Uneingeschränkter Zugang

Systematic variability in ICG recordings results in ICG complex subtypes – steps towards the enhancement of ICG characterization


Zitieren

J. Nyboer, "Bagno, s., Barnett, A, Halsey, RH Radiocardiograms: Electricalmpedance Changes of the Heart in Relation to Electrocardiograms and Heart Sounds," J. Clin. nves., 19, vol. 963, 1940.NyboerJ.Bagnos.BarnettAHalseyRHRadiocardiograms: Electricalmpedance Changes of the Heart in Relation to Electrocardiograms and Heart SoundsJ. Clin. nves199631940Search in Google Scholar

W. Kubicek, D. Witsoe, R. Patterson, M. Mosharrata, J. Karnegis, and A. From, "Development and evaluation of an impedance cardiographic system to measure cardiac output and development o5 an oxygen consumption rate computing system utilizing a quadrapole mass spectrometer," National Aeronautics and Space Administration, NASA-CR-92220. (Also N68-32973.), 1967.KubicekW.WitsoeD.PattersonR.MosharrataM.KarnegisJ.FromA."Development and evaluation of an impedance cardiographic system to measure cardiac output and development o5 an oxygen consumption rate computing system utilizing a quadrapole mass spectrometer," National Aeronautics and Space AdministrationNASA-CR-92220. (Also N68-32973.)1967Search in Google Scholar

W. R. Patterson and J. Shewchun, "Alternate approach to the resolution of tunneling current structure by differentiation," Review of Scientific Instruments, vol. 35, pp. 1704-1707, 1964. https://doi.org/10.1063/1.1719283PattersonW. R.ShewchunJ."Alternate approach to the resolution of tunneling current structure by differentiation,"Review of Scientific Instruments35170417071964https://doi.org/10.1063/1.171928310.1063/1.1719283Search in Google Scholar

J. Karnegis, W. Kubicek, R. Mattson, R. Patterson, and D. Witsoe, "Development and evaluation of an impedance cardiac output system," 1966.KarnegisJ.KubicekW.MattsonR.PattersonR.WitsoeD."Development and evaluation of an impedance cardiac output system,"1966Search in Google Scholar

W. Kubicek, R. Patterson, and D. Witsoe, "Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular system," Annals of the New York Academy of Sciences, vol. 170, pp. 724-732, 1970. https://doi.org/10.1111/j.1749-6632.1970.tb17735.xKubicekW.PattersonR.WitsoeD."Impedance cardiography as a noninvasive method of monitoring cardiac function and other parameters of the cardiovascular systemAnnals of the New York Academy of Sciences1707247321970https://doi.org/10.1111/j.1749-6632.1970.tb17735.x10.1111/j.1749-6632.1970.tb17735.xSearch in Google Scholar

Z. Lababidi, D. Ehmke, R. E. Durnin, P. E. Leaverton, and R. M. Lauer, "The first derivative thoracic impedance cardiogram," Circulation, vol. 41, pp. 651-658, 1970. https://doi.org/10.1161/01.CIR.41.4.651LababidiZ.EhmkeD.DurninR. E.LeavertonP. E.LauerR. M."The first derivative thoracic impedance cardiogram,"Circulation416516581970https://doi.org/10.1161/01.CIR.41.4.65110.1161/01.CIR.41.4.6515437409Search in Google Scholar

M. T. Allen, J. Fahrenberg, R. M. Kelsey, W. R. Lovallo, and L. J. Doornen, "Methodological guidelines for impedance cardiography," Psychophysiology, vol. 27, pp. 1-23, 1990. https://doi.org/10.1111/j.1469-8986.1990.tb02171.xAllenM. T.FahrenbergJ.KelseyR. M.LovalloW. R.DoornenL. J."Methodological guidelines for impedance cardiography,"Psychophysiology271231990https://doi.org/10.1111/j.1469-8986.1990.tb02171.x10.1111/j.1469-8986.1990.tb02171.x2187214Search in Google Scholar

D. Bernstein and H. J. Lemmens, "Stroke volume equation for impedance cardiography," Medical and Biological Engineering and Computing, vol. 43, pp. 443-450, 2005. https://doi.org/10.1007/BF02344724BernsteinD.LemmensH. J."Stroke volume equation for impedance cardiography,"Medical and Biological Engineering and Computing434434502005https://doi.org/10.1007/BF0234472410.1007/BF0234472416255425Search in Google Scholar

R. L. Summers, W. C. Shoemaker, W. F. Peacock, D. S. Ander, and T. G. Coleman, "Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography," Academic emergency medicine, vol. 10, pp. 669-680, 2003. https://doi.org/10.1197/aemj.10.6.669SummersR. L.ShoemakerW. C.PeacockW. F.AnderD. S.ColemanT. G."Bench to bedside: electrophysiologic and clinical principles of noninvasive hemodynamic monitoring using impedance cardiography,"Academic emergency medicine106696802003https://doi.org/10.1197/aemj.10.6.66910.1111/j.1553-2712.2003.tb00054.x12782531Search in Google Scholar

A. P. DeMarzo and R. M. Lang, "A new algorithm for improved detection of aortic valve opening by impedance cardiography," in Computers in Cardiology, 1996, 1996, pp. 373-376.DeMarzoA. P.LangR. M."A new algorithm for improved detection of aortic valve opening by impedance cardiography,"in Computers in Cardiology19961996, pp37337610.1109/CIC.1996.542551Search in Google Scholar

D. L. Lozano, G. Norman, D. Knox, B. L. Wood, B. D. Miller, C. F. Emery, et al., "Where to B in dZ/dt," Psychophysiology, vol. 44, pp. 113-119, 2007. https://doi.org/10.1111/j.1469-8986.2006.00468.xLozanoD. L.NormanG.KnoxD.WoodB. L.MillerB. D.EmeryC. F."Where to B in dZ/dt,"Psychophysiology441131192007https://doi.org/10.1111/j.1469-8986.2006.00468.x10.1111/j.1469-8986.2006.00468.x17241147Search in Google Scholar

J. H. Meijer, S. Boesveldt, E. Elbertse, and H. Berendse, "Method to measure autonomic control of cardiac function using time interval parameters from impedance cardiography," Physiological measurement, vol. 29, p. S383, 2008. https://doi.org/10.1088/0967-3334/29/6/S32MeijerJ. H.BoesveldtS.ElbertseE.BerendseH."Method to measure autonomic control of cardiac function using time interval parameters from impedance cardiography,"Physiological measurement29S3832008https://doi.org/10.1088/0967-3334/29/6/S3210.1088/0967-3334/29/6/S3218544834Search in Google Scholar

M. Handke, C. Jahnke, G. Heinrichs, J. Schlegel, C. Vos, D. Schmitt, et al., "New three-dimensional echocardiographic system using digital radiofrequency data—visualization and quantitative analysis of aortic valve dynamics with high resolution: methods, feasibility, and initial clinical experience," Circulation, vol. 107, pp. 2876-2879, 2003. https://doi.org/10.1161/01.CIR.0000077909.54159.B4HandkeM.JahnkeC.HeinrichsG.SchlegelJ.VosC.SchmittD."New three-dimensional echocardiographic system using digital radiofrequency data—visualization and quantitative analysis of aortic valve dynamics with high resolution: methods, feasibility, and initial clinical experience,"Circulation107287628792003https://doi.org/10.1161/01.CIR.0000077909.54159.B410.1161/01.CIR.0000077909.54159.B412782569Search in Google Scholar

W. Kubicek, J. Kottke, M. U. Ramos, R. Patterson, D. Witsoe, J. Labree, et al., "The Minnesota impedance cardiograph-theory and applications," Biomedical engineering, vol. 9, p. 410, 1974.KubicekW.KottkeJ.RamosM. U.PattersonR.WitsoeD.LabreeJ."The Minnesota impedance cardiograph-theory and applications,"Biomedical engineering94101974Search in Google Scholar

A. P. DeMarzo, "Using impedance cardiography to detect subclinical cardiovascular disease in women with multiple risk factors: a pilot study," Preventive cardiology, vol. 12, pp. 102108, 2009. https://doi.org/10.1111/j.1751-7141.2008.00012.xDeMarzoA. P."Using impedance cardiography to detect subclinical cardiovascular disease in women with multiple risk factors: a pilot study,"Preventive cardiology121021082009https://doi.org/10.1111/j.1751-7141.2008.00012.x10.1111/j.1751-7141.2008.00012.x19476584Search in Google Scholar

T. Kööbi, M. Kähönen, T. Iivainen, and V. Turjanmaa, "Simultaneous non‐invasive assessment of arterial stiffness and haemodynamics–a validation study," Clinical physiology and functional imaging, vol. 23, pp. 31-36, 2003. https://doi.org/10.1046/j.1475-097X.2003.00465.xKööbiT.KähönenM.IivainenT.TurjanmaaV."Simultaneous non‐invasive assessment of arterial stiffness and haemodynamics–a validation study,"Clinical physiology and functional imaging2331362003https://doi.org/10.1046/j.1475-097X.2003.00465.x10.1046/j.1475-097X.2003.00465.x12558611Search in Google Scholar

G. Cybulski, "Ambulatory impedance cardiography," in Ambulatory Impedance Cardiography, ed: Springer, 2011, pp. 39-56.CybulskiG."Ambulatory impedance cardiography,"Ambulatory Impedance CardiographySpringer2011395610.1007/978-3-642-11987-3_3Search in Google Scholar

K. Sakamoto, K. Muto, H. Kanai, and M. Iizuka, "Problems of impedance cardiography," Medical and Biological Engineering and Computing, vol. 17, pp. 697-709, 1979. https://doi.org/10.1007/BF02441549SakamotoK.MutoK.KanaiH.IizukaM."Problems of impedance cardiography,"Medical and Biological Engineering and Computing176977091979https://doi.org/10.1007/BF0244154910.1007/BF02441549317910Search in Google Scholar

M. Ulbrich, J. Mühlsteff, S. Leonhardt, and M. Walter, "Influence of physiological sources on the impedance cardiogram analyzed using 4D FEM simulations," Physiological measurement, vol. 35, p. 1451, 2014. https://doi.org/10.1088/0967-3334/35/7/1451UlbrichM.MühlsteffJ.LeonhardtS.WalterM."Influence of physiological sources on the impedance cardiogram analyzed using 4D FEM simulations,"Physiological measurement3514512014https://doi.org/10.1088/0967-3334/35/7/145110.1088/0967-3334/35/7/145124901446Search in Google Scholar

M. Ulbrich, J. Muhlsteff, P. Paluchowski, and S. Leonhardt, "Erythrocyte orientation and lung conductivity analysis with a high temporal resolution FEM model for bioimpedance measurements," Lecture Notes on Impedance Spectroscopy: Measurement, Modeling and Applications, vol. 3, p. 71, 2012.UlbrichM.MuhlsteffJ.PaluchowskiP.LeonhardtS."Erythrocyte orientation and lung conductivity analysis with a high temporal resolution FEM model for bioimpedance measurements,"Lecture Notes on Impedance Spectroscopy: Measurement, Modeling and Applications3712012Search in Google Scholar

P. Carvalho, R. P. Paiva, J. Henriques, M. Antunes, I. Quintal, and J. Muehlsteff, "Robust Characteristic Points for ICG-Definition and Comparative Analysis," in BIOSIGNALS, 2011, pp. 161-168.CarvalhoP.PaivaR. P.HenriquesJ.AntunesM.QuintalI.MuehlsteffJ."Robust Characteristic Points for ICG-Definition and Comparative Analysis,"BIOSIGNALS2011161168Search in Google Scholar

BIOPAC Systems Inc. (2018). Biopac AcqKnowledge impedance. Available: [Online]: https://www.biopac.comBIOPAC Systems Inc2018Biopac AcqKnowledge impedanceAvailable: [Online]https://www.biopac.comSearch in Google Scholar

Y. Miyamoto, M. Takahashi, T. Tamura, T. Nakamura, T. Hiura, and M. Mikami, "Continuous determination of cardiac output during exercise by the use of impedance plethysmography," Medical and Biological Engineering and Computing, vol. 19, pp. 638-644, 1981. https://doi.org/10.1007/BF02442779MiyamotoY.TakahashiM.TamuraT.NakamuraT.HiuraT.MikamiM."Continuous determination of cardiac output during exercise by the use of impedance plethysmography,"Medical and Biological Engineering and Computing196386441981https://doi.org/10.1007/BF0244277910.1007/BF024427797334873Search in Google Scholar

H. Riese, P. F. Groot, M. van den Berg, N. H. Kupper, E. H. Magnee, E. J. Rohaan, et al., "Large-scale ensemble averaging of ambulatory impedance cardiograms," Behavior Research Methods, vol. 35, pp. 467-477, 2003. https://doi.org/10.3758/BF03195525RieseH.GrootP. F.van den BergM.KupperN. H.MagneeE. H.RohaanE. J."Large-scale ensemble averaging of ambulatory impedance cardiograms,"Behavior Research Methods354674772003https://doi.org/10.3758/BF0319552510.3758/BF03195525Search in Google Scholar

J. C. M. Ruiz, M. Rempfler, F. Seoane, and K. Lindecrantz, "Textrode-enabled transthoracic electrical bioimpedance measurements-towards wearable applications of impedance cardiography," Journal of Electrical Bioimpedance, vol. 4, pp. 45-50, 2013.RuizJ. C. M.RempflerM.SeoaneF.LindecrantzK."Textrode-enabled transthoracic electrical bioimpedance measurements-towards wearable applications of impedance cardiography,"Journal of Electrical Bioimpedance44550201310.5617/jeb.542Search in Google Scholar

M. Rempfler, "On the Feasibility of Textrodes for Impedance Cardiography," BIOMEDICAL ENGINEERING, University of Borås, 2011.RempflerM."On the Feasibility of Textrodes for Impedance Cardiography,"BIOMEDICAL ENGINEERINGUniversity of Borås2011Search in Google Scholar

A. Hafid, S. Benouar, M. Kedir-Talha, F. Abtahi, M. Attari, and F. Seoane, "Full Impedance Cardiography measurement device using Raspberry PI3 and System-on-Chip biomedical Instrumentation Solutions," IEEE Journal of Biomedical and Health Informatics, 2017.HafidA.BenouarS.Kedir-TalhaM.AbtahiF.AttariM.SeoaneF."Full Impedance Cardiography measurement device using Raspberry PI3 and System-on-Chip biomedical Instrumentation Solutions,"IEEE Journal of Biomedical and Health Informatics201710.1109/JBHI.2017.278394929990025Search in Google Scholar

J. Pan and W. J. Tompkins, "A real-time QRS detection algorithm," IEEE transactions on biomedical engineering, pp. 230-236, 1985. https://doi.org/10.1109/TBME.1985.325532PanJ.TompkinsW. J."A real-time QRS detection algorithm,"IEEE transactions on biomedical engineering2302361985https://doi.org/10.1109/TBME.1985.32553210.1109/TBME.1985.3255323997178Search in Google Scholar

S. Thomas, "Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise," British journal of clinical pharmacology, vol. 34, p. 467, 1992.ThomasS."Impedance cardiography using the Sramek-Bernstein method: accuracy and variability at rest and during exercise,"British journal of clinical pharmacology344671992Search in Google Scholar

N. C. S. Capela, "IMPEDANCE CARDIOGRAPHY," University of Coimbra, 2013.CapelaN. C. S."IMPEDANCE CARDIOGRAPHY,"University of Coimbra2013Search in Google Scholar

G. Cotter, A. Schachner, L. Sasson, H. Dekel, and Y. Moshkovitz, "Impedance cardiography revisited," Physiological measurement, vol. 27, p. 817, 2006. https://doi.org/10.1088/0967-3334/27/9/005CotterG.SchachnerA.SassonL.DekelH.MoshkovitzY."Impedance cardiography revisited,"Physiological measurement278172006https://doi.org/10.1088/0967-3334/27/9/00510.1088/0967-3334/27/9/00516868348Search in Google Scholar

M. Ulbrich, P. Paluchowski, J. Mühlsteff, and S. Leonhardt, "High temporal resolution finite element simulations of the aorta for thoracic impedance cardiography," in Computing in Cardiology, 2011, 2011, pp. 149-152.UlbrichM.PaluchowskiP.MühlsteffJ.LeonhardtS."High temporal resolution finite element simulations of the aorta for thoracic impedance cardiography,"Computing in Cardiology, 20112011149152Search in Google Scholar

eISSN:
1891-5469
Sprache:
Englisch
Zeitrahmen der Veröffentlichung:
Volume Open
Fachgebiete der Zeitschrift:
Technik, Bioingenieurwesen, Biomedizinische Elektronik, Biologie, Biophysik, Medizin, Biomedizinische Technik, Physik, Spektroskopie und Metrologie