New Approaches to Comprehensive Electrochemical Processing of Sulfate-Chloride High-Mineralized Wastewater Treatment Residues
20 oct. 2023
À propos de cet article
Publié en ligne: 20 oct. 2023
Pages: 171 - 180
Reçu: 25 avr. 2023
Accepté: 19 juin 2023
DOI: https://doi.org/10.2478/acee-2023-0044
Mots clés
© 2023 Tetyana Shabliy et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Dependence of acidity (alkalinity) of anodic, cathodic, and working solutions on the time of electrolysis of sodium sulfate solution (C=32 g/dm3), current density, and type of electrolyzer
Electrolysis time, t, hours | Number of chambers | I, A/dm2 | Membrane | Cathode zone | Anode zone | Working zone, concentration (C), mg-eq/dm3 | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Cationic | Anionic | Acidity, mg-eq/dm3 | B, % | Alkalinity, mg-eq/dm3 | B, % | |||||||
I | II | I | II | I | II | |||||||
3.5 | 3 | 3.97 | MC-40 | MA-41 | 1 | 437 | 55.6 | 1 | 426 | 54.2 | - | 4 |
4.0 | 3 | 3.97 | 437 | 828 | 43.6 | 426 | 715 | 32.4 | 4 | 0 | ||
3.5 | 3 | 3.97 | 828 | 1096 | 34.2 | 715 | 987 | 34.7 | 0 | 2 | ||
4.5 | 3 | 3.97 | 1096 | 1448 | 34.9 | 987 | 1301 | 31.2 | 2 | 0 | ||
4.0 | 3 | 3.97 | 1448 | 1751 | 33.8 | 1301 | 1571 | 30.1 | 0 | 6 | ||
5.0 |
3 | 6.62 | 9 | 1012 | 53.6 | 1 | 824 | 44.1 | 0 | 586 | ||
6.0 | 2 | 3.97 | - | 9 | 346 | 25.7 | 1 | 468 | 34.7 | - | - | |
7.0 | 2 | 3.97 | MC-40 | - | 9 | 400 | 24.9 | 1 | 446 | 28.4 | - | - |