Login
Registrieren
Passwort zurücksetzen
Veröffentlichen & Verteilen
Verlagslösungen
Vertriebslösungen
Themen
Allgemein
Altertumswissenschaften
Architektur und Design
Bibliotheks- und Informationswissenschaft, Buchwissenschaft
Biologie
Chemie
Geowissenschaften
Geschichte
Industrielle Chemie
Informatik
Jüdische Studien
Kulturwissenschaften
Kunst
Linguistik und Semiotik
Literaturwissenschaft
Materialwissenschaft
Mathematik
Medizin
Musik
Pharmazie
Philosophie
Physik
Rechtswissenschaften
Sozialwissenschaften
Sport und Freizeit
Technik
Theologie und Religion
Wirtschaftswissenschaften
Veröffentlichungen
Zeitschriften
Bücher
Konferenzberichte
Verlage
Blog
Kontakt
Suche
EUR
USD
GBP
Deutsch
English
Deutsch
Polski
Español
Français
Italiano
Warenkorb
Home
Zeitschriften
Journal of Electrical Bioimpedance
Band 6 (2015): Heft 1 (January 2015)
Uneingeschränkter Zugang
Parallel, multi frequency EIT measurement, suitable for recording impedance changes during epilepsy
T. Dowrick
T. Dowrick
,
G. Sato Dos Santos
G. Sato Dos Santos
,
A. Vongerichten
A. Vongerichten
und
D. Holder
D. Holder
| 21. Dez. 2015
Journal of Electrical Bioimpedance
Band 6 (2015): Heft 1 (January 2015)
Über diesen Artikel
Vorheriger Artikel
Nächster Artikel
Zusammenfassung
Artikel
Figuren und Tabellen
Referenzen
Autoren
Artikel in dieser Ausgabe
Vorschau
PDF
Zitieren
Teilen
Article Category:
Articles
Online veröffentlicht:
21. Dez. 2015
Seitenbereich:
37 - 43
Eingereicht:
02. Dez. 2015
DOI:
https://doi.org/10.5617/jeb.2573
Schlüsselwörter
Electrical Impedance Tomography (EIT)
,
Biomedical Circuits
,
Epilepsy
© 2015 T. Dowrick, G. Sato Dos Santos, A. Vongerichten and D. Holder, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 3.0 License.
Fig. 1
A - Current source implementation. Sine wave generation performed by Arduino Nano with output filtering. Howland current pump used for V-I conversion. B – Example connection of multiple current sources to phantom.
Fig. 2
Output impedance of current source. Measured using HP43284A Impedance Analyser.
Fig. 3
Stability of current source over time, measured on a resistor phantom. The slight drift over time is thought be caused by device heating.
Fig. 4
Results of imaging test. Blue areas represent an increase in impedance. The first column indicates the position of the perturbation in the tank. The remaining columns show the reconstructed images for each frequency group used. Colour bar indicates percentage change in impedance.
Fig 5
Results of coin drop experiment. 10 frames are shown, taken 10 ms apart, for each coin dropped. Each frame uses 1 ms of recorded data. The black circle at 0 ms indicates the position at which the coin was dropped.
Fig. 6
(A) Experimental Setup. 60 electrodes were placed on either side of the brain. Seizures were triggered using a 4-AP Model. (B) Data extraction. By low pass (EEG) and bandpass (EIT) filtering, the data was split into the EEG component and the EIT component, from which the impedance change was extracted.
Fig. 7
dZ values recorded at 2.2 kHz and 2.6 kHz during a single seizure. Seizure onset is at t = 0 . Right and left refers to the site of electrode placement.
Fig. 8
Example of raw recorded data, recorded from the right hemisphere. Solid colours represent the EEG data. dZ values, from 2.2 kHz injection, are plotted on top of each channel in grey.
List of frequency groups
Group A
1800 Hz
1900 Hz
2000 Hz
2100 Hz
Group B
1980 Hz
1990 Hz
2000 Hz
2010 Hz
Group C
1998 Hz
1999 Hz
2000 Hz
2001 Hz