Comparison of Equivalent Doses Obtained with Various post-IR IRSL Dating Protocols of K-Feldspar
, , , , y
31 dic 2021
Acerca de este artículo
Categoría del artículo: Conference Proceedings of the 5Asia Pacific Luminescence and Electron Spin Resonance Dating Conference October 15–17, 2018, Beijing, China. Guest Editor: Grzegorz Adamiec
Publicado en línea: 31 dic 2021
Páginas: 129 - 137
Recibido: 15 ene 2019
Aceptado: 29 oct 2019
DOI: https://doi.org/10.2478/geochr-2020-0010
Palabras clave
© 2019 Junjie Zhang et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Fig. 6

Dose rates and ages of the samples using the five protocols_
A-570 | 15 ± 5 | 2.03 | 9.55 ± 0.15 | 3.21 ± 0.12 | 116 ± 12 | 132 ± 6 | 129 ± 6 | \ | 119 ± 6 |
A-1050 | 15 ± 5 | 2.19 | 10.83 ± 0.16 | 3.44 ± 0.13 | 179 ± 17 | 206 ± 13 | 206 ± 9 | \ | 217 ± 17 |
B-0 | 15 ± 5 | 1.95 | 10.14 ± 0.18 | 3.30 ± 0.12 | 165 ± 8 | 204 ± 19 | 194 ± 8 | 216 ± 19 | 260 ± 24 |
B-610 | 19.3 ± 5 | 2.50 | 11.88 ± 0.19 | 3.55 ± 0.13 | 183 ± 9 | 206 ± 10 | 212 ± 9 | 217 ± 15 | 260 ± 20 |
B-640 | 19.3 ± 5 | 2.40 | 11.85 ± 0.19 | 3.59 ± 0.13 | 171 ± 16 | 206 ± 9 | 215 ± 10 | 209 ± 18 | 251 ± 17 |
B-1000 | 15 ± 5 | 2.22 | 10.74 ± 0.18 | 3.43 ± 0.13 | 189 ± 19 | 240 ± 14 | 222 ± 11 | 233 ± 16 | 261 ± 23 |
De values obtained using the five protocols_ In the ‘MAR with heat’ protocol, the first ‘n’ indicates the aliquots used to measure the natural signal, and the second refers to the aliquots used to measure the signal of a regenerative dose_
A-570 | 570 | 373 ± 35 | 7 | 424 ± 11 | 19 | 415 ± 9 | 15 | \ | \ | 381 ± 11 | 12;12 |
A-1050 | 1050 | 615 ± 54 | 7 | 706 ± 34 | 8 | 706 ± 17 | 8 | \ | \ | 747 ± 53 | 16;8 |
B-0 | 220 | 543 ± 17 | 6 | 673 ± 57 | 4 | 640 ± 13 | 8 | 712 ± 57 | 6 | 856 ± 73 | 24;14 |
B-610 | 830 | 652 ± 20 | 10 | 734 ± 21 | 14 | 753 ± 17 | 9 | 773 ± 45 | 6 | 925 ± 62 | 24;20 |
B-640 | 860 | 613 ± 51 | 6 | 741 ± 18 | 9 | 773 ± 22 | 7 | 749 ± 57 | 6 | 901 ± 51 | 14;10 |
B-1000 | 1190 | 649 ± 61 | 6 | 822 ± 35 | 5 | 762 ± 25 | 7 | 800 ± 47 | 6 | 897 ± 71 | 24;20 |
The five post-IR IRSL dating protocols used in this study_ The first four are the SAR protocols with pIR50IR290, pIR200IR290, MET-pIRIR250 and MET-pIRIR300 signals, respectively_ The fifth is the MAR protocol with the MET-pIRIR300 signal and a ‘cutheat to 500°C’ treatment added before the test dose, simplified as ‘MAR with heat’ (modified from Li et al_ (2013))_
1 | ||||||
2 | Preheat at 320°C, 60 s | Preheat at 300°C or 320°C, 60 s | Preheat at 320°C, 60 s | |||
3 | IRSL 200 s at 50/200°C | IRSL 100 s at 50°C | IRSL 100 s at 50°C | |||
4 | IRSL 200 s at 290°C | IRSL 100 s at 100°C | IRSL 100 s at 100°C | |||
5 | IRSL 100 s at 150°C | IRSL 100 s at 150°C | ||||
6 | IRSL 100 s at 200°C | IRSL 100 s at 200°C | ||||
7 | IRSL 100 s at 250°C | Lx (250) | IRSL 100 s at 250°C | |||
8 | IRSL 100 s at 300°C or not | Lx (300) | IRSL 100 s at 300°C | Lx (300) | ||
9 | ||||||
10 | ||||||
11 | Preheat at 320°C, 60 s | Preheat at 300°C or 320°C, 60 s | Preheat at 320°C, 60 s | |||
12 | IRSL 200 s at 50/200°C | IRSL 100 s at 50°C | IRSL 100 s at 50°C | |||
13 | IRSL 200 s at 290°C | IRSL 100 s at 100°C | IRSL 100 s at 100°C | |||
14 | IR at 325°C, 200 s | IRSL 100 s at 150°C | IRSL 100 s at 150°C | |||
15 | Return to step 1 | IRSL 100 s at 200°C | IRSL 100 s at 200°C | |||
16 | IRSL 100 s at 250°C | Tx (250) | IRSL 100 s at 250°C | |||
17 | IRSL 100 s at 300°C or not | Tx (300) | IRSL 100 s at 300°C | Tx (300) | ||
IR at 320 or 325°C, 100 s | ||||||
Return to step 1 |