Temporal distribution of linear densities of the plasma column in a plasma focus discharge
, , , , , , , et
22 juin 2015
À propos de cet article
Publié en ligne: 22 juin 2015
Pages: 315 - 318
Reçu: 08 juin 2014
Accepté: 18 févr. 2015
DOI: https://doi.org/10.1515/nuka-2015-0065
Mots clés
© Balzhima Cikhardtova et al.
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Experiments were carried out on the PF-1000 plasma focus device, with a deuterium filling and with deuterium puffing from a gas-puff nozzle placed on the axis of the anode face. The current was reaching 2 MA. 15 interferometric frames from one shot were recorded with a Nd:YLF laser and a Mach–Zehnder interferometer, with 10–20 ns delay between the frames. As a result, the temporal and spatial distribution of the linear densities and the radial and axial velocities of the moving of plasma in the dense plasma column could be estimated.