Analogous Mode Implementation of State Space Based Control of Buck Converter
oraz
01 lut 2023
O artykule
Data publikacji: 01 lut 2023
Zakres stron: 91 - 104
Otrzymano: 13 sie 2022
Przyjęty: 13 gru 2022
DOI: https://doi.org/10.2478/bipie-2022-0006
Słowa kluczowe
© 2022 Diana-Elena Cucoș et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The new requirements for point-of-load converters include the dynamic behavior, leading to the need for improvements in the control system for the conventional buck converter. Usually, the regulator design, in order to secure stability at parameter or mode variation, aims a zero steady-state error and a phase margin over 60 degrees. The design based on Venable’s K-factor method (Venable, 1983) helps achieve this topic. A more modern control design method based on State Space is used progressively on digital platforms. This paper extends the merits of the State Space based design procedure with an analogous mode implementation.