Compatibility testing problems associated with bovine thrombin–treated plasma
, , , oraz
12 cze 2018
O artykule
Data publikacji: 12 cze 2018
Zakres stron: 19 - 21
DOI: https://doi.org/10.21307/immunohematology-2019-951
Słowa kluczowe
© 1993 R.S. SHIREY, et al., published by Sciendo
Plasma converted to serum by the addition of bovine thrombin prior to compatibility testing agglutinated all donor red cells. This finding prompted an investigation of bovine thrombin–associated incompatibility that showed that (1) thrombin derived from bovine plasma contains IgG antibodies directed against all human red cells, and (2) excess (> 50 units/mL) bovine thrombin used for conversion of plasma to serum may cause hemagglutination and erroneous serologic test results because of the presence of heteroagglutinins.