After more than 10 years of research conducted at the West Pomeranian University of Technology in Szczecin, it is possible to extensively describe many important aspects of pile-soil interaction. In this paper authors would like to show a practical case of determining a static load test curve in case of changed length or diameter of a pile without the necessity of repeating static load tests. In their analysis, authors used the results of a static load test conducted in a full range of loads by Energopol Szczecin S.A. [1] for CFA piles bored in mostly loam soil conditions. By analysing those results it was possible to determine the previously described relation [1] between pile maximum bearing capacity as a function of pile length, diameter, and CPTU probe cone resistance at the level of pile base. Furthermore, it allows to obtain analytical relations between parameters describing static load test curve and its diameter and length that can be used for practical curve conversion. The parameters of the pile used in the analysis can be seen in Tab.1.
Parameters of analyzed piles
|
||||||
---|---|---|---|---|---|---|
27.5 | 1 | 27.5 | 6590 | 0.61 | 0.00062 | |
27.5 | 2 | 13.75 | 8700 | 1.4 | 0.00077 | |
31.5 | 1.5 | 21 | 12500 | 0.65 | 0.00087 | |
33.5 | 1.5 | 22.33 | 11850 | 0.1 | 0.00064 | |
33.5 | 1.5 | 22.33 | 12200 | 0.5 | 0.00037 |
During the process of structural design, it is vital to correctly establish maximum bearing capacity of a pile, which is the most important factor determining safety. Bearing capacity of a pile can be obtained through several methods, as described by Briaud [2], Hansen [3], Chin [4], Coyle and Reese [5], Dung and Kim [6], Gwizdała [7], Meyer and Kowalow [8]. It is also worth noting that the method described by Chin is a special case of the Meyer-Kowalow method for a case when skin resistance is equal to the base resistance of the pile. In the further part of this paper, authors used a method that allows for a full description of the continuous load-settlement curve, which has been proposed by Meyer and Kowalow (M-K method) in 2010 [8]. M-K curves satisfy physical conditions from Boussinesq's theory, as described by equation (1) for values of load closer to maximum bearing capacity tend to asymptote described by formula (2).
It is possible to write a equation describing a continuous load-settlement curve (M-K curve) in a full range of loads, that is proposed in the M-K method [8]:
pile settlement [mm], inverse aggregated Winkler modulus [mm/kN], maximum bearing capacity of a pile [kN], parameter that indicates proportion between skin and the resistance of a pile [−], load at the head of a pile [kN]
Parameters describing the M-K curve in the equation can be determined using the least square method directly from set of values {
After reorganizing equation (3) it is also possible to obtain a formula that describes inverse relation, which can be written as follows:
Curves described by equation (4) – (6) can also be schematically shown as in Fig. 1. Value of settlement corresponding with maximum skin friction
Figure 1.
Example of M-K curves [12]

As it has been previously stated, the parameters describing a continuous load-settlement curve can be obtained directly from the results of static load tests using the least square method. Results of static load tests conducted in a full range of loads by Energopol Szczecin S.A. [1] allowed for further verification of existing methods of obtaining M-K curve parameters with regard to using those parameters in the method of curve conversion [1, 11].
Assuming that the value of measurement inaccuracy is a constant value for every two consecutive points in a load-settlement relations it is possible to subtract the M-K equation (3) written for two consecutive points and therefore minimize the impact of measurement inaccuracy on a final result of curve approximation.
After subtracting equation (3) written for two consecutive points (
The analysis previously described by the authors [11] shows that the most important factor with regard to pile safety which is pile maximum bearing capacity can be accurately determined from different parts of the data set. For example by only using the first part of data set {
Figure 2.
Optimal values of M-K parameters for a pile 31–10L [1]

Figure 3.
M-K curve for a pile 31–10L [1]

Calculated and measured settlement for a pile 31 10L [1]
1600 | 1.2 | 1.575 |
2600 | 1.9 | 3.081 |
3200 | 2.4 | 4.308 |
3800 | 3.2 | 5.904 |
4100 | 4.1 | 6.892 |
4500 | 5.9 | 8.479 |
4750 | 7.1 | 9.668 |
4900 | 8.8 | 10.474 |
5100 | 9.4 | 11.673 |
5200 | 10 | 12.335 |
5800 | 14.6 | 17.492 |
6200 | 20 | 22.637 |
6500 | 24.9 | 28.011 |
6650 | 30 | 31.419 |
6800 | 35.2 | 35.482 |
6950 | 40 | 40.396 |
7100 | 45.2 | 46.435 |
7200 | 50 | 51.279 |
7300 | 60 | 56.964 |
7400 | 70 | 63.715 |
7500 | 80 | 71.837 |
7600 | 90 | 81.763 |
M-K method has been chosen as a basis of the proposed method of load-settlement curve conversion due to the relations between parameters describing curves
The idea of curve conversion can be schematically described, as shown in Fig. 4.
Figure 4.
Idea of curve conversion

In previously published paper [15] authors have described the method of Q-s curve conversion based on linear elasticity theory. However, due to the method being based on linear elasticity theory, it applies only to a small range of loads for which load-settlement relation can approximate as a straight line. In practice, most pile loads are in the non-linear part of the load-settlement curve. Other research conducted by the authors published in [1, 16], indicate the possibility of conversion in a full range of loads both in the linear and non-linear part of the Q-s curve.
In order to the describe static load test curve for any given pile firstly it is necessary to determine the parameters of the curve concerning total resistance, which means κ average resistance along the pile skin [MPa]; cone resistance at the level pile base [MPa]; pile length [m]; pile diameter [m]; technological parameter.
Results of static load tests conducted in a full range of loads that have been conducted by Energopol Szczecin S.A. [1] were used to determine the relation that can be used for conversion of a maximum bearing capacity value in case of changed length and diameter:
In Tab. 3 we can see comparison between calculated from equation (17)
Calculated and measured values of maximum pile-bearing capacity
|
|||||
---|---|---|---|---|---|
1 | 27.5 | 6490 | 7127 | 1.09 | |
2 | 13.75 | 7700 | 8434 | 1.09 | |
1.5 | 21 | 11900 | 9984 | 0.84 | |
2 | 13.75 | 8260 | 8434 | 1.02 | |
1 | 27.5 | 6350 | 7126 | 1.12 | |
1.5 | 22.33 | 11780 | 11124 | 0.94 | |
1.5 | 22.33 | 12150 | 11124 | 0.92 |
It is also possible to inverse above-mentioned equation (17) and in the case of a known value of the maximum bearing capacity of a pile calculate cone resistance at the level of its base.
The method of static load curve conversion is based on the assumption that the change in pile length or diameter would result in a change of M-K parameters, which represents aggregated soil conditions. Firstly, we has to determine parameters describing pile-soil interaction for a pile that has been tested. As previously described, this can be achieved by using the least square method. Those parameters are called state”0” of a pile which represents the pile for which static load tests were conducted. Using the method of conversion, we obtain state “1” of a pile which represents the pile after curve conversion with calculated parameters. Parameters of state “0” are going to be described by upper index 0 and state “1” with upper index 1.
Using previously mentioned research conducted by Meyer and Siemaszko [17] concerning calculating κ
And in the case when soil conditions do not change, it is possible to simplify formula (18):
Above mentioned equation holds true in the case of the plasticized zone under the pile toe being, as shown in Fig. 5.
Figure 5.
Plasticized zone under the pile toe [1]

Figure 6.
Complete description of load-settlement relation of a pile 31–10L using the M-K method

Pile-soil interaction as well as stresses distribution under the pile base have been the subject of many researches described among others by Dembicki et al. [18] which shows that stresses under the pile base have also an impact along the pile skin. As we can see in Fig. 4 stresses under pile base can have also an impact along the pile skin.
Analysis of those relations has led to the formulation of an equation that can be used for the conversion
Previously mentioned research conducted by the authors [1, 11,19] with regards to the maximum bearing capacity of a pile points to the relation between limit bearing capacity, pile dimensions and stresses at the pile base (17) can be rearranged in order to obtain a relation that can be used for conversion in a full range of loads:
Parameters that describe the curve of pile base resistance in state “1” can be calculated directly from formulas (13), (14) and (15). Lastly, after obtaining a full description of curves
For any given data set of static load test results {
In state”1” it is assumed that the length of a pile is changed from 27.5 m to 15 m and its diameter from 2 m to 1.0 m and that the soil condition does not change. From equations (19), (20) and (22) it is possible to determine parameters describing the M-K curve for new pile conversion assumed after conversion.
Figure 7.
Comparison between load-settlement relation in case of decreased length and diameter

Another practical application of the proposed is an analysis of a change in safety factor SF defined as the ratio between maximum bearing capacity of a pile and its load
If we assume the recommended value of settlement
Using parameters determined in equations (29), (30) and (31) in the case of conversion of pile 31-10L it is possible to describe the change of safety factor with regards to assumed values o recommended settlement for pile dimensions before and after curve conversion as shown in Fig. 8.
Figure 8.
Change of safety factor in cased of decreased length and diameter

For any given value of the recommended settlement, it is possible to determine the safety factor
As we can see both in Fig. 8 and Tab. 4 difference between safety factor became smaller for increased values of recommended settlement Such analysis can be used in pile optimization in order to find optimal pile dimensions that would satisfy recommended conditions in structural design with regard to pile foundations.
Comparison between values of safety factor in case of decreased length and diameter
1 | 7.89 | 4.84 |
1.2 | 6.77 | 4.23 |
1.4 | 5.97 | 3.79 |
1.6 | 5.37 | 3.47 |
1.8 | 4.90 | 3.21 |
2 | 4.53 | 3.01 |
2.2 | 4.22 | 2.84 |
2.4 | 3.97 | 2.70 |
2.6 | 3.75 | 2.58 |
2.8 | 3.57 | 2.48 |
3 | 3.41 | 2.39 |
3.2 | 3.26 | 2.31 |
3.4 | 3.14 | 2.24 |
3.6 | 3.03 | 2.18 |
3.8 | 2.93 | 2.13 |
4 | 2.84 | 2.08 |
4.2 | 2.76 | 2.03 |
4.4 | 2.69 | 1.99 |
4.6 | 2.62 | 1.95 |
4.8 | 2.56 | 1.92 |
5 | 2.50 | 1.89 |
5.2 | 2.45 | 1.86 |
5.4 | 2.40 | 1.83 |
5.6 | 2.35 | 1.80 |
5.8 | 2.31 | 1.78 |
6 | 2.27 | 1.76 |
6.2 | 2.23 | 1.74 |
6.4 | 2.20 | 1.72 |
6.6 | 2.17 | 1.70 |
6.8 | 2.14 | 1.68 |
7 | 2.11 | 1.67 |
7.2 | 2.08 | 1.65 |
7.4 | 2.05 | 1.64 |
7.6 | 2.03 | 1.62 |
7.8 | 2.00 | 1.61 |
8 | 1.98 | 1.60 |
8.2 | 1.96 | 1.58 |
8.4 | 1.94 | 1.57 |
8.6 | 1.92 | 1.56 |
8.8 | 1.90 | 1.55 |
9 | 1.89 | 1.54 |
The authors have presented a method of static load test curve conversion in a full range of loads. The analysis was based on the Meyer-Kowalow method of static load test curve interpretation [8] The proposed method applies for a total resistance curve conversion