Login
Registrati
Reimposta password
Pubblica & Distribuisci
Soluzioni Editoriali
Soluzioni di Distribuzione
Temi
Architettura e design
Arti
Business e Economia
Chimica
Chimica industriale
Farmacia
Filosofia
Fisica
Geoscienze
Ingegneria
Interesse generale
Legge
Letteratura
Linguistica e semiotica
Matematica
Medicina
Musica
Scienze bibliotecarie e dell'informazione, studi library
Scienze dei materiali
Scienze della vita
Scienze informatiche
Scienze sociali
Sport e tempo libero
Storia
Studi classici e del Vicino Oriente antico
Studi culturali
Studi ebraici
Teologia e religione
Pubblicazioni
Riviste
Libri
Atti
Editori
Blog
Contatti
Cerca
EUR
USD
GBP
Italiano
English
Deutsch
Polski
Español
Français
Italiano
Carrello
Home
Riviste
Applied Mathematics and Nonlinear Sciences
Volume 8 (2023): Numero 1 (January 2023)
Accesso libero
Influence of displacement ventilation on the distribution of pollutant concentrations in livestock housing
Zhang Ruifeng
Zhang Ruifeng
,
Wang Hao
Wang Hao
e
Xu Zhenjun
Xu Zhenjun
| 29 apr 2022
Applied Mathematics and Nonlinear Sciences
Volume 8 (2023): Numero 1 (January 2023)
INFORMAZIONI SU QUESTO ARTICOLO
Articolo precedente
Articolo Successivo
Sommario
Immagini e tabelle
Bibliografia
Autori
Articoli in questo Numero
Anteprima
PDF
Cita
CONDIVIDI
Pubblicato online:
29 apr 2022
Pagine:
2281 - 2290
Ricevuto:
05 gen 2022
Accettato:
23 feb 2022
DOI:
https://doi.org/10.2478/amns.2021.2.00181
Parole chiave
displacement ventilation
,
number of air changes
,
pollutant concentration
,
ventilation volume
,
emission rate
© 2023 Zhang Ruifeng et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Fig. 1
Physical model and distribution of measurement points
Fig. 2
Variation of CO concentration values under different operating mode at one measurement site
Fig. 3
Variation of CO concentration values under different operating mode at measurement point 2
Fig. 4
Variation of CO concentration values at the three measurement points under different operating modes
Fig. 5
Variation of CO concentration values at four measurement points under different operating modes
Fig. 6
Variation of CO concentration values at five measurement points under different operating modes
Fig. 7
Variation of CO concentration values at the six measurement points under different operating modes
Fig. 8
Variation of CO concentration values at seven measurement points under different operating modes
Fig. 9
Airflow rate distribution in the room for operating mode 1
Fig. 10
Airflow rate distribution in the room for operating mode 2
Fig. 11
Airflow rate distribution in the room for operating mode 3
Fig. 12
Airflow rate distribution in the room for operating mode 4
Fig. 13
Airflow rate distribution in the room for operating mode 5
Fig. 14
Vector diagram of the airflow velocity in the room for operating mode 1
Fig. 15
Vector diagram of the airflow velocity in the room for operating mode 2
Fig. 16
Vector diagram of airflow velocities in the room for operating mode 3
Fig. 17
Vector diagram of airflow velocity in the room for operating mode 4
Fig. 18
Vector diagram of airflow velocities in the room for operating mode 5