Seismic bearing capacity of shallow strip footing embedded in slope resting on two-layered soil
30 sept. 2021
À propos de cet article
Catégorie d'article: Original Study
Publié en ligne: 30 sept. 2021
Pages: 285 - 306
Reçu: 15 déc. 2020
Accepté: 20 juin 2021
DOI: https://doi.org/10.2478/sgem-2021-0021
Mots clés
© 2021 Litan Debnath, published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
In this paper, the limit equilibrium method with the pseudo-static approach is developed in the evaluation of the influence of slope on the bearing capacity of a shallow foundation. Particle swarm optimisation (PSO) technique is applied to optimise the solution. Minimum bearing capacity coefficients of shallow foundation near slopes are presented in the form of a design table for practical use in geotechnical engineering. It has been shown that the seismic bearing capacity coefficients reduce considerably with an increase in seismic coefficient. Be sides, the magnitude of bearing capacity coefficients decreases further with an increase in slope inclination.