Gamma radiation calculations and gamma blocker design for the high-energy beam transport region of the European Spallation Source
17. Sept. 2021
Über diesen Artikel
Artikel-Kategorie: Original Paper
Online veröffentlicht: 17. Sept. 2021
Seitenbereich: 99 - 102
Eingereicht: 08. Mai 2020
Akzeptiert: 15. März 2021
DOI: https://doi.org/10.2478/nuka-2021-0014
Schlüsselwörter
© 2021 Karol S. Szymczyk, published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
The purpose of this paper is to present the Monte-Carlo calculations performed to design a special element called gamma blocker (GB), necessary to stop the gamma radiation in the Accelerator-to-Target (A2T) section of European Spallation Source (ESS) linac. Very high levels of gamma radiation emitted backward from the activated target through the beam pipe could effectively block any human intervention close to the beam transport system. The residual dose rate in the linac tunnel was calculated without and with different GBs as a function of time. The final GB material and dimensions are proposed.