Login
Registrati
Reimposta password
Pubblica & Distribuisci
Soluzioni Editoriali
Soluzioni di Distribuzione
Temi
Architettura e design
Arti
Business e Economia
Chimica
Chimica industriale
Farmacia
Filosofia
Fisica
Geoscienze
Ingegneria
Interesse generale
Legge
Letteratura
Linguistica e semiotica
Matematica
Medicina
Musica
Scienze bibliotecarie e dell'informazione, studi library
Scienze dei materiali
Scienze della vita
Scienze informatiche
Scienze sociali
Sport e tempo libero
Storia
Studi classici e del Vicino Oriente antico
Studi culturali
Studi ebraici
Teologia e religione
Pubblicazioni
Riviste
Libri
Atti
Editori
Blog
Contatti
Cerca
EUR
USD
GBP
Italiano
English
Deutsch
Polski
Español
Français
Italiano
Carrello
Home
Riviste
Architecture, Civil Engineering, Environment
Volume 16 (2023): Numero 4 (December 2023)
Accesso libero
Reliable Tilt of Objects Subjected to Rectification and Located in Mining Areas
Krzysztof Gromysz
Krzysztof Gromysz
| 31 dic 2023
Architecture, Civil Engineering, Environment
Volume 16 (2023): Numero 4 (December 2023)
INFORMAZIONI SU QUESTO ARTICOLO
Articolo precedente
Articolo Successivo
Sommario
Articolo
Immagini e tabelle
Bibliografia
Autori
Articoli in questo Numero
Anteprima
PDF
Cita
CONDIVIDI
Pubblicato online:
31 dic 2023
Pagine:
79 - 92
Ricevuto:
28 apr 2023
Accettato:
08 giu 2023
DOI:
https://doi.org/10.2478/acee-2023-0052
Parole chiave
Vertical deflection of a building
,
Rectification
,
Non-uniform elevation
,
Slope of mining area
,
Non-uniform depression of mining area
© 2023 Krzysztof Gromysz, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Figure 1.
A single-storey building of a church: a) plan, b) section view, c) building during rectification, d) view of east side after rectification; based on [19]
Figure 2.
Plan and cross-section of a single-storey building with a usable attic and a garage, 1 – axis of rotation, 2 – “zero” point, 3 – tearing plane
Figure 3.
Rectified building with a usable attic and a garage: a) view of the southern side, b) western wall
Figure 4.
Two-storey building, 1 – the level of building tearing
Figure 5.
North-western corner of the two-storey building: a) prior to rectification, b) during rectification, c) after rectification with noticeable displacement uobj = 1312 mm
Figure 6.
11-storey building: a) ground floor plan, b) northern elevation; 1 – axis of rotation, 2 – fixed point, 3 – incision plane
Figure 7.
11-storey building during rectification: a) jacks installed in the wall, b) strengthening of the elevator shaft, whose deflection was regarded as reliable
Figure 8.
A complex of buildings connected functionally with a patio
Figure 9.
Rectified complex of buildings: a) view from the southeastern side, b) temporary supports during rectification
Figure 10.
Rectified historic timber building of museum: a) ground floor plan with determined values uobj, b) cross-section, c) works related to the new foundation; based on [20]
Figure 11.
Rectified bell tower: a) vertical section, b) floor plan with determined values uobj, c) reinforced concrete ring beam supported on piles, based on [21]
Figure 12.
Tower during works of a) rectification, b) replacement of roof sheathing
Figure 13.