Air supply | 0 Pa |
---|---|
first fan speed | 9 m3/h |
second fan speed | 16 m3/h |
third fan speed | 28 m3/h |
Air exhaust | 0 Pa |
first fan speed | 8 m3/h |
second fan speed | 14 m3/h |
third fan speed | 29 m3/h |
Working conditions | Supply efficiency |
---|---|
third fan speed at balanced pressures | 64% |
second fan speed at balanced pressures | 68% |
first fan speed at balanced pressures | 79% |
third fan speed at a natural pressure difference | 56% |
second fan speed at a natural pressure difference | 47% |
Working conditions | Exhaust efficiency |
---|---|
third fan speed at balanced pressures | 73% |
second fan speed at balanced pressures | 83% |
first fan speed at balanced pressures | 85% |
third fan speed at a natural pressure difference | 79% |
second fan speed at a natural pressure difference | 93% |
Air supply | 7 Pa |
---|---|
first fan speed | 19 m3/h |
second fan speed | 22 m3/h |
third fan speed | 36 m3/h |
Air exhaust | 7 Pa |
first fan speed | -8 m3/h |
second fan speed | 6 m3/h |
third fan speed | 25 m3/h |
Air supply | 4 Pa |
---|---|
first fan speed | 14 m3/h |
second fan speed | 20 m3/h |
third fan speed | 32 m3/h |
Air exhaust | 4 Pa |
first fan speed | 2 m3/h |
second fan speed | 12 m3/h |
third fan speed | 27 m3/h |