To investigate the relationship between pre-treatment, predicted post-treatment, and clinically achieved numbers and locations of occlusal contact in cases treated using the Invisalign® Lite appliance (Align Technology, San Jose, California, USA).
Following the application of exclusion and inclusion criteria, 34 patients treated with the Invisalign® Lite appliance were selected. Occlusal contacts were measured at the initial, predicted, and achieved stages on amiga disc file (.adf file) files using the imaging software ImageJ (National Institutes of Health, Bethesda, MD, USA). Descriptive statistics were calculated. Predicted values were provided by Align Technology’s treatment planning software interface, ClinCheck®.
Most patients were female (
For minor tooth movement treatment with Invisalign® Lite, more than 50% loss of posterior contact was observed in the achieved outcome when compared to either the initial or predicted number of occlusal contacts.