Accesso libero

Shielding effectiveness of textile woven fabric with conductive weft in microwave frequency range

INFORMAZIONI SU QUESTO ARTICOLO

Cita

Fig.1.

Coaxial probe for shielding effectiveness measurement: a - electric field and magnetic field in coaxial transmission line, b – material sample alignment
Coaxial probe for shielding effectiveness measurement: a - electric field and magnetic field in coaxial transmission line, b – material sample alignment

Fig.2.

Schematic of measurement setup
Schematic of measurement setup

Fig.3.

Picture of measurement setup with sample holder and microwave absorbers (antenna distance D not to scale)
Picture of measurement setup with sample holder and microwave absorbers (antenna distance D not to scale)

Fig.4.

Shielding effectiveness for different rotation angles
Shielding effectiveness for different rotation angles

Shielding effectiveness of samples measured for an electric field parallel to the conducting fibres, j =0°

Sample Shielding effectiveness at 8.5 GHz [dB] Shielding effectiveness at 12 GHz [dB]
1. Steel + CNT +Graphene 23 16
2. Steel + CNT + Ag 24 17.5
3. Steel + CNT 25 17
4. Steel 27 19