[1. Polgár, C., Van Limbergen, E., Pötter, R., Kovács, G., Polo, A., Lyczek, J., Hildebrandt, G., Niehoff, P., Guinot, J. L., Guedea, F., Johansson, B., Ott, O. J., Major, T., & Strnad, V. (2010). Patient selection for accelerated partial-breast irradiation (APBI) after breast-conserving surgery: recommendations of the Groupe Européen de Curiethérapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) breast cancer working group based on clinical evidence. Radiother. Oncol., 94(3), 264–273. DOI: 10.1016/j.radonc.2010.01.014.10.1016/j.radonc.2010.01.01420181402]Search in Google Scholar
[2. ASTRO Task Force. (2009). Accelerated partial breast irradiation consensus statement from the American Society for Radiation Oncology (ASTRO). Int. J. Radiat. Oncol. Biol. Phys., 74(4), 987–1001. DOI: 10.1016/j.ijrobp.2009.02.031.10.1016/j.ijrobp.2009.02.03119545784]Search in Google Scholar
[3. National Centre for Nuclear Research. (January 2014). Accelerators & detectors. Retrieved September 8, 2014, from http://aid.ncbj.gov.pl/index.php/en.]Search in Google Scholar
[4. Kania, M., & Rostkowska, J. (2001). Krajowe zalecenia dotyczące kontroli aparatów stosowanych w teleradioterapii. Pol. J. Med. Phys. Eng., 7(3), 199–278.]Search in Google Scholar
[5. European Committee for Electrotechnical Standardization. (2009). European Standard: Medical electrical equipment. Part 2-1: Particular requirements for the safety of electron accelerators in the range of 1 MeV to 50 MeV. IEC 60601-2-1 Ed. 3.0. Brussels.]Search in Google Scholar
[6. Adrich, P., Baczewski, A., Baran, M., Drabik, W., Gryn, K., Hanke, R., Jakubowska, E., Jankowski, E., Kędzierski, G., Kielar, N., Kujawski, Ł., Kopeć, J., Kosiński, K., Kozioł, R., Kraszewski, P., Krawczyk, P., Kulczycka, E., Lalik, P., Marczenko, M., Masternak, A., Misiarz, A., Olszewski, J., Ozon, K., Pławski, E., Polak, A., Psonka, W., Rutkowska, M., Rzadkiewicz, J., Sienkiewicz, Z., Staszczak, M., Swat, K., Syntfeld-Każuch, A., Terka, M., Wasilewski, A., Wilczek, J., Wojciechowski, M., Wójtowicz, M., Wronka, S., Wysocka-Rabin, A., & Zalewski, K. (2014). A new mobile electron accelerator for intra operative electron radiation therapy. Int. J. Mod. Phys. Conf. Ser., 27, 1460125. DOI: 10.1142/S2010194514601252.10.1142/S2010194514601252]Search in Google Scholar
[7. Wysocka-Rabin, A., Adrich, P., & Wasilewski, A. (2014). Radiation protection studies for a new mobile electron accelerator for intra operative radiation therapy (IORT). Prog. Nucl. Sci. Technol., 4, 298–302.10.15669/pnst.4.298]Search in Google Scholar
[8. Wysocka-Rabin, A., Adrich, P., & Wasilewski, A. (2011). Monte Carlo study of a new mobile electron accelerator head for intra operative radiation therapy (IORT). Prog. Nucl. Sci. Technol., 2, 181–186.10.15669/pnst.2.181]Search in Google Scholar