Acceso abierto

A Modified Standardized Method to Extract and Store Insect Hemolymph with Use of a Glass Capillary


Cite

Fig. 1

The scheme of the modified technique of collecting hemolymph flowing out after detachment of the antennae with use of a glass capillary
The scheme of the modified technique of collecting hemolymph flowing out after detachment of the antennae with use of a glass capillary

Characterization of the modified method of collecting hemolymph compared to methods presented in the publication by Łoś & Strachecka (2018)

hemolymph outflowAfter detachment of antennaeAfter incision of body with a scalpelinto a glass capillary by puncturing bodyAfter detachment of antennae with glass capillary (modified method)
Difficulty leveleasydifficultdifficult and requiring precisioneasy
Microbiological contamination of collected materiallikelyvery likelyunlikelyunlikely
Transportvery difficultvery difficultdifficulteasy
Approximate amount of collected material5-10 μL2-8 μL6-20 μL8-20 μL
Stage of insects used for hemolymph extractionadultadult and larvaeadult with developed circulatory systemadult
Storage of collected materialdifficultdifficulteasyeasy
Collecting efficiencyfastslowslowfast
Possibility of hemocytes adhesionnonoyesyes
eISSN:
2299-4831
Idioma:
Inglés
Calendario de la edición:
2 veces al año
Temas de la revista: