[1. Hazrati, S., Rostami, R., Fazlzadeh, M. & Pourfarzi, F. (2016). Benzene, toluene, ethylbenzene and xylene concentrations in atmospheric ambient air of gasoline and CNG refueling stations. Air Qual Atmos Health. 9, 403–409. DOI: 10.1007/s11869-015-0349-0.10.1007/s11869-015-0349-0]Open DOISearch in Google Scholar
[2. Elke, K., Jermann, E., Begerow, J. & Dunemann, L. (1998). Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and highresolution gas chromatography–flame ionization detection. J. Chromatogr. A. 826, 191–200. DOI: 10.1016/S0021-9673(98)00736-5.10.1016/S0021-9673(98)00736-5]Open DOISearch in Google Scholar
[3. Tumbiolo, S., Gal, J.F., Maria, P.C. & Zerbinati, O. (2005). SPME sampling of btex before gc/ms analysis: examples of outdoor and indoor air quality measurements in public and private sites. Ann. Chim. 95, 757–766. DOI: 10.1002/adic.200590089.10.1002/adic.200590089]Open DOISearch in Google Scholar
[4. Lee, M.R., Chang, C.M. & Dou, J. (2007). Determination of benzene, toluene, ethylbenzene, xylenes in water at sub-ng l-1 levels by solid-phase microextraction coupled to cryo-trap gas chromatography-mass spectrometry. Chemosphere 69, 1381–1387. DOI: 10.1016/j.chemosphere.2007.05.004.10.1016/j.chemosphere.2007.05.004]Open DOISearch in Google Scholar
[5. Hoskins, J.A. (2011). Health effects due to indoor air pollution. Survival and sustainability. (pp. 665–676). Springer, Berlin Heidelberg.]Search in Google Scholar
[6. Tumbiolo, S., Gal, J.F., Maria, P.C. & Zerbinati, O. (2004). Determination of benzene, toluene, ethylbenzene and xylenes in air by solid phase micro-extraction / gas chromatography/mass spectrometry. Anal. Bioanal. Chem. 380, 824–830. DOI: 10.1007/s00216-004-2837-1.10.1007/s00216-004-2837-1]Open DOISearch in Google Scholar
[7. Jia, M., Koziel, J. & Pawliszyn, J. (2000). Fast field sampling/sample preparation and quantification of volatile organic compounds in indoor air by solid-phase microextraction and portable gas chromatography. Field Anal Chem. Tech. 4, 73–84. DOI: 10.1002/1520-6521(2000)4:2/3<73::AID-FACT2>3.0.CO;2-7.10.1002/1520-6521(2000)4:2/3<73::AID-FACT2>3.0.CO;2-7]Open DOISearch in Google Scholar
[8. Koziel, J., Jia, M., Khaled, A., Noah, J. & Pawliszyn, J. (1999). Field air analysis with SPME device. Anal. Chim. Acta. 400, 153–162. DOI: 10.1016/S0003-2670(99)00614-5.10.1016/S0003-2670(99)00614-5]Search in Google Scholar
[9. Koziel, J. & Pawliszyn, J. (2011). Air sampling and analysis of volatile organic compounds with solid phase microextraction. Air & Waste Manage. Assoc. 51, 173–184. DOI: 10.1080/10473289.2001.10464263.10.1080/10473289.2001.10464263]Open DOISearch in Google Scholar
[10. Souza-Silva, É.A., Jiang, R., Rodríguez-Lafuente, A., Gionfriddo, E. & Pawliszyn, J. (2015). A critical review of the state of the art of solid-phase microextraction of complex matrices I. Environmental analysis. Trends Anal. Chem. 71, 224–235. DOI: 10.1016/j.trac.2015.04.016.10.1016/j.trac.2015.04.016]Search in Google Scholar
[11. Zare Sakhvidi, M.J., Bahrami, A., Afkhami, A. & Rafiei, A. (2012). Development of diffusive solid phase microextraction method for sampling of epichlorohydrin in air. Int. J. Environ. Anal. Chem. 92, 1365–1377. DOI: 10.1080/03067319.2011.620704.10.1080/03067319.2011.620704]Open DOISearch in Google Scholar
[12. Isetun, S., Nilsson, U., Colmsjö, A. & Johansson, R. (2004). Air sampling of organophosphate triesters using SPME under non-equilibrium conditions. Anal. Bioanal. Chem. 378, 1847–1853. DOI: 10.1007/s00216-003-2489-6.10.1007/s00216-003-2489-614762647]Open DOISearch in Google Scholar
[13. Gholivand, M.B., Shamsipur, M., Shamizadeh, M., Moradian, R. & Astinchap, B. (2014). Cobalt oxide nanoparticles as a novel high-efficiency fiber coating for solid phase microextraction of benzene, toluene, ethylbenzene and xylene from aqueous solutions. Anal. Chim. Acta 822, 30–36. DOI: 10.1016/j.aca.2014.02.032.10.1016/j.aca.2014.02.03224725745]Open DOISearch in Google Scholar
[14. Zare Sakhvidi, M.J., Bahrami, A., Ghiasvand, A., Mahjub, H. & Tuduri, L. (2012). Determination of inhalational anesthetics in Field and laboratory by SPME GC/M. Anal Lett. 45, 375–385. DOI: 10.1080/00032719.2011.644736.10.1080/00032719.2011.644736]Open DOISearch in Google Scholar
[15. Ezquerro, Ó., Ortiz, G., Pons, B. & Tena, M.T. (2004). Determination of benzene, toluene, ethylbenzene and xylenes in soils by multiple headspace solid-phase microextraction; J. Chromat. A. 1035, 17–22. DOI: 10.1016/j.chroma.2004.02.030.10.1016/j.chroma.2004.02.03015117069]Open DOISearch in Google Scholar
[16. Heidari, M., Bahrami, A., Ghiasvand, A., Shana, F.G., Soltanian, A. & Rafieiemam, M. (2016). Application of graphene nanoplatelets silica composite, prepared by sol–gel technology, as a novel sorbent in two microextraction techniques. J. Sep. Sci. 38, 4225–4232. DOI: 10.1002/jssc.201500975.10.1002/jssc.20150097526459611]Open DOISearch in Google Scholar
[17. Martendal, E. & Carasek, E. (2011). A new optimization strategy for gaseous phase sampling by an internally cooled solid-phase microextraction technique. J Chromat. A. 1218, 367–372. DOI: 10.1016/j.chroma.2010.11.041.10.1016/j.chroma.2010.11.04121146826]Open DOISearch in Google Scholar
[18. Banitaba, M.H., Hosseiny Davarani, S.S. & Kazemi Movahed, S. (2014). Comparison of direct, headspace and headspace cold fiber modes in solid phase microextraction of polycyclic aromatic hydrocarbons by a new coating based on poly (3,4-ethylenedioxythiophene)/graphene oxide composite. J. Chromat. A.1325, 23–30. DOI: 10.1016/j.chroma.2013.11.056.10.1016/j.chroma.2013.11.05624373534]Open DOISearch in Google Scholar
[19. Zhang, Z. & Pawliszyn, J. (1995). Quantitative extraction using an internally cooled solid phase microextraction device. Anal. Chem. 67, 34–43. DOI: 10.1021/ac00097a007.10.1021/ac00097a007]Open DOISearch in Google Scholar
[20. Martendal, E. & Carasek, E. (2011). A new approach based on a combination of direct and headspace cold-fiber solid-phase microextraction modes in the same procedure for the determination of polycyclic aromatic hydrocarbons and phthalate esters in soil samples. J. Chromat. A. 1218, 1707–1714. DOI: 10.1016/j.chroma.2011.01.074.10.1016/j.chroma.2011.01.07421316689]Open DOISearch in Google Scholar
[21. Ghiasvand, A.R., Hosseinzadeh, S. & Pawliszyn, J. (2006). New cold-fiber headspace solid-phase microextraction device for quantitative extraction of polycyclic aromatic hydrocarbons in sediment. J. Chromat. A. 1124, 35–42. DOI: 10.1016/j.chroma.2006.04.088.10.1016/j.chroma.2006.04.08816714028]Open DOISearch in Google Scholar
[22. Chen, Y. & Pawliszyn, J. (2006). Miniaturization and automation of an internally cooled coated fiber device. Anal. Chem. 78, 5222–5226. DOI: 10.1021/ac060542k.10.1021/ac060542k]Open DOISearch in Google Scholar
[23. Ghiasvand, A., Setkova, L. & Pawliszyn, J. (2007). Determination of flavour profile in Iranian fragrant rice samples using cold-fibre SPME–GC–TOF–MS. Flav. Fragr. 22, 377–391. DOI: 10.1002/ffj.1809.10.1002/ffj.1809]Open DOISearch in Google Scholar
[24. Haddadi, S.H. & Pawliszyn, J. (2009). Cold fiber solid-phase microextraction device based on thermoelectric cooling of metal fiber. J. Chromat. A. 1216, 2783–2788. DOI: 10.1016/j.chroma.2008.09.005.10.1016/j.chroma.2008.09.005]Open DOISearch in Google Scholar
[25. Haddadi, S.H., Niri, V.H. & Pawliszyn, J. (2009). Study of desorption kinetics of polycyclic aromatic hydrocarbons (PAHs) from solid matrices using internally cooled coated fiber. Anal. Chim. Acta 652, 224–30. DOI: 10.1016/j.aca.2009.05.026.10.1016/j.aca.2009.05.026]Open DOISearch in Google Scholar
[26. Carasek, E. & Pawliszyn, J. (2006). Screening of tropical fruit volatile compounds using solid-phase microextraction (SPME) fibers and internally cooled SPME fiber. J. Agric. Food Chem. 54, 8688–8696. DOI: 10.1021/jf0613942.10.1021/jf0613942]Open DOISearch in Google Scholar
[27. Menezes, H.C., Paiva, M.N., Santos, R.R., Sousa, L.P., Resende, S.F., Saturnino, J.A., Paulo, B.P. & Cardeal, Z.L. (2013). A sensitive GC/MS method using cold fiber SPME to determine polycyclic aromatic hydrocarbons in spring water. Microchem. J.110, 209–214. DOI: 10.1016/j.microc.2013.03.010.10.1016/j.microc.2013.03.010]Open DOISearch in Google Scholar
[28. Ji, J., Deng, C., Shen, W. & Zhang, X. (2006). Field analysis of benzene, toluene, ethylbenzene and xylene in water by portable gas chromatography-microflame ionization detector combined with headspace solid-phase microextraction. Talanta 69, 894–899. DOI: 10.1016/j.talanta.2005.11.032.10.1016/j.talanta.2005.11.032]Open DOISearch in Google Scholar
[29. Woolcock, P.J., Koziel, J., Cai, L., Johnston, P.A. & Brown, R.C. (2013). Analysis of trace contaminants in hot gas streams using time-weighted average solid-phase microextraction: Proof of concept. J. Chromat. A.1281, 1–8. DOI: 10.1016/j.chroma.2013.01.036.10.1016/j.chroma.2013.01.036]Open DOISearch in Google Scholar
[30. Elke, K., Jermann, E., Begerow, J. & Dunemann, L. (1998). Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and high-resolution gas chromatography-flame ionization detection. J. Chromat. A. 826, 191–200. DOI: 10.1016/S0021-9673(98)00736-5.10.1016/S0021-9673(98)00736-5]Open DOISearch in Google Scholar
[31. NIOSH. (2003). Hydrocarbons, aromatic. https://www.cdc.gov/niosh/docs/2003-154/pdfs/1501.pdf (Accessed November 7, 2014).]Search in Google Scholar
[32. Merib, J., Nardini, G., Bianchin, J.N., Dias, A.N., Simão, V. & Carasek, E. (2013). Use of two different coating temperatures for a cold fiber headspace solid-phase microextraction system to determine the volatile profile of Brazilian medicinal herbs. J. Sep. Sci. 36, 1410–1417. DOI: 10.1002/jssc.201201148.10.1002/jssc.20120114823505225]Open DOISearch in Google Scholar
[33. Attari, S.G., Bahrami, A., Shana, G.F. & Heidari, M. (2014). Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air. J. Environ. Health Sci. Eng. 12, 123. DOI: 10.1186/s40201-014-0123-5.10.1186/s40201-014-0123-5418172525279223]Open DOISearch in Google Scholar
[34. Koziel, J., Jia, M. & Pawliszyn, J. (2000). Air sampling with porous solid-phase microextraction fibers. Anal. Chem. 72, 5178–5186. DOI: 10.1021/ac000518l.10.1021/ac000518l11080861]Open DOISearch in Google Scholar
[35. Jiang, R., Carasek, E., Risticevic, S., Cudjoe, E., Warren, J. & Pawliszyn, J. (2012). Evaluation of a completely automated cold fiber device using compounds with varying volatility and polarity. Anal. Chim. Acta. 742, 22–29. DOI: 10.1016/j.aca.2012.01.010.10.1016/j.aca.2012.01.01022884203]Open DOISearch in Google Scholar
[36. EURACHEM Guide. (2014). The fitness for perpose of analytical methods. http://www.eurachem.org/index.php/publications/guides/mv. (Accessed November 10, 2014).]Search in Google Scholar