Accès libre

FEM Approach to Estimate the Behaviour of Biocomposite Metal-Surface Coating Systems

À propos de cet article

Citez

A three dimensional (3D) model of biocomposite metal-surface coating system, which is influenced by known external forces, is proposed. This model consists of the metallic substrate (Ti6A14V) and the hydroxyapatite (HA) coating. Using FEM (finite element method), strain-stress maps of model were generated for investigating relations between the extreme stress of HA coating and the magnitude of external force and the thickness of the coating. The analysis of numerical simulations results confirms that the system with the greatest coating thickness (i.e. 10-3 m) has the least extreme stress in this surface coating.

eISSN:
2083-4799
ISSN:
1730-2439
Langue:
Anglais
Périodicité:
4 fois par an
Sujets de la revue:
Materials Sciences, Functional and Smart Materials