Influence of temperature on detectable minimum rotation rate in i-FOGs using Er-doped SFSs
, oraz
14 maj 2022
O artykule
Data publikacji: 14 maj 2022
Zakres stron: 146 - 151
Otrzymano: 01 lut 2022
DOI: https://doi.org/10.2478/jee-2022-0019
Słowa kluczowe
© 2022 Emirhan Saǧ et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
In this study, an interferometric fiber optic gyroscope (I-FOG) model exploiting the double-pass backward (DPB) erbium-doped superfluorescent fiber source (SFS) with both thin-film filter (TFF) and fiber bragg grating (FBG) reflectors has been constructed and the effects of temperature variations on mean wavelength and detectable minimum rotation rate (DMRR) have been theoretically analyzed. the simulations corresponding with the relations between these parameters for temperature variations in the range of −60 °C to + 90 °C, have been performed using Matlab 2021b. DMRR variations have been found as 6.01 ppm/K and 3.83 ppm/K for the system with TFF, whilst they are 15.31 ppm/K and 1.58 ppm/K for the system with FBG.