Micelle-based restricted access ion-pair microextraction of phosphate at trace levels in water samples for separation, preconcentration and determination
Kategoria artykułu: Research Article
Data publikacji: 30 kwi 2020
Zakres stron: 89 - 96
DOI: https://doi.org/10.2478/ebtj-2020-0010
Słowa kluczowe
© 2020 Mustafa Soylak, Haldun Hilmi Gorucu and Erkan Yilmaz, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.
A new and simple micelles-rich restricted access supramolecular solvent-based liquid phase microextraction method (RASUPRASs-LPME) based on the ion-pair complex formation of phosphate (PO43-) ions with ammonium heptamolybdate and malachite green in acidic medium was developed. The phosphate ion concentration after microextraction of the ion-pair complex to the hexagonal aggregates of decanoic acid (DA) was measured with micro-volume UV-Vis spectrophotometer at 625 nm. All analytical parameters which are effective on the method such as acid type and concentration, supramolecular solvent volume, amount of the components forming the complex, sample volume, were optimized. The preconcentration factor (PF), limit of detection (LOD) and limit of quantification (LOQ) for the developed method was found to be 15, 9.6 and 32.1, respectively. The RA-SUPRAs-LPME method was finally applied for the analysis of the phosphate content of different types of water samples.