Otwarty dostęp

Improvement of long segment ribosomal PCR amplification for molecular identification of Litylenchus crenatae mccannii associated with beech leaf disease

 oraz    | 17 mar 2020

Zacytuj

Beech leaf disease (BLD) is an emerging tree disease in the Northeast for American beech (Fagus grandifolia) trees in Ohio, Pennsylvania, New York and Connecticut. It was discovered first in 2012 near Lake Erie in the Cleveland Metroparks, region of Ohio (Pogacnik and Macy, 2016). The leaves that host BLD have noticeable symptoms of banded dark green to chlorotic lesions between veins that increase in intensity and nematode numbers from summer to autumn. Many American beech trees with BLD may die eventually and this loss would devastate the beech-maple forest ecosystems of the eastern USA. The etiology was not understood (Ewing et al., 2019) until recently when a nematode was demonstrated to be necessary for experimental symptom production (Carta et al., 2020). As the disease spreads, accurate identification of nematodes in new symptomatic trees is more important than ever to delimit and potentially contain the spread of the disease and to identify the nematode in surveys outside the USA where related species may exist.

Molecular and morphological taxonomic identifications were conducted in our lab with the nematodes isolated from the lesions of the BLD leaves collected in Fall, 2017 from Perry, Lake County, Ohio, USA by an Ohio Department of Agriculture nursery inspector from ailing American beech trees Fagus grandifolia (Fall specimens). Their ribosomal DNA (rDNA) loci were amplified by PCR with the one primer set and an enhanced DNA polymerase system, and the resulting 3.5 kb (18 S, ITS and 28 S) rDNA amplicons were directly sequenced (Carta and Li, 2019). Morphological evaluation and an initial GenBank search revealed that this was an unknown species in the genus Litylenchus. Shortly after this discovery, a Litylenchus nematode from leaf galls of Fagus crenata in Japan was described as Litylenchus crenatae (Kanzaki et al., 2019), showing a few different DNA base pairs from the nematode population we sequenced. Based on these molecular, morphological and host range differences, a new subspecies Litylenchus crenatae mccannii was described (Carta et al., 2020).

Special handling of nematodes in PCR reactions is needed because of potential molecular marker variation within and between individual nematodes, plus their often tiny size and chemically resistant cuticle that may create unexpected challenges. Among more than 40 Litylenchus specimens from the samples collected from Ohio and Pennsylvania during the summer of 2018, 35 specimens with no PCR bands for the 3.5 kb target were observed, and the rest failed to yield a long enough target for downstream sequencing. This report describes a significant technical improvement beyond previous efforts (Carta and Li, 2018, 2019) to more reliably amplify the 3.5 kb long rDNA target and increase the PCR yield for the crude, unpurified DNA extracts of single nematodes by utilizing proofreading DNA polymerase in an optimized solution. This is important because it is impractical in a nematode diagnostic laboratory to efficiently produce very clean DNA with a kit from only one or a few specimens.

Commonly used Taq DNA polymerase lacks proofreading ability, which limits the length of the amplicon, usually up to 2.9 kb (Arezi et al., 2003; Tindall and Kunkel, 1988). It has been demonstrated that long template DNA could be amplified successfully by adding a thermal proofreading DNA polymerase with 3’ to 5’ exonuclease activity to a Taq PCR system (Barnes, 1994; Cheng et al., 1995). As a result, many PCR amplification systems have been developed and made commercially available by blending a Taq polymerase and a thermal proofreading DNA polymerase supplied with a specially optimized PCR buffer. Two Taq-based blend systems, TaKaRa Ex Taq® DNA Polymerase (a blend of TaKaRa Taq® DNA Polymerase and an unspecified proofreading DNA polymerase) and PicoMaxx™ High Fidelity PCR System (a blend of Taq2000™ DNA polymerase, cloned Pfu DNA polymerase and ArchaeMaxx® polymerase enhancing factor) were selected and tested in this study.

Materials and methods

Live Litylenchus specimens were isolated from the banding lesions of American beech leaves with BLD as described in Table 1, after the leaves were dissected, and followed by water extraction. Some of the specimens were also imaged as vouchers for morphological and morphometrical analysis. The preparation of the crude and unpurified genomic DNA from a live single Litylenchus and the visualization, cleanup and direct DNA sequencing, including sequencing primers, of the PCR products were performed by using the procedures described in previous studies (Carta and Li, 2018, 2019).

Litylenchus crenatae specimens from American beech trees (Fagus grandifolia) with BLD tested in this study.

Specimens Locality Part Session
104H78, 104H81, 104H82, 104H83, 104H84, 104H85, 104H86, 104H87, 104H88, 104H89 and 104H90 Lake County, Ohio Leaf Fall (November, 2017)
104J54, 104J55, 104J56 and 104J57 Cuyahoga County, Ohio Leaf Summer (May, 2018)
104K17, 104K18, 104K19 and 104K20 The Holden Arboretum, Kirtland, Ohio Leaf Summer (August, 2018)
104K25, 104K26, 104K27, 104K28, 104K29, 104K30 and 104K31 Potter County, Pennsylvania Leaf Summer (August, 2018)
104K37, 104K38 and 104K39 Crawford County, Pennsylvania Leaf Summer (August, 2018)
104N95, 104N96 and 104N97 The Holden Arboretum, Kirtland, Ohio Bud Spring (March, 2019)

Either the 3.5 kb long segment or the 1.7 or 1.9 kb medium segment ribosomal amplifications by PCR with DreamTaq™ Hot Start DNA polymerase system (DreamTaq™, Thermo Fisher Scientific, Waltham, MA) were performed by using the procedures, including primer sets, 18S-CL-F3 and 28S-CL-R for the 3.5 kb ribosomal loci, 18S-CL-F3 and 18S-CL-R7 for the 18 S locus (1.7 kb) and ITS-CL-F2 and 28S-CL-R for the ITS-28S (D1D2D3) loci (1.9 kb) described in the previous study (Carta and Li, 2019) unless otherwise noted.

Assembling PCR buffer and parameterizing thermal cycling conditions in the following amplifications with different DNA polymerases were performed according to each respective manufacturers’ guidance. Treatment components are summarized in Table 2, and cycling conditions in Tables 3 and 4.

PCR components and setup.

Platinum™ Taq (10 units/μl) Taq2000™ (5 units/μl) DreamTaq™ (5 units/μl) TaKaRa Ex Taq™ (5 units/μl) or combined with DreamTaq™ (5 units/μl) PicoMaxx™ System (5 units/μl) or combined with DreamTaq™ (5 units/μl) pfu DNA polymerase (2.5 units/μl) or combined with DreamTaq™ (5 units/μl) Herculase® II Fusion DNA polymerase Phusion™ High-Fidelity DNA Polymerase (2 units/μl) Pwo DNA polymerase (5 units/μl) or combined with DreamTaq™ (5 units/μl)
Water (μl) Mixture A: 7.6
Water (μl) 15.375 16 16.375/16.25 15.875 or 15.75 17.3 or 17.175 17.05/17.55 or 16.925/17.425 16 14.5 Mixture B: 9.875 (or 9.75)
10 or 5x proprietary buffer (μl) 2.5 2.5 2.5 2.5 2.5 2.5 5 5 Mixture A: 2.5
50 mM MgCl2 (μl) 1 0.25
100 mM dNTP (25 mM each) (μl) 0.2 0.2 0.25 Mixture B: 0.4
10 mM dNTP (2.5 mM each) (μl) 2 0.5
8 mM dNTP (2 mM each) (μl) 2.5 2.5 2.5
10 μm Forward primer (μl) 0.75 0.75 0.75 1.25 1.25 1.25 0.625 1.25 Mixture B: 1.25
10 μm Reverse primer (μl) 0.75 0.75 0.75 1.25 1.25 1.25 0.625 1.25 Mixture B: 1.25
DMSO 0.25
DNA template (μl) 2 2 2 2 2 2 2 2 Mixture B: 2
Proprietary DNA polymerase(s) (μl) 0.125 0.25 0.125/0.25 0.125 or plus DreamTaq™: 0.125 0.5 or plus DreamTaq™: 0.125 0.75/0.25 or plus DreamTaq™: 0.125 0.5 0.25 Mixture A: 0.125 or plus DreamTaq™: 0.125
Total reaction volume (μl) 25 25 25 25 25 25 25 25 12.5 each mixture

PCR cycling conditions.

Platinum™ Taq Taq2000™ DreamTaq TaKaRa Ex Taq™ or combined with DreamTaq PicoMaxx™ System or combined with DreamTaq
1. Initial denaturation 95°C for 3 min Sep 1: 1 cycle 95°C for 3 min Step 1: 1 cycle 95°C for 3 min Step 1: 1 cycle 98°C for 30 sec Step 1: 1 cycle 95°C for 2 min Step 1: 1 cycle
2. Denaturation 95°C for 30 sec Step 2, 3 and 4: 36 cycles 95°C for 30 sec Step 2, 3 and 4: 36 cycles 95°C for 30 sec Step 2, 3 and 4: 36 cycles 98°C for 10 sec Step 2 and 4: 36 cycles 95°C for 30 sec Step 2, 3 and 4: 36 cycles
3. Annealing 50°C for 45 sec 50°C for 45 sec 50°C for 45 sec 55°C for 45 sec
4. Extension 72°C for 3 min 72°C for 3 min 72°C for 3 min 68°C for 5 min 72°C for 5 min
5. Final extension 72°C for 7 min Step 5: 1 cycle 72°C for 7 min Step 5: 1 cycle 72°C for 7 min Step 5: 1 cycle 72°C for 7 min Step 5: 1 cycle 72°C for 7 min Step 5: 1 cycle

PCR cycling conditions.

No. Step pfu or combined with DreamTaq Herculase® II Phusion™ Pwo or combined with DreamTaq
1. Initial denaturation 95°C for 2 min Step 1: 1 cycle 95°C for 2 min Step 1: 1 cycle 95°C for 2 min Step 1: 1 cycle 95°C for 2 min Step 1: 1 cycle
2. Denaturation 95°C for 30 sec Step 2, 3 and 4: 36 cycles 95°C for 20 sec Step 2, 3 and 4: 36 cycles 95°C for 20 sec Step 2, 3 and 4: 36 cycles 95°C for 30 sec Step 2, 3 and 4: 36 cycles
3. Annealling 55°C for 45 sec 55°C for 20 sec 55°C for 20 sec 57°C for 45 sec
4. Extension 72°C for 5 min 72°C for 2 min 15 sec 72°C for 2 min 15 sec 72°C for 5 min
5. Final extension 72°C for 7 min Step 5: 1 cycle 72°C for 7 min Step 5: 1 cycle 72°C for 7 min Step 5: 1 cycle 72°C for 7 min Step 5: 1 cycle
Platinum™ Taq DNA polymerase

Each PCR amplification with Platinum™ Taq DNA Polymerase (Platinum™ Taq) (Thermo Fisher Scientific, Waltham, MA) was carried out in a 25 μl of mixture containing Platinum™ Taq (10 units/μl) 0.125 μl, 10X PCR Buffer Mg 2.5 μl, MgCl2 (50 mM) 1 μl, dNTP (2.0 mM each) 2.5 μl, Template DNA 2 μl, forward primer (10 μm) 0.75 μl and reverse primer (10 μm) 0.75 μl for either primer set 18S-CL-F3 and 28S-CL-R or ITS-CL-F2 and 28S-CL-R, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 15.375 μl. The thermal cycling program was one cycle of 95°C for 3 min; 36 cycles of 95°C for 30 sec, 50°C for 45 sec, 72°C for 3 min; and final extension at 72°C for 7 min.

Taq2000™ DNA polymerase

Each PCR amplification with Taq2000™ DNA Polymerase (Agilent, Santa Clara, CA) was carried out in a 25 μl mixture containing Taq2000™ (5 units/μl) 0.25 μl, 10X PCR Buffer 2.5 μl, MgCl2 (50 mM) 0.25 μl, dNTP (2.0 mM each) 2.5 μl, Template DNA 2 μl, both forward primer (10 μm) 0.75 μl and reverse primer (10 μm) 0.75 μl for either primer set 18S-CL-F3 and 28S-CL-R or ITS-CL-F2 and 28S-CL-R, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 16 μl. The thermal cycling program was one cycle of 95°C for 3 min; 36 cycles of 95°C for 30 sec, 50°C for 45 sec, 72°C for 3 min; and final extension at 72°C for 7 min.

TaKaRa Ex Taq™ DNA polymerase or combined with DreamTaq

Each PCR amplification with TaKaRa Ex Taq™ DNA Polymerase (Takara Bio USA, Inc., Mountain View, CA) alone or combined with DreamTaq™ was carried out in a 25 μl of mixture containing TaKaRa Ex Taq™ (5 units/μl) 0.125 μl (or plus DreamTaq™ (5 units/μl) 0.125 μl), 10X Ex Taq Buffer 2.5 μl, dNTP (2.5 mM each) 2 μl, Template DNA 2 μl, forward primer 18S-CL-F3 (10 μm) 1.25 μl, reverse primer 28S-CL-R (10 μm) 1.25 μl, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 15.875 μl (or 15.75 μl). The thermal cycling program was: one cycle of 98°C for 30 sec; 36 cycles of 98°C for 10 sec, 68°C for 5 min; and final extension at 72°C for 7 min.

PicoMaxx™ High Fidelity PCR System alone or combined with DreamTaq

Each PCR amplification with PicoMaxx™ High Fidelity PCR System (PicoMaxx™ System) (Agilent, Santa Clara, CA) alone or combined with DreamTaq™ was carried out in a 25 μl of mixture containing PicoMaxx™ high fidelity PCR system (PicoMaxx™ (5 units/μl)) 0.5 μl (or plus DreamTaq™ (5 units/μl) 0.125 μl), 10× PicoMaxx™ reaction buffer (PicoMaxx™ buffer) 2.5 μl, dNTP (25 mM each) 0.2 μl, Template DNA 2 μl, forward primer 18S-CL-F3 (10 μm) 1.25 μl, reverse primer 28S-CL-R (10 μm) 1.25 μl, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 17.3 μl (or 17.175 μl). The thermal cycling program was one cycle of 95°C for 2 min; 36 cycles of 95°C for 30 sec, 55°C for 45 sec, 72°C for 5 min; and final extension at 72°C for 7 min.

pfu DNA polymerase alone or combined with DreamTaq™:

Each PCR amplification with pfu DNA polymerase (Agilent, Santa Clara, CA) alone or combined with DreamTaq™ was carried out in a 25 μl of mixture containing pfu (2.5 units/μl) 0.75 μl (or plus DreamTaq™ (5 units/μl) 0.125 μl), 10× Pfu reaction buffer, 10× PicoMaxx™ buffer, or 10× DreamTaq™ buffer 2.5 μl, dNTP (25 mM each) 0.2 μl, Template DNA 2 μl, forward primer 18S-CL-F3 (10 μm) 1.25 μl, reverse primer 28S-CL-R (10 μm) 1.25 μl, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 16.85 μl (or 16.725 μl). The thermal cycling program was one cycle of 95°C for 2 min; 36 cycles of 95°C for 30 sec, 55°C for 45 sec, 72°C for 5 min; and final extension at 72°C for 7 min.

Pwo DNA polymerase alone or combined with DreamTaq

Each PCR amplification with Pwo DNA polymerase (Sigma-Aldrich, St Louis, MO) alone or combined with DreamTaq™ was carried out in a 25 μl final volume consisting of two mixtures: 12.5 μl of mixture A containing Pwo (5 units/μl) 0.125 μl (or plus DreamTaq (5 units/μl) 0.125 μl), 10× Pwo reaction buffer or 10× PicoMaxx™ buffer 2.5 μl, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 9.875 μl (or 9.75 μl); 12.5 μl of mixture B containing dNTP (25 mM each) 0.4 μl, template DNA 2 μl, forward primer 18S-CL-F3 (10 μm) 1.25 μl, reverse primer 28S-CL-R (10 μm) 1.25 μl. The thermal cycling program was one cycle of 95°C for 2 min; 36 cycles of 95°C for 30 sec, 57°C for 45 sec, 72°C for 5 min; and final extension at 72°C for 7 min.

Herculase® II Fusion DNA polymerase

Each PCR amplification with Herculase® II Fusion DNA polymerase (Agilent, Santa Clara, CA) was carried out in a 25 μl of mixture containing Herculase® II Fusion DNA polymerase 0.5 μl, 5× reaction buffer 5 μl, dNTP (25 mM each) 0.25 μl, Template DNA 2 μl, forward primer 18S-CL-F3 (10 μm) 0.625 μl, reverse primer 28S-CL-R (10 μm) 0.625 μl, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 16 μl. The thermal cycling program was: one cycle of 95°C for 2 min; 36 cycles of 95°C for 20 sec, 55°C for 20 sec, 72°C for 2 min 15 sec; and final extension at 72°C for 7 min.

Phusion™ High-Fidelity DNA polymerase

Each PCR amplification with Phusion™ High-Fidelity DNA Polymerase (Thermo Fisher Scientific, Waltham, MA) was carried out in a 25 μl of mixture containing Phusion™ High-Fidelity DNA Polymerase (2 units/μl) 0.25 μl, 5× reaction buffer 5 μl, dNTP (2.5 mM each) 0.5 μl, Template DNA 2 μl, forward primer 18S-CL-F3 (10 μm) 1.25 μl, reverse primer 28S-CL-R (10 μm) 1.25 μl, DMSO 0.25 μl, and molecular biology grade water (Sigma-Aldrich, St Louis, MO) 14.5 μl. The thermal cycling program was: one cycle of 95°C for 2 min; 36 cycles of 95°C for 20 sec, 55°C for 20 sec, 72°C for 2 min 15 sec; and final extension at 72°C for 7 min.

Results

A summary of the PCR evaluations below based on specificity, efficiency and fidelity is given in Table 5 for individual polymerase systems, and in Table 6 for combined polymerase systems. Figure 1 shows that the successful 3.5 kb long segment PCR amplifications by the 18S-CL-F3 and 28S-CL-R primer set and the DreamTaq™ system were carried out in 10 out of 11 Fall specimens. The direct sequencing for the three loci (3.5 kb) was also conducted successfully in all specimens, except for 104H89 and 104H90 with low PCR yields that were good for sequencing only one or two loci. The 3.5 kb rDNA sequences generated for the specimens, 104H82 ( MN525396) and 104H83 (MN525397) were submitted to GenBank. This result shows that DreamTaq™ had the ability to amplify the 3.5 kb target in most Fall specimens within the size limit by Taq DNA polymerase up to 3 to 4 kb on amplicon (Erlich et al., 1991; Innis et al., 1988). However, failures (no yield for the 3.5 kb target) were observed in most Summer specimens (Fig. 2A, Fig. 3A, Fig. 4A). One possibility for this failure was amplicon size limitation associated with DreamTaq™ in these less mature Summer specimens. In order to address this issue, two medium segment PCR amplifications were carried out with DreamTaq™ and two primers sets, 18S-CL-F3/18S-CL-R7and ITS-CL-F2/28S-CL-R, which amplify the 18 S locus (1.7 kb), and ITS and 28 S loci (1.9 kb) within the 3.5 kb target, respectively. The amplifications showed that DreamTaq™ can amplify both medium 1.7 kb and 1.9 kb fragments with high yield (Fig. 2B, 2C), but not the 3.5 kb long targets (Fig. 2A) in these Summer specimens. This indicates that the amplification failure of the 3.5 kb long segment PCR in these Summer specimens is due to the size limitation of DreamTaq™ polymerase.

Summary of PCR performance of Individual DNA polymerases (systems) tested in this study.

Platinum™ Taq Taq2000™ DreamTaq TaKaRa Ex Taq PicoMaxx™ System pfu Pwo Herculase® II Phusion™
Spring specimens 3.5 kb: X; 1.9 kb: √/X 3.5 kb: X; 1.9 kb: √√√√/X 3.5 kb: X; 1.9 kb: √√√√ na na na na na na
Summer specimens na 3.5 kb: X (DNS); 1.9 kb: √√√ (DNS) 3.5 kb: X or X/√ (DNS); 1.7Kb: √√√√/X; 1.9 kb: √√√√/X 3.5 kb: √√/X or X 3.5 kb: √√/X or X 3.5 kb: X (DNS) 3.5 kb: X (DNS) 3.5 kb: X 3.5 kb: X
Fall specimens na na 3.5 kb: √√√/X; 1.9 kb: NA na na na na na na

Notes: DNS, data not shown. The middle segments, 1.7 and 1.9 kb were not tested in all specimens, unless otherwise noted. X: An unsuccessful PCR amplification. It was defined practically as: weak or no target PCR bands (yields) on the Lonza gels. For example, weak target PCR bands shown Lane 1 and 2 in Figure 7B, which could not provide sufficient templates for downstream direct DNA sequencing. √: A successful PCR amplification. It was defined practically based on the observations from our routine direct DNA sequencing as: the amount of resulting target amplicon in the 25 μl of PCR reaction is good for at least 6 sequencing reactions (√) in downstream direct DNA sequencing, for example, the target PCR band shown on the Lonza gel on lane 11, in Figure 1 is good for at least 6 sequencing reactions (√), while each of the strong target PCR bands shown on the Lonza gel on lane 1 to 7 and 9 in Figure 1 is good for at least 18 sequencing reactions (√√√). /X: In a test or repeating tests, most PCR amplifications were successful and only one or few were unsuccessful. /√: In a test or repeating tests, most PCR amplifications were unsuccessful and only one or few were successful

Figure 7:

Long range ribosomal PCR Amplifications of the 3.5 kb target from Summer specimens with both DreamTaq™ and Pfu in manufacturer’s PCR buffers. M: DNA markers; 1: 104K29; 2: 104K30; 3: 104K31; NC: negative control, respectively. A: DreamTaq™ PCR buffer; B: Pfu PCR buffer.

Summary of PCR performance of blended DNA polymerases (systems) tested in this study.

TaKaRa Ex Taq™ combined with DreamTaq™ in TaKaRa Ex buffer PicoMaxx™ System combined with DreamTaq™ in PicoMaxx™ buffer DreamTaq™ in PicoMaxx™ buffer pfu in PicoMaxx™ buffer Pfu combined with DreamTaq™ in PicoMaxx™ buffer pfu combined with DreamTaq™ in DreamTaq™ buffer pfu combined with DreamTaq™ in pfu buffer Pwo in PicoMaxx™ buffer Pwo combined with DreamTaq™ in Pwo buffer Pwo combined with DreamTaq™ in PicoMaxx buffer
Spring specimens na na na na na na na na na na
Summer specimens 3.5 kb: X 3.5 kb: √√√/X 3.5 kb: √/X or X 3.5 kb: X 3.5 kb: √√√√ or √√ 3.5 kb: X 3.5 kb: X 3.5 kb: X 3.5 kb: X (DNS) 3.5 kb: √/X
Fall specimens na na na na na na na na na na

Note: See the notes in Table 5.

Figure 1:

Long range ribosomal PCR Amplifications of the 3.5 kb target from Fall specimens with DreamTaq™. M: DNA markers; 1: 104H78; 2: 104H81; 3: 104H82; 4: 104H83; 5: 104H84; 6: 104H85; 7: 104H86; 8: 104H87; 9: 104H88; 10: 104H89; 11: 104H90; NC: negative control. 1-7: Female; 8-11: Male.

Figure 2:

Long range ribosomal PCR Amplifications of the 3.5 kb target from Summer specimens with TaKaRa Ex Taq® system. M: DNA markers; 1: 104J54; 2: 104J55; 3: 104J58; 4: 104J59; NC: negative control, respectively. A: DreamTaq™; B: 18 S locus (1.7 kb) by DreamTaq™, C: ITS and 28 S loci (1.9 kb) by DreamTaq™; D: TaKaRa Ex Taq® system.

Figure 3:

Long range ribosomal PCR Amplifications of the 3.5 kb target from Summer specimens with PicoMaxx™ High Fidelity PCR System. M: DNA markers; 1: 104K17; 2: 104K18; 3: 104K19; 4: 104K20; NC: negative control, respectively. A: DreamTaq™; B: PicoMaxx™ High Fidelity PCR System.

Figure 4:

Long range ribosomal PCR Amplifications of the 3.5 kb target from Summer specimens with PicoMaxx™ High Fidelity PCR System. M: DNA markers; 1: 104K25; 2: 104K26; 3: 104K27; 4: 104K28; 5: 104K29; 6: 104K30; 7: 104K31; NC: negative control, respectively. A: DreamTaq™; B: PicoMaxx™ High Fidelity PCR System.

Both TaKaRa Taq® and PicoMaxx™ systems can amplify the 3.5 kb target in some of the Summer specimens in which the DreamTaq™ failed (compare Fig. 2A with 2D and Fig. 3A with 3B). However, they also failed to amplify the 3.5 kb target in other Summer specimens (Fig. 4B; Fig. 9A (Lanes 5, 6, 7)). In order to establish a system to amplify the 3.5 kb target regardless of the variations of specimens, DreamTaq™ and PicoMaxx™ were combined to test if both work together to overcome this difficulty during the long segment PCR. In Figure 5A, 5B, DreamTaq™ demonstrated again its ability to amplify both 1.7 kb and 1.9 kb medium segment fragments within the 3.5 kb target in the difficult specimens. Figure 5C shows the robust amplifications of the 3.5 kb target for these specimens by the combination of DreamTaq™ and the PicoMaxx™ System, which suggests it is the proofreading ability by Pfu in PicoMaxx™ that greatly facilitates DreamTaq™. In order to elucidate the synergy between the two, reconstituting DreamTaq™ and the Pfu used in the PicoMaxx™ System was conducted. In the presence of the PicoMaxx™ buffer for these difficult specimens (Fig. 6), the DreamTaq™ alone barely amplified the 3.5 kb target (Lanes 1, 2, 3, Fig. 6). The proofreading Pfu by itself failed to amplify the product (Lanes 5, 6, 7, Fig. 6), but combining the DreamTaq™ and the Pfu delivered a robust amplification (Lanes 9, 10, 11, Fig. 6). We tested whether the combination works in the presence of either DreamTaq™ buffer or Pfu buffer. However, neither of them could facilitate the combination (Fig. 7A, 7B). This suggests that a long segment PCR may not be achieved by simply blending a Taq with a proofreading DNA polymerase, but the PCR buffer must be taken into account as well. In this system (Lanes 9, 10, 11, Fig. 6), the three proprietary components, DreamTaq™, Pfu and PicoMaxx™ buffer must be purchased separately, which is not economical. Therefore, the combination of DreamTaq™ and PicoMaxx™ High Fidelity PCR System (Taq, Pfu and buffer) seen in Figure 5C is the preferable option to address difficult specimens.

Figure 9:

PCR performance of TaKaRa Ex Taq® system and PicoMaxx™ High Fidelity PCR System. M: DNA markers; 1 and 5: 104K37; 2 and 6: 104K38; 3 and 7: 104K39; 4 and 8: 104K40. A: 1, 2, 3 and 4: TaKaRa Ex Taq® system; 5, 6, 7 and 8: PicoMaxx™ High Fidelity PCR System; B: 1, 2, 3 and 4: TaKaRa Ex Taq® system and DreamTaq™; 5, 6, 7 and 8: PicoMaxx™ High Fidelity PCR System. NC: negative control, respectively.

Figure 5:

Long range ribosomal PCR Amplifications of the 3.5 kb target from Summer specimens with DreamTaq™ and PicoMaxx™ High Fidelity PCR System. M: DNA markers; 1: 104K25; 2: 104K26; 3: 104K27; 4: 104K28; 5: 104K29; 6: 104K30; 7: 104K31; NC: negative control, respectively. A: 18 S locus (1.7 kb) by DreamTaq™, B: ITS and 28 S loci (1.9 kb) by DreamTaq™; C: DreamTaq™ and PicoMaxx™ High Fidelity PCR System combined.

Figure 6:

Long range ribosomal PCR Amplifications of the 3.5 kb target from Summer specimens with DreamTaq™ or/and Pfu in PicoMaxx™ buffer. M: DNA markers; 1, 2, 3 and 4: DreamTaq™; 5, 6, 7 and 8: Pfu; 9, 10, 11and 12: DreamTaq™ and Pfu combined; 1, 5 and 9: 104K29; 2, 6 and 10: 104K30; 3, 7 and 11: 104K31; 4, 8 and 12: negative control (NC), respectively.

Pwo (derived from Pyrococcus woesei), another proofreading DNA polymerase, was tested in line with the Pfu in PicoMaxx™ buffer. Figure 8 shows that in the presence of the PicoMaxx™ buffer, both combinations (Lanes 1, 2, 3 ,4, 5, 6 in Fig. 8B) are better than either Pwo or DreamTaq™ alone (Lanes 1, 2, 3 ,4, 5, 6 in Fig. 8A), and the combination with Pfu performed better than the combination with Pwo (Fig. 8B). The presence of either DreamTaq™ buffer or Pwo buffer was also evaluated for the combination of DreamTaq™ and Pwo in a different specimen from beech buds collected in the spring of 2019 (Spring specimens). No significant amplifications of the 3.5 kb target were seen in the presence of either buffer (data not shown). This confirms again that PCR buffer is another key to the success of the DreamTaq™ and Pfu or Pwo combination.

Figure 8:

PCR performance of Pfu and Pwo in PicoMaxx™ buffer. M: DNA markers; 1 and 4: 104K37; 2 and 5: 104K38; 3 and 6: 104K39. A: 1, 2 and 3: DreamTaq™; 4, 5 and 6: Pwo (0.125 μl per reaction). B: 1, 2 and 3: DreamTaq™ and Pfu; 4, 5 and 6: DreamTaq™ and Pwo (0.125 μl per reaction). NC: negative control, respectively. Note: final concentration of Pfu in each reaction was aligned with Pwo and DreamTaq™ in 0.625 units.

The comparison between TaKaRa Ex Taq® system and PicoMaxx™ system was also performed. Figure 9A shows that both PicoMaxx and TaKaRa Ex Taq® systems failed to amplify the 3.5 kb target, but the PicoMaxx™ system gave DreamTaq™ dramatic leverage over the TaKaRa Ex Taq® system (Fig. 9B), and again the combination of DreamTaq™ and the PicoMaxx™ System demonstrated its robust long segment PCR amplification in the difficult specimens.

Fusion DNA polymerase is an engineered fusion of a proofreading polymerase and a processivity-enhancing domain (Ishino and Ishino, 2014) and offers tremendous advantages over traditional Taq with high fidelity, robust amplification in low abundance, high GC, and other difficult targets, short extension times (1.0 kb/10-15 sec) and ability to amplify long target (>20 kb) (both Agilent and Thermo Fisher Scientific web sites). Herculase® II Fusion DNA polymerase and Phusion™ High-Fidelity DNA Polymerase were tested. Figure 10 shows both could not produce any 3.5 kb target bands except for the smear band by the Herculase® II Fusion DNA polymerase.

Figure 10:

PCR performance of Herculase® II Fusion DNA polymerase and Phusion™ High-Fidelity DNA Polymerase. M: DNA markers; 1 and 5: 104K37; 2 and 6: 104K38; 3 and 7: 104K39; 4 and 8: 104K40. 1, 2, 3 and 4: Herculase® II Fusion DNA polymerase; 5, 6, 7 and 8: Phusion™ High Fidelity PCR System; NC: negative control, respectively.

The PCR performances of Taq2000™, which is one of the components of the PicoMaxx™ system, Platinum™ Taq and DreamTaq™ were also compared in Spring specimens. In the presence of their own buffers, both the long segment PCR for the 3.5 kb target and the medium range PCR for the 1.9 kb target were carried out. In the long segment PCR amplifications, all of the three Taqs failed to amplify the 3.5 kb target (Fig. 11A). In the medium segment PCR amplifications, the Platinum™ Taq weakly amplified the 1.9 kb target (Lanes 5, 6 in Fig. 11B), the Taq2000™ was able to amplify two specimens successfully (Lanes 2, 3 in Fig. 11B), and the DreamTaq™ outperformed either the Platinum™ Taq or Taq2000™ in all three specimens (Lanes 7, 8, 9 in Fig. 11B). This indicates that DreamTaq™ has better sensitivity in this situation than either the Platinum™ Taq or Taq2000™. It also further explains why combining the PicoMaxx™ system (PicoMaxx™ and PicoMaxx™ buffer) and DreamTaq™ can successfully amplify the 3.5 kb target in the specimens where both DreamTaq™ and PicoMaxx™ systems failed separately.

Figure 11:

PCR performance of Taq2000™, Platinum™ Taq and DreamTaq™. M: DNA markers; 1, 4 and 7: 104N95; 2, 5 and 8: 104N96; 3, 6 and 9: 104N97. 1, 2, 3 and NC by Taq2000™; 4, 5, 6 and NC by Platinum™ Taq; 7, 8, 9 and NC by DreamTaq™, NC: negative control, respectively. A: 3.5 kb target; B: 1.9 kb ITS and 28 S target. Note: final concentration of either Taq2000™ or DreamTaq™ in each reaction was aligned with Platinum™ Taq in 1.25 units.

The 3.5 kb targets amplified by the Taq-based blend systems, TaKaRa Ex Taq® DNA Polymerase in the specimen 104J58 (OH), PicoMaxx™ High Fidelity PCR System in the Summer Specimen 104K17 (OH); by the combination of DreamTaq™ and PicoMaxx™ High Fidelity PCR System in the Summer specimens, 104K25 (Potter County, PA) and 104K37 (Crawford County, PA) were sequenced and the resulting rDNA sequences (ITS and 28 S loci) were deposited in GenBank with the accession numbers, 104H82, MN525396; 104H83, MN525397; 104J58 MN525398; 104K17, MN525399; 104k25, MN525400; 104K37, MN525401, respectively. Multiple alignments of these sequences above with the 3.5 kb rDNA (MK292137 and MK292138) of the Ohio Litylenchus specimens in the previous study (Carta and Li, 2019) reveal that the ITS and 28 S (D1D2D3) sequences of the Pennsylvania specimens are 100% identical to the Ohio specimens.

Discussion

The molecular taxonomic identifications performed in this study not only confirmed that the nematodes discovered in BLD leaves from Ohio and Pennsylvanian are the same species of Litylenchus crenatae mccannii, but they also demonstrated a technical improvement to achieve consistent amplification of the 3.5 kb ribosomal PCR product through long segment PCR amplification using sometimes variable quality crude genomic DNA extracts as template.

We observed that most Fall specimens were mature and not very active, but with highly developed reproductive systems containing many germ cells. In contrast, most Summer specimens were young, motile adults with a poorly developed reproductive system. The cuticle is the first barrier for proteinase K to lyse in a nematode which is relatively tough and resistant to environmental forces in young adults, but loose, wrinkled, permeable and susceptible to environmental insults in older adults (Searcy et al., 1976; Davies and Curtis, 2011; Herndon et al., 2017). These differences mean the Fall Specimen nematode cuticles are more easily broken down by proteinase K to release more genomic DNA. This is especially favorable for long DNA fragments (i.e. larger than 3.5 kb) which have more unlysed debris and impurities than fragments found in younger Summer specimens. Thus, both the quantity of the 3.5 kb target template and the debris and impurities in the crude unpurified genomic DNA lysates may vary from session to session and specimen to specimen. This phenomenon was demonstrated by the successful amplification of the 3.5 kb target by DreamTaq™ in Fall specimens (Fig. 1), but not in the Summer specimens (Figs. 1A and 2A). The debris or impurities in the incomplete genomic DNA lysates from Summer specimens may interfere with the PCR extension of the 3.5 kb target by increasing the probability of incorporating wrong nucleotides and consequently increasing the size limitation associated with DreamTaq™ and eventually failing the 3.5 kb long segment PCR, but not the medium segment PCR amplification (Fig. 2A, 2B, 2C). This failure can be prevented by a proofreading DNA polymerase (either TaKaRa Ex Taq® system or the PicoMaxx™ system) in these Summer specimens (Figs. 2D and 3B).

When both DreamTaq™ and these Taq-based blend systems failed (Fig. 4), both the low quantity of the 3.5 kb long fragments and the debris and impurities in the input DNA were the apparent causes. These double failures were prevented by employing both DreamTaq™ and the PicoMaxx™ system (Fig. 5C). Per the vendor’s information, DreamTaq™ DNA Polymerase could amplify a target from as low as 3 pg of purified human genomic DNA, and provided higher sensitivity compared to six other Taq DNA polymerases, including TaKaRa Taq® DNA Polymerase (a component of the TaKaRa Ex Taq® system). DreamTaq™ also demonstrated its higher sensitivity than either Taq2000™ or Platinum™ Taq (Fig. 11B). The failures of the PicoMaxx™ system were caused by the low sensitivity of its Taq2000™ DNA polymerase and were reversed by adding DreamTaq™ (Figs. 5C and 9B) because of its high sensitivity. The direct synergy between DreamTaq™ and proofreading Pfu, the key component in the PicoMaxx™ system, is further confirmed in Figure 6. In the combination of DreamTaq™ and the PicoMaxx™ system, DreamTaq™ and proofreading Pfu worked synergistically only in the presence of PicoMaxx™ buffer (Fig. 6 Lanes 9, 10, 11, Fig. 7A, 7B). Both Pfu and Pwo were also compared directly in this study (Fig. 8). The synergy with DreamTaq™ was not supported by either of their own buffers, but PicoMaxx™ buffer allowed Pfu to perform more robustly than Pwo. Therefore, the PCR buffer is also required for successful synergy between DreamTaq™ and Pfu or Pwo. Tests in two Fusion DNA polymerases suggest Fusion DNA polymerases may not be suitable for crude unpurified genomic DNA in low quantity and quality although they have multiple advantages over traditional Taq (Fig. 10).

Taken together, the size limit to the 3.5 kb target by Taq, the low quantity of the 3.5 kb target template and the debris and impurities in the crude and unpurified genomic DNA lysates are three primary factors responsible for the failures of the 3.5 kb long PCR amplification in the Summer specimens. Establishing the combination of DreamTaq™ and the PicoMaxx™ system in this study well addressed the issues above for the 3.5 kb long segment ribosomal PCR amplification by combining the sensitivity of DreamTaq™, the proofreading of Pfu and the sensitivity and robustness of PicoMaxx™ buffer. In this study long segment ribosomal PCR amplification in various Litylenchus specimens has been achieved by this technical improvement. Successful long ribosomal PCR by this improvement was also conducted for other taxa, Ditylenchus sp. (Tylenchida), Pristionchus sp. (Rhabditida) and Prodorylaimus sp. (Dorylaimida) when their specimens were difficult to amplify with the one primer set and DreamTaq™ (data not shown). This improvement provides high fidelity, sensitivity and yield with minimum optimization of reaction and cycling conditions. It should not be limited to long segment PCR amplification only, and could be considered for short range PCR with forensic or ancient DNA, single copy nuclear gene PCR or where improved proofreading can rescue mismatches that take place between the 3’ primer termini and its target templates.

eISSN:
2640-396X
Język:
Angielski
Częstotliwość wydawania:
Volume Open
Dziedziny czasopisma:
Life Sciences, other