tidy JA. Detection of cervical intraepithelial neoplasia using impedance spectroscopy - prospective study. BJOG, 2005, 112.802-806, 10.1111/j.1471-0528.2004.00530.xBrownBHMilnesPAbdulSTidyJADetection of cervical intraepithelial neoplasia using impedance spectroscopy - prospective studyBJOG2005112802–80610.1111/j.1471-0528.2004.00530.x15924541Open DOISearch in Google Scholar
Abdul S, Brown BH, Milnes P, Tidy JA. The Use of electrical impedance spectroscopy in the detection of cervical intraepithelial neoplasia. Int.J. Gynecol Cancer, 2006, 16. 1823-1832, 10.1111/j.1525-1438.2006.00651.xAbdulSBrownBHMilnesPTidyJAThe Use of electrical impedance spectroscopy in the detection of cervical intraepithelial neoplasiaInt.J. Gynecol Cancer2006161823–183210.1111/j.1525-1438.2006.00651.x17009978Open DOISearch in Google Scholar
Tidy JA, Brown BH, Healey TJ, Daayana S, Martin M, Prendiville W, Kitchener HC. Accuracy of detection of high-grade cervical intraepithelial neoplasia using electrical impedance spectroscopy with colposcopy. BJOG, 2013, 120.400-410, 10.1111/1471-0528.12096TidyJABrownBHHealeyTJDaayanaSMartinMPrendivilleWKitchenerHCAccuracy of detection of high-grade cervical intraepithelial neoplasia using electrical impedance spectroscopy with colposcopyBJOG2013120400–41010.1111/1471-0528.12096359799323289897Open DOISearch in Google Scholar
Tidy JA, Brown BH, Lyon RE, Healey TJ, Palmer JE. Are colposcopy and electrical impedance spectroscopy complementary when used to detect high-grade cervical neoplasia? European Journal of Gynaecological Oncology, 2018, 39.70-75.TidyJABrownBHLyonREHealeyTJPalmerJEAre colposcopy and electrical impedance spectroscopy complementary when used to detect high-grade cervical neoplasia?European Journal of Gynaecological Oncology20183970–75Search in Google Scholar
Cole KS, Cole RH. Dispersion and absorption in dielectrics. J. Chem. Phys, 1941, 9341-9351, 10.1063/1.1750906ColeKSColeRHDispersion and absorption in dielectricsJ. Chem. Phys19419341935110.1063/1.1750906Open DOISearch in Google Scholar
Coleman TF, Li Y. An Interior Trust Region Approach for Nonlinear Minimization Subject to Bounds. SIAM J. Optimization, 1996, 6(2):418-445, 10.1137/0806023ColemanTFLiYAn Interior Trust Region Approach for Nonlinear Minimization Subject to BoundsSIAM J. Optimization19966241844510.1137/0806023Open DOISearch in Google Scholar
Moqadam SM, Grewal PK, Haeri Z, Ingledew PA, Kohli K, Golnaraghi F. Cancer detection based on electrical impedance spectroscopy: A clinical study. Journal of Electrical Bioimpedance, 2018, 9.17-23, 10.2478/joeb-2018-0004MoqadamSMGrewalPKHaeriZIngledewPAKohliKGolnaraghiFCancer detection based on electrical impedance spectroscopy: A clinical studyJournal of Electrical Bioimpedance2018917–2310.2478/joeb-2018-0004785202033584916Open DOISearch in Google Scholar
Brown BH, Highfield PE, Tidy JA. Prognostic value of Electrical Impedance Spectroscopy (EIS) when used as an adjunct to Colposcopy - a longitudinal study. Journal of Electrical Bioimpedance, 2020, 11.81-86, 10.2478/joeb-2020-0012BrownBHHighfieldPETidyJAPrognostic value of Electrical Impedance Spectroscopy (EIS) when used as an adjunct to Colposcopy - a longitudinal studyJournal of Electrical Bioimpedance20201181–8610.2478/joeb-2020-0012785198333584907Open DOISearch in Google Scholar
James G, Witten D, Hastie T, Tibshirani R. An Introduction to Statistical Learning. Springer Science, New York, USA; 2017.JamesGWittenDHastieTTibshiraniRAn Introduction to Statistical LearningSpringer Science, New York, USA;2017Search in Google Scholar
Kuhn M, Johnson K. Applied Predictive Modeling. Springer Science, New York, USA; 2013, 10.1007/978-1-4614-6849-3KuhnMJohnsonKApplied Predictive ModelingSpringer Science, New York, USA;201310.1007/978-1-4614-6849-3Open DOISearch in Google Scholar
Li P, Highfield PE, Lang ZQ, Kell D. A data-driven modelling based approach to evaluating prognostic value of Electrical Impedance Spectroscopy for cervical cancer diagnosis. 11th IFAC Symposium on Biological and Medical Systems, 19-22 September, 2021, Ghent, Belgium.LiPHighfieldPELangZQKellDA data-driven modelling based approach to evaluating prognostic value of Electrical Impedance Spectroscopy for cervical cancer diagnosis11th IFAC Symposium on Biological and Medical Systems, 19-22 September2021Ghent, Belgium10.1016/j.ifacol.2021.10.256Search in Google Scholar
Rencher AC. Methods of Multivariate Analysis, 2nd Edition. John Wiley & Sons, Inc., New York, USA; 2002, 10.1002/0471271357RencherACMethods of Multivariate Analysis, 2nd EditionJohn Wiley & Sons, Inc., New York, USA;200210.1002/0471271357Open DOISearch in Google Scholar
Christodoulou E, Ma J, Gollins GS, Steyerberg EW, Verbakel JY, Calster BV. A systematic review shows no performance benefit of machine learning over logistic regression for clinical prediction models. Journal of Clinical Epidemiology, 2019, 110. 12-22, 10.1016/j.jclinepi.2019.02.004ChristodoulouEMaJGollinsGSSteyerbergEWVerbakelJYCalsterBVA systematic review shows no performance benefit of machine learning over logistic regression for clinical prediction modelsJournal of Clinical Epidemiology201911012–2210.1016/j.jclinepi.2019.02.00430763612Open DOISearch in Google Scholar
Fawcett T. An introduction to ROC analysis. Pattern Recognition Letters, 2006, 27.861-874, 10.1016/j.patrec.2005.10.010FawcettTAn introduction to ROC analysisPattern Recognition Letters200627861–87410.1016/j.patrec.2005.10.010Open DOISearch in Google Scholar
Schisterman EF, Perkins NJ, Liu A, Bondell H. Optimal cut-point and its corresponding Youden index to discriminate individuals using pooled blood samples. Epidemiology, 2005, 16.73-81, 10.1097/01.ede.0000147512.81966.baSchistermanEFPerkinsNJLiuABondellHOptimal cut-point and its corresponding Youden index to discriminate individuals using pooled blood samplesEpidemiology20051673–8110.1097/01.ede.0000147512.81966.ba15613948Open DOISearch in Google Scholar
Murdoch C, Brown BH, Hearnden V, Speight PM, D'Apice K, Hegarty AM, Tidy JA, Healey TJ, Highfield PE, Thornhill MH. Use of electrical impedance spectroscopy to detect malignant and potentially malignant oral lesions. International Journal of Nanomedicine, 2014, 9.4521-4532, 10.2147/IJN.S64087MurdochCBrownBHHearndenVSpeightPMD'ApiceKHegartyAMTidyJAHealeyTJHighfieldPEThornhillMHUse of electrical impedance spectroscopy to detect malignant and potentially malignant oral lesionsInternational Journal of Nanomedicine201494521–453210.2147/IJN.S64087418175125285005Open DOISearch in Google Scholar