Acceso abierto

Prototype analysis of a low-power, small-scale wearable medical device

 y   
04 ene 2025

Cite
Descargar portada

Miao F, Wu D, Liu Z, Zhang R, Tang M and Li Y. Wearable sensing, big data technology for cardiovascular healthcare: current status and future prospective. Chinese Medical Journal 2023; vol. 136. Publisher: Chinese Medical Journals Publishing House Co., Ltd. 42 Dongsi Xidajie:1015–25. DOI: 10.1097/CM9.0000000000002117 Miao F Wu D Liu Z Zhang R Tang M Li Y. Wearable sensing, big data technology for cardiovascular healthcare: current status and future prospective . Chinese Medical Journal 2023 ; vol. 136 . Publisher: Chinese Medical Journals Publishing House Co., Ltd. 42 Dongsi Xidajie : 1015 25 . DOI: 10.1097/CM9.0000000000002117 Open DOISearch in Google Scholar

Mizuno A, Changolkar S and Patel MS. Wearable devices to monitor and reduce the risk of cardiovascular disease: evidence and opportunities. Annual review of medicine 2021; vol. 72. Publisher: Annual Reviews:459–71. DOI: 10.1146/annurev-med-050919-031534 Mizuno A Changolkar S Patel MS. Wearable devices to monitor and reduce the risk of cardiovascular disease: evidence and opportunities . Annual review of medicine 2021 ; vol. 72 . Publisher: Annual Reviews : 459 71 . DOI: 10.1146/annurev-med-050919-031534 Open DOISearch in Google Scholar

Hina A and Saadeh W. Noninvasive blood glucose monitoring systems using near-infrared technology—a review. Sensors 2022; 22:4855. DOI: 10.3390/s22134855 Hina A Saadeh W. Noninvasive blood glucose monitoring systems using near-infrared technology—a review . Sensors 2022 ; 22 : 4855 . DOI: 10.3390/s22134855 Open DOISearch in Google Scholar

Shokrekhodaei M, Cistola DP, Roberts RC and Quinones S. Non-invasive glucose monitoring using optical sensor and machine learning techniques for diabetes applications. IEEE Access 2021; 9:73029–45. DOI: 10.1109/ACCESS.2021.3079182 Shokrekhodaei M Cistola DP Roberts RC Quinones S. Non-invasive glucose monitoring using optical sensor and machine learning techniques for diabetes applications . IEEE Access 2021 ; 9 : 73029 45 . DOI: 10.1109/ACCESS.2021.3079182 Open DOISearch in Google Scholar

Sanai F, Sahid AS, Huvanandana J, Spoa S, Boyle LH, Hribar J, Wang DTY, Kwan B, Colagiuri S, Cox SJ et al. Evaluation of a continuous blood glucose monitor: a novel and non-invasive wearable using bioimpedance technology. Journal of diabetes science and technology 2023; 17:336–44. DOI: 10.1177/19322968211054110 Sanai F Sahid AS Huvanandana J Spoa S Boyle LH Hribar J Wang DTY Kwan B Colagiuri S Cox SJ Evaluation of a continuous blood glucose monitor: a novel and non-invasive wearable using bioimpedance technology . Journal of diabetes science and technology 2023 ; 17 : 336 44 . DOI: 10.1177/19322968211054110 Open DOISearch in Google Scholar

McAuley SA, Dang TT, Horsburgh JC, Bansal A, Ward GM, Aroyan S, Jenkins AJ, MacIsaac RJ, Shah RV and O’Neal DN. Feasibility of an orthogonal redundant sensor incorporating optical plus redundant electrochemical glucose sensing. Journal of Diabetes Science and Technology 2016; 10:679–88. DOI: 10.1177/1932296816629982 McAuley SA Dang TT Horsburgh JC Bansal A Ward GM Aroyan S Jenkins AJ MacIsaac RJ Shah RV O’Neal DN. Feasibility of an orthogonal redundant sensor incorporating optical plus redundant electrochemical glucose sensing . Journal of Diabetes Science and Technology 2016 ; 10 : 679 88 . DOI: 10.1177/1932296816629982 Open DOISearch in Google Scholar

Saúde M da. Ministério da Saúde. Available from: https://www.gov.br/saude/pt-br/assuntos/saude-de-a-a-z/d/diabetes Saúde M da. Ministério da Saúde . Available from: https://www.gov.br/saude/pt-br/assuntos/saude-de-a-a-z/d/diabetes Search in Google Scholar

Hina A and Saadeh W. A 186μW photoplethysmography-based noninvasive glucose sensing SoC. IEEE Sensors Journal 2022; 22:14185–95. DOI: 10.1109/JSEN.2022.3180893 Hina A Saadeh W. A 186μW photoplethysmography-based noninvasive glucose sensing SoC . IEEE Sensors Journal 2022 ; 22 : 14185 95 . DOI: 10.1109/JSEN.2022.3180893 Open DOISearch in Google Scholar

Allegri D, Donida A, Malcovati P and Barrettino D. CMOS-based multifrequency impedance analyzer for biomedical applications. IEEE transactions on biomedical circuits and systems 2018; 12:1301–12. DOI: 10.1109/ISCAS.2018.8351287 Allegri D Donida A Malcovati P Barrettino D. CMOS-based multifrequency impedance analyzer for biomedical applications . IEEE transactions on biomedical circuits and systems 2018 ; 12 : 1301 12 . DOI: 10.1109/ISCAS.2018.8351287 Open DOISearch in Google Scholar

Hesham R, Soltan A and Madian A. Energy harvesting schemes for wearable devices. AEU-International Journal of Electronics and Communications 2021; 138:153888. DOI: 10.1016/j.aeue.2021.153888 Hesham R Soltan A Madian A. Energy harvesting schemes for wearable devices . AEU-International Journal of Electronics and Communications 2021 ; 138 : 153888 . DOI: 10.1016/j.aeue.2021.153888 Open DOISearch in Google Scholar

Corbacho I, Carrillo JM, Ausín JL, Domínguez MÁ, Pérez-Aloe R and Duque-Carrillo JF. Wide-bandwidth electronically programmable CMOS instrumentation amplifier for bioimpedance spectroscopy. IEEE Access 2022; 10. Publisher: IEEE:95604–12. DOI: 10.1109/ACCESS.2022.3204868 Corbacho I Carrillo JM Ausín JL Domínguez Pérez-Aloe R Duque-Carrillo JF. Wide-bandwidth electronically programmable CMOS instrumentation amplifier for bioimpedance spectroscopy . IEEE Access 2022 ; 10 . Publisher: IEEE : 95604 12 . DOI: 10.1109/ACCESS.2022.3204868 Open DOISearch in Google Scholar

Abdolrazzaghi M, Katchinskiy N, Elezzabi AY, Light PE and Daneshmand M. Noninvasive glucose sensing in aqueous solutions using an active split-ring resonator. IEEE Sensors Journal 2021; 21:18742–55. DOI: 10.1109/JSEN.2021.3090050 Abdolrazzaghi M Katchinskiy N Elezzabi AY Light PE Daneshmand M. Noninvasive glucose sensing in aqueous solutions using an active split-ring resonator . IEEE Sensors Journal 2021 ; 21 : 18742 55 . DOI: 10.1109/JSEN.2021.3090050 Open DOISearch in Google Scholar

Constantinou L, Bayford R and Demosthenous A. A wideband low-distortion CMOS current driver for tissue impedance analysis. IEEE Transactions on Circuits and Systems II: Express Briefs 2015; 62:154–8. DOI: 10.1109/TCSII.2014.2387632 Constantinou L Bayford R Demosthenous A. A wideband low-distortion CMOS current driver for tissue impedance analysis . IEEE Transactions on Circuits and Systems II: Express Briefs 2015 ; 62 : 154 8 . DOI: 10.1109/TCSII.2014.2387632 Open DOISearch in Google Scholar

Pedro BG, Marcôndes DWC and Bertemes-Filho P. Analytical model for blood glucose detection using electrical impedance spectroscopy. Sensors 2020; 20:6928 Pedro BG Marcôndes DWC Bertemes-Filho P. Analytical model for blood glucose detection using electrical impedance spectroscopy . Sensors 2020 ; 20 : 6928 Search in Google Scholar

Pedro BG and Bertemes Filho P. Blood Glucose Detection Using 3-LEDs: Analytical Model. Revista Brasileira de Física Médica 2021; 15:613–3. DOI: 10.29384/rbfm.2021.v15.19849001613 Pedro BG Bertemes Filho P. Blood Glucose Detection Using 3-LEDs: Analytical Model . Revista Brasileira de Física Médica 2021 ; 15 : 613 3 . DOI: 10.29384/rbfm.2021.v15.19849001613 Open DOISearch in Google Scholar

Teixeira LG and Bertemes-Filho P. Werable Device For Blood Glucose Level Analysis Using Electrical Bioimpedance and Near-Infrared: Preliminary Results. International Journal of Bioelectromagnetism 2022; 24 Teixeira LG Bertemes-Filho P. Werable Device For Blood Glucose Level Analysis Using Electrical Bioimpedance and Near-Infrared: Preliminary Results . International Journal of Bioelectromagnetism 2022 ; 24 Search in Google Scholar

EGluco. 2024. Available from: https://egluco.bio.br/ EGluco . 2024 . Available from: https://egluco.bio.br/ Search in Google Scholar

Sirtoli V, Morcelles K, Gomez J and Bertemes-Filho P. Design and Evaluation of an Electrical Bioimpedance Device Based on DIBS for Myography during Isotonic Exercises. en. Journal of Low Power Electronics and Applications 2018 Dec; 8. Number: 4 Publisher: Multidisciplinary Digital Publishing Institute:50. DOI: 10.3390/jlpea8040050 Sirtoli V Morcelles K Gomez J Bertemes-Filho P. Design and Evaluation of an Electrical Bioimpedance Device Based on DIBS for Myography during Isotonic Exercises. en . Journal of Low Power Electronics and Applications 2018 Dec ; 8 . Number: 4 Publisher: Multidisciplinary Digital Publishing Institute : 50 . DOI: 10.3390/jlpea8040050 Open DOISearch in Google Scholar

Xu J, Harpe P and Van Hoof C. An Energy-Efficient and Reconfigurable Sensor IC for Bio-Impedance Spectroscopy and ECG Recording. IEEE Journal on Emerging and Selected Topics in Circuits and Systems 2018 Sep; 8. Conference Name: IEEE Journal on Emerging and Selected Topics in Circuits and Systems:616–26. DOI: 10.1109/JETCAS.2018.2834140 Xu J Harpe P Van Hoof C. An Energy-Efficient and Reconfigurable Sensor IC for Bio-Impedance Spectroscopy and ECG Recording. IEEE Journal on Emerging and Selected Topics in Circuits and Systems 2018 Sep ; 8 . Conference Name: IEEE Journal on Emerging and Selected Topics in Circuits and Systems : 616 26 . DOI: 10.1109/JETCAS.2018.2834140 Open DOISearch in Google Scholar

Pliquett U, Schönfeldt M, Barthel A, Frense D, Nacke T and Beckmann D. Front end with offset-free symmetrical current source optimized for time domain impedance spectroscopy. en. Physiological Measurement 2011 Jun. DOI: 10.1088/0967-3334/32/7/S15 Pliquett U Schönfeldt M Barthel A Frense D Nacke T Beckmann D. Front end with offset-free symmetrical current source optimized for time domain impedance spectroscopy. en . Physiological Measurement 2011 Jun . DOI: 10.1088/0967-3334/32/7/S15 Open DOISearch in Google Scholar

Tucker AS, Fox RM and Sadleir RJ. Biocompatible, High Precision, Wideband, Improved Howland Current Source With Lead-Lag Compensation. IEEE Transactions on Biomedical Circuits and Systems 2013 Feb; vol. 7:63– 70. DOI: 10.1109/TBCAS.2012.2199114 Tucker AS Fox RM Sadleir RJ. Biocompatible, High Precision, Wideband, Improved Howland Current Source With Lead-Lag Compensation . IEEE Transactions on Biomedical Circuits and Systems 2013 Feb ; vol. 7 : 63 70 . DOI: 10.1109/TBCAS.2012.2199114 Open DOISearch in Google Scholar

Marcondes DWC, Bertemes-Filho P and Paterno AS. Current Oscillator Based on Pyragas Model for Electrical Bioimpedance Applications. en. Electronics 2022 Jan; vol. 11. Number: 17 Publisher: Multidisciplinary Digital Publishing Institute. DOI: 10.3390/electronics11172653 Marcondes DWC Bertemes-Filho P Paterno AS. Current Oscillator Based on Pyragas Model for Electrical Bioimpedance Applications. en . Electronics 2022 Jan ; vol. 11 . Number: 17 Publisher: Multidisciplinary Digital Publishing Institute . DOI: 10.3390/electronics11172653 Open DOISearch in Google Scholar

Bertemes-Filho P. Tissue Characterisation using an Impedance Spectroscopy Probe. en. PhD thesis. University of Sheffield, 2002 Bertemes-Filho P. Tissue Characterisation using an Impedance Spectroscopy Probe. en. PhD thesis . University of Sheffield , 2002 Search in Google Scholar

Bertemes-Filho P, Felipe A and Vincence VC. High Accurate Howland Current Source: Output Constraints Analysis. en. Circuits and Systems 2013; vol. 4:451–8. DOI: 10.4236/cs.2013.47059 Bertemes-Filho P Felipe A Vincence VC. High Accurate Howland Current Source: Output Constraints Analysis . en. Circuits and Systems 2013 ; vol. 4 : 451 8 . DOI: 10.4236/cs.2013.47059 Open DOISearch in Google Scholar

A Comprehensive Study of the Howland Current Pump. Texas Instruments. Available from: https://www.ti.com/lit/an/snoa474a/snoa474a.pdf A Comprehensive Study of the Howland Current Pump . Texas Instruments . Available from: https://www.ti.com/lit/an/snoa474a/snoa474a.pdf Search in Google Scholar

Silva PD da and Bertemes Filho P. Switched CMOS current source compared to enhanced Howland circuit for bio-impedance applications. Journal of electrical bioimpedance 2024; 15:145–53. DOI: 10.2478/joeb-2024-0017 Silva PD da Bertemes Filho P. Switched CMOS current source compared to enhanced Howland circuit for bio-impedance applications . Journal of electrical bioimpedance 2024 ; 15 : 145 53 . DOI: 10.2478/joeb-2024-0017 Open DOISearch in Google Scholar