Performance evaluation of a rectifier column using gamma column scanning
Data publikacji: 16 lut 2018
Zakres stron: 285 - 287
Otrzymano: 28 mar 2017
Przyjęty: 04 gru 2017
DOI: https://doi.org/10.1515/nuka-2017-0041
Słowa kluczowe
© 2017 Denis D. Aquino et al., published by De Gruyter Open
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License.
Rectifier columns are considered to be a critical component in petroleum refineries and petrochemical processing installations as they are able to affect the overall performance of these facilities. It is deemed necessary to monitor the operational conditions of such vessels to optimize processes and prevent anomalies which could pose undesired consequences on product quality that might lead to huge financial losses. A rectifier column was subjected to gamma scanning using a 10-mCi Co-60 source and a 2-inch-long detector in tandem. Several scans were performed to gather information on the operating conditions of the column under different sets of operating parameters. The scan profiles revealed unexpected decreases in the radiation intensity at vapour levels between trays 2 and 3, and between trays 4 and 5. Flooding also occurred during several scans which could be attributed to parametric settings.