Introduction

Porcine circovirus (PCV) is a circular single-stranded negative-strand DNA non-enveloped virus that belongs to the Circoviridae family and the Circovirus genus (7). Currently, four different porcine circoviruses have been reported: PCV1 (16), PCV2 (8), PCV3 (10) and PCV4 (20). The first of the viruses was discovered in 1974 as a contaminant of a porcine kidney cell line (PK-15) and is considered non-pathogenic (15). On the other hand, PCV2 is recognised as a necessary but insufficient agent of porcine-circovirus-associated diseases (PCVAD), including postweaning multisystemic wasting syndrome (PMWS) and porcine dermatitis and nephropathy syndrome (PDNS) (5, 12, 17). PCV2 has become a threat to the swine industry globally. In 2016, a new porcine circovirus was detected from the tissue homogenate of sows exhibiting similar symptoms to PDNS and inflammation of the heart and multiple organs, and the virus, designated PCV3, was identified to be another potential pathogenic factor of clinical diseases in pigs (10, 11).

In April 2019 in Hunan Province, China, Zhang et al. (20) discovered a new type of PCV in pigs with severe clinical diseases, including respiratory diseases, diarrhoea, porcine dermatitis and nephrotic syndrome; this type, PCV4, poses a threat to the pig industry. The genome of PCV4 has a total length of 1,770 nucleotides (nt). Based on prediction using ORFfinder (https://www.ncbi.nlm.nih.gov/orffinder/), PCV4 contains 12 open reading frames (ORF) with two major predicted genes: a replicase gene spanning 891 nt encoding a protein of 296 amino acids, and a capsid gene spanning 687 nt encoding a protein of 228 amino acids (20). There were no relevant reports of PCV4 detection in other regions, and therefore an efficient, sensitive and rapid detection method is needed to provide specific diagnosis that may facilitate accurate clinical investigation in minimal time during the PCV4 epidemic.

Material and Methods

Viruses and clinical samples. All viruses used in this study were collected in our laboratories, including porcine reproductive and respiratory syndrome virus (PRRSV) strains, porcine epidemic diarrhoea virus (PEDV), classical swine fever virus (CSFV) attenuated vaccine, porcine parvovirus (PPV) and pseudorabies virus (PRV). A total of 67 samples (55 blood samples, 2 tissue samples, 9 saliva swabs and 1 semen sample) were investigated, which were submitted to the Department of Veterinary Medicine, Sichuan Agricultural University from 15 pig farms located in the cities of Chengdu, Mianyang, Suining, Dazhou, Zigong, Dazhou, Nanchong, and Guangyuan of the Sichuan province of China between 2018 and 2021.

Construction of the PCV4 whole genome plasmid. The whole genome of PCV4 (1,770 bp) was synthesised artificially (Sangon Biotech, Shanghai, China) based on a reference sequence of a Chinese isolate available in GenBank (accession no. MT311852.1), and then cloned into pUC57 Vector (TIANGEN, Beijing, China). The plasmid DNA construct of pUC57-PCV4 was amplified in E. coli DH5α and subsequently purified using a Plasmid MiniPrep Kit (Sangon Biotech) and quantified using a NanoDrop 2000 spectrophotometer (Thermo Fisher, Waltham, MA, USA).

Primers and probe for PCV4. Forward and reverse PCV4 primers and a PCV4 probe were designed manually based on the conserved regions shown by the alignment of the ORF2 gene from complete genome sequences of the PCV4 reference sequence isolated in China. The nucleotide sequences of the primers and the probe are listed in Table 1.

DNA cloning and sequencing. The plasmid constructed in the previous step was used as the template for DNA amplification using the PCV4-F/R primer set. The amplified target fragment was recovered and then cloned into pMD-19T Vector (TaKaRa, Dalian, China) for DH5α (TIANGEN) transformation. Following colony screening and identification, positive clones containing the desired DNA insert were grown overnight in a culture volume of 5 mL for plasmid isolation using a Plasmid MiniPrep Kit (Sangon Biotech). The DNA concentration of the plasmid construct pMD19T-PCV4 was quantified using the NanoDrop 2000 spectrophotometer (Thermo Scientific). The number of plasmid DNA copies was calculated using the following formula: amount (copies/μL) = (DNA concentration (g/μL)/(plasmid length in base pairs × 660) × 6.02 ×1023.

Optimisation of the real-time PCR. A real-time PCR was performed on the CFX Connect Real-Time PCR Detection System (Bio-Rad, Hercules, CA, USA) in a reaction volume of 25 μL containing 12.5 μL of SsoAdvanced Universal Probe Supermix (Bio-Rad), different volumes of each primer (10 μmol/L) and probe (10 μmol/L), 2 μL of DNA template and RNase-free deionised distilled water (ddH2O). The qPCR conditions were as follows: initial denaturation at 94°C for 2 min followed by 40 cycles at 94°C for 10 s and final extension at 55.4°C for 30 s.

Method standardisation. The DNA concentration of the pMD19T-PCV4 plasmid construct was determined using the NanoDrop2000 spectrophotometer (Thermo Scientific) before being serially diluted ten-fold. Each diluted concentration in the range from 2.20 × 108 copies/μL to 2.20 × 103 copies/μL was tested by qPCR in triplicate. The calibration curves were generated by CFX Manager software (Bio-Rad). The standard curve of Ct versus plasmid copies was then constructed.

Specificity analysis. For specificity analysis, 10 ng of viral DNA or cDNA from PCV2, PCV3, PPV, PRV, PRRSV, PEDV, FMDV vaccine and CSFV vaccine (all provided by the Sichuan Agricultural University) was used as templates for amplification by real-time PCR. The analysis also used pMD19T-PCV4 plasmid construct as the positive control and ddH2O as the negative control. To evaluate the specificity of this method, the real-time TaqMan PCR assay established in this study was used for amplification.

Sensitivity analysis. Plasmid DNA of pMD19-PCV4 with a concentration ranging from 108 to 101 copies/μL was used to evaluate the sensitivity of the real-time PCR. The best reaction conditions with the minimum detection volume in the PCR assay developed in the course of this investigation were used for sensitivity evaluation.

Nucleotide sequences of PCV4 primers and PCV4 probe

Primer Nucleotide sequence (5ʹ–3ʹ) Nt position
PCV4-F AATCTCACTGTCCACACCTG 1105–1124
PCV4-R CAAAACCCCAGGACCCATC 1267–1249
PCV4-probe FAM-ACCCACACCCTCCACTTCCAGC-BHQ1

PCV4 – porcine circovirus 4

Repeatability and reproducibility analyses. To determine the reproducibility and repeatability of the real-time PCR, 105, 104, 103 and 102 copies of pMD19-PCV4 were tested in triplicate in three independent experiments. The inter-assay variability was evaluated in three independent runs and in different thermocyclers (ABI, Forster, CA, USA; Roche Diagnostics, Risch-Rotkreuz, Switzerland; Bio-Rad) performed on different days. The mean, standard deviation and coefficient of variation (CV) were calculated using the Ct values obtained for each dilution in each run. The range (minimum and maximum values) for each parameter was determined. The mean, standard deviation and the CV were calculated using SPSS statistical software (IBM, Armonk, NY, USA) to evaluate the method repeatability.

Detection of PCV4 from clinical samples. Viral DNA was extracted from 72 clinical samples, which were amplified using the developed real-time PCR method. Samples amplified before 38 cycles with typical amplification curves were considered PCV4-positive. Evaluation was repeated if a typical amplification curve was observed with a Ct value of greater than 38. Samples that underwent repeated tests with the same result were considered positive, and those showing inconsistent results in repeated tests were considered negative.

Results

Real-time PCR optimisation. Reactions containing 12.5 μL of SsoAdvanced Universal Probe Supermix (Bio-Rad), 8.05 μL of RNase-free ddH2O, 2 μL of DNA template, 1.1 μL of each primer (10 μmol/L) and 0.25 μL of solution of probe (10 μmol/L) were found to produce the strongest fluorescent signals.

Using the pUC57-PCV4 construct as the template, the target fragment with a length of 163 bp was successfully amplified by PCR with specific primers. Following DNA purification, the PCR products were cloned into the pMD19-T Vector to construct a pMD19T-PCV4 recombinant plasmid standard. Comparison of the DNA sequencing results for the isolates from the samples with the reference sequence revealed no mutation in the sequence of the DNA insert, showing that the pMD19T-PCV4 recombinant plasmid standard had been successfully constructed. DNA quantification showed that the plasmid concentration was 2.20 × 109 copies/μL.

Standard curve. For standard curve generation, pMD19T-PCV4 was diluted tenfold in RNase-free ddH2O, and the diluted samples were used as the template for the real-time PCR. As shown in Fig. 1, the generated standard curve had a range of 103–108 copies/μL with a good linear correlation between 2.20 × 108 copies/μL and 2.20 × 103 copies/μL (Slope: −3.330; y-int: 34.697; correlation coefficient R2: 1.000; amplification efficiency: 99.6%).

Fig. 1

Standard curve of PCV4 real-time PCR for serially diluted pMD19T-PCV4 recombinant plasmids. Mean threshold cycle (Ct) values from three replicates (y-axis) are plotted versus logarithmic concentrations of plasmid copies (x-axis)

Specificity analysis. Using DNA and cDNA of other viruses or vaccines as templates, our results showed that only PCV4 was detected by real-time PCR, while other viruses were undetected. Similar results were obtained from three repeated independent reactions, demonstrating that the assay was highly specific.

Sensitivity analysis. To evaluate the assay sensitivity, diluted pMD19T-PCV4 samples with a concentration range of 108–101 copies/μL were used as a template. Our results showed that the real-time PCR had a detection limit of 101 copies and similar results were obtained from three repeated independent reactions (Fig. 2).

Fig. 2

Sensitivity analysis of the TaqMan real-time PCR for PCV4. RFU – relative fluorescence units; 1–8 – 2.2 × 108 copies/μL–2.2 × 101 copies/μL. The lowest copy number detected by qPCR was 2.2 × 101 copies/μL

Reproducibility analysis. In order to evaluate the repeatability of the detection method, the assay was carried out using recombinant plasmids at three different concentrations from 2.20 × 105 to 2.20 × 102 copies/μL. Each concentration was evaluated three times, and the determined Ct values, mean, standard deviation and CV are shown in Table 2. Our results showed that the experimentally established method for the detection of PCV4 genotype by fluorescence quantitative PCR has good reproducibility. Therefore, this method can be used for stable and reliable detection of the PCV4 genotype from the samples.

Repeatability test of qPCR

Positive plasmid concentration Intra-assay Inter-assay
(copies/μL) Ct (mean ± SD) CV % Ct (mean ± SD) CV %
2.20 × 105 18.15 ± 0.22 1.21 18.14 ± 0.25 1.38
2.20 × 104 21.48 ± 0.14 0.65 21.49 ± 0.18 0.84
2.20 × 103 24.98 ± 0.16 0.64 24.92 ± 0.28 1.12
2.20 × 102 28.56 ± 0.36 1.26 28.53 ± 0.48 1.68

Ct – threshold cycle

Detection of PCV4 in clinical samples. Using 67 samples collected from pig farms in different regions of the Sichuan province from 2018 to 2021, the practicability of the established quantitative PCR (qPCR) detection method based on TaqMan was evaluated. A positive rate of 4% (3/67) was determined by qPCR, all samples positive by qPCR were sequenced. The similarity between MT311852.1 and the four isolates ranged from 95.45% to 98.85%.

Discussion

The four PCVs are similar in structure with two ORFs oriented in opposite directions in the circular genome; ORF1 or the rep genes Rep and Repʹ encoding proteins associated with replication (not characterised for PCV3 or PCV4 at this point); and ORF2 or the cap gene encoding the capsid or Cap protein (1). The fourth type of the virus was first identified in 7- and 12-week-old pigs suffering from respiratory, enteric and PDNS symptoms, and also in healthy pigs in April 2019 (20). Since the discovery of PCV4, only a few sequences of the virus have become available and the clinical significance and pathogenic mechanism of the virus have not been reported. An efficient and stable detection method is an effective means to control and prevent the spread of the newly emerging virus.

Currently, real-time fluorescent PCR is widely used in clinical detection. Compared with loop-mediated isothermal amplification, the TaqMan-based real-time PCR assay has superior accuracy. Isothermal amplification requires specialised personnel for operation, and the samples are vulnerable to contamination; therefore, the potential for false positive results is high and it is difficult to guarantee the accuracy of detection (18). Compared with SYBR, the cost of TaqMan assays is higher, where the expense probe synthesis particularly is a consideration. Another of their disadvantages is that quantification is often affected by enzyme performance because of the use of the 5ʹ→3ʹ exonuclease activity of the Taq enzyme. However, the advantage of real-time TaqMan PCR over SYBR-Green-based PCR (19) is that it yields highly specific, low false positives and read-through signals generated by the TaqMan probe. Compared with conventional PCR (14), real-time PCR is able to detect the reaction process in real time and determine the absolute amount of amplified products, with strong specificity and better sensitivity. The developed real-time PCR assay is rapid with no requirement for post-PCR steps. Real-time TaqMan PCR and ELISA are the most commonly used laboratory confirmation methods for the early diagnosis of the virus, but the targets detected by the two methods are different. Viral antibody detection is an indirect method of confirming viral infections, so the clinical significance is slightly different. In viral infections, viraemia occurs first, and then the antibodies are produced. The real-time TaqMan PCR method can detect positive specimens ≤1 d after the onset, while the ELISA method can detect positive samples only a few days after (4).

At present, according to research reports, PCV4 has been detected in Hunan, Guangxi, Shaanxi, Henan and Inner Mongolia provinces of China (3, 6, 13, 14, 20). This is the first study to report the successful detection of PCV4 in the Sichuan province. The virus was also successfully detected in South Korea in 2021 (9). Evidence is lacking of this virus’ presence outside Asia: PCV4 has not been detected in Italy or Spain (2). It may be due to trade in pork products between these two countries and China not taking place frequently. However, PCV4 may eventually circulate globally because of international trade.

In conclusion, we successfully developed and evaluated a real-time PCR assay for rapid and accurate detection of PCV4. Our established real-time PCR method detected down to a lower limit of 101 copies, and it was analytically specific and sensitive with low intra- and inter-assay CV (<1.67 %), indicating reproducible and reliable in providing rapid and accurate PCV4 detection.