[1. CAROSIO, F., CUTTICA, F., MEDINA, L., BERGLUND, L., A. 2016. Clay nanopaper as multifunctional brick and mortar fire protection coating-Wood case study. In: Materials and Design, 93(1), pp. 357-363.]Search in Google Scholar
[2. CARVEL, R., STEINHAUS, T., REIN, G., TORERO, J., L. 2011. Determination of the flammability properties of polymeric materials: a novel method. In: Polymer Degradation and Stability, 96(3), pp. 314-319.]Search in Google Scholar
[3. EN 13501-6:2018. Fire classification of construction products and building elements. Part 6: Classification using data from reaction to fire tests on electric cables.]Search in Google Scholar
[4. EN 50399:2011. Common test methods for cables under fire conditions. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results.]Search in Google Scholar
[5. EN 50267-2-3:1998. Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables. Part 2-3: Procedures. Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity.]Search in Google Scholar
[6. EN 60332-1-2:2004. Tests on electric and optical fibre cables under fire conditions. Part 1-2: Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame.]Search in Google Scholar
[7. EN 60754-2:2014. Fire Test on gases evolved during combustion of materials from cables. Part 2: Determination of acidity (by pH measurement) and conductivity.]Search in Google Scholar
[8. EN 61034-2:2005. Measurement of smoke density of cables burning under defined conditions. Part 2: Test procedure and requirements.]Search in Google Scholar
[9. EN ISO 1716:2018. Reaction to fire tests for products. Determination of the gross heat of combustion (calorific value).]Search in Google Scholar
[10. GUNTHER, B., GEBAUER, K., BARKOWSKI, R., ROSENTHAL, M., BUES, C., T. 2012. Calorific value of selected wood species and wood products. In: European Journal of Wood and Wood Products, 70(5), pp. 755-757.]Search in Google Scholar
[11. ISO 5660-1:201 Reaction to fire tests. Heat release, smoke production and mass loss rate. Part 1: Heat release rate (cone calorimeter method) and smoke production rate (dynamic measurement).]Search in Google Scholar
[12. Martinka 2016]Search in Google Scholar
[13. MARTINKA, J., MARTINKA, F., RANTUCH, P., HRUŠOVSKÝ, I., BLINOVÁ, L., BALOG, K. 2018. Calorific value and fire risk of selected fast-growing wood species. In: Journal of Thermal Analysis and Calorimetry, 131(2), pp. 899-906.]Search in Google Scholar
[14. MARTINKA, J., RANTUCH, P., BALOG, K. 2017. Fire hazard and heat of combustion of sunflower seed hull pellets. In: Journal of Thermal Analysis and Calorimetry, 130(3), pp. 1531-1540.]Search in Google Scholar
[15. MITTEROVA, I., ZACHAR, M., RUZINSKA, E., MAJLINGOVA, A. 2004. Ignitability of unprotected and retardant protected samples of spruce wood. In: Advanced Materials Research, 1001(1), pp. 330-335.]Search in Google Scholar
[16. OSTMAN, B., A., L. 2009. Smoke and soot. In: Babrauskas, V., Grayson, S., J., editors. Heat release in fires. 2nd ed. Hampshire: Interscience communications, pp. 233-250.]Search in Google Scholar
[17. SCHARTEL, B., BARTHOLMAI, M., KNOLL, U. 2005. Some comments on the use of cone calorimeter data. In: Polymer Degradation and Stability, 88(3), pp. 540-547.]Search in Google Scholar
[18. STN 92 0203:2013 Fire protection of buildings. Continuous power supply responding for fire.]Search in Google Scholar
[19. WITKOWSKI, A., HOLLINGBERRY, L., HULL, R., T. 2012. Fire retardancy of mineral fillers in EVA copolymers. In: Morgan, A., B., Wilkie, C., A., Nelson, G., L., editors. ACS symposium series 1118, fire and polymers VI: new advances in flame retardant chemistry & science. Washington: American Chemical Society, pp. 97-111.]Search in Google Scholar
[20. ZHANG, J. 2008. Study of polyamide 6-based nanocomposites. New York: Polytechnic University.]Search in Google Scholar