1. |
Exits are not to be less than the required number and capacity as per the code. |
|
✓ |
2. |
Exit doors are swinging in the direction of egress. |
|
✓ |
3. |
The travel distance does not exceed 15 meters. |
|
✓ |
4. |
Exterior doors are leading to discharge outside the building, or a public path. |
|
✓ |
5. |
Corridors are always lighted when the building is occupied. |
✓ |
|
6. |
Exit signs are available, and lighted throughout the building. |
✓ |
|
7. |
There are no barriers that would reduce the width of any exit. |
✓ |
|
8. |
The phrase “PUSH TO EXIT” is available on all fire doors. |
|
✓ |
9. |
Exit lighting could be operated using a standby power supply in case of an absence of municipal power supply. |
✓ |
|
B. Fire protection systems
|
|
|
10. |
An automatic sprinkler system is installed throughout all floors. |
|
✓ |
11. |
Fire extinguishers are placed every 22 meters, in visible locations. |
✓ |
|
12. |
Fire extinguishers are mounted on walls. |
|
✓ |
13. |
Fire extinguishers are inspected annually. |
✓ |
|
14. |
There is no paint over sprinkler heads, except that of the factory. |
✓ |
|
15. |
Records of fire protection systems’ inspections are kept for the past 3 years. |
✓ |
|
16. |
A 1 meter net space is provided around every fire hydrant. |
|
✓ |
17. |
Fire alarms are provided throughout the building. |
✓ |
|
C. Electrical installation and distribution systems
|
|
|
18. |
Power taps are directly plugged into permeant sockets. |
✓ |
|
19. |
Relocatable cords are not passing through interior walls, finished floors, ceilings, doors or floor finishes, and are not subjected to harm. |
✓ |
|
20. |
Extension cords are not an alternative to permanent wiring. |
✓ |
|
21. |
Extension cords are not damaged. |
✓ |
|
22. |
There are no open junction boxes, as well as open wiring connections. |
✓ |
|
23. |
Electrical motors do not have any accumulations of oil or dirt. |
✓ |
|
24. |
The phrase “ELECTRICAL ROOM” is available on all doors of electrical rooms. |
✓ |
|
D. Fire doors
|
|
|
25. |
Fire doors are not blocked in any way. |
|
✓ |
26. |
The assemblies of fire doors are not modified in any way. |
|
✓ |
27. |
Fire doors’ closers have enough force to close and latch the door. |
|
✓ |
28. |
Fire doors remain in closed positions at all times. |
|
✓ |
E. Housekeeping practices
|
|
|
29. |
Storage containing combustibles are kept in an organized manner. |
✓ |
|
30. |
The storage space is isolated from heat sources. |
✓ |
|
31. |
There are no combustibles stored in exits, exit enclosures, boiler, mechanical, and electrical rooms. |
✓ |
|
32. |
Dumpsters and containers are adequately provides throughout the building. |
✓ |
|
F. Miscellaneous fire safety requirements
|
|
|
33. |
The building has a clear, readable address number. |
|
✓ |
34. |
Accessibility to the fire hydrant are not obstructed in any way. |
|
✓ |
35. |
Evacuation plans are clearly posted throughout the building. |
✓ |
|
G. Hazardous materials
|
|
|
36. |
Flammable liquids are not available in the basement. |
✓ |
|
37. |
There are no more than 10 gallons of flammable and combustible liquids used for operation and maintenance of equipment. |
✓ |
|
38. |
There is no excessive storage of gas containers throughout the building. |
✓ |
|