Open Access

Determination of benzene, toluene, ethylbenzene and xylene in field and laboratory by means of cold fiber SPME equipped with thermoelectric cooler and GC/FID method


Cite

1. Hazrati, S., Rostami, R., Fazlzadeh, M. & Pourfarzi, F. (2016). Benzene, toluene, ethylbenzene and xylene concentrations in atmospheric ambient air of gasoline and CNG refueling stations. Air Qual Atmos Health. 9, 403–409. DOI: 10.1007/s11869-015-0349-0.10.1007/s11869-015-0349-0Open DOISearch in Google Scholar

2. Elke, K., Jermann, E., Begerow, J. & Dunemann, L. (1998). Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and highresolution gas chromatography–flame ionization detection. J. Chromatogr. A. 826, 191–200. DOI: 10.1016/S0021-9673(98)00736-5.10.1016/S0021-9673(98)00736-5Open DOISearch in Google Scholar

3. Tumbiolo, S., Gal, J.F., Maria, P.C. & Zerbinati, O. (2005). SPME sampling of btex before gc/ms analysis: examples of outdoor and indoor air quality measurements in public and private sites. Ann. Chim. 95, 757–766. DOI: 10.1002/adic.200590089.10.1002/adic.200590089Open DOISearch in Google Scholar

4. Lee, M.R., Chang, C.M. & Dou, J. (2007). Determination of benzene, toluene, ethylbenzene, xylenes in water at sub-ng l-1 levels by solid-phase microextraction coupled to cryo-trap gas chromatography-mass spectrometry. Chemosphere 69, 1381–1387. DOI: 10.1016/j.chemosphere.2007.05.004.10.1016/j.chemosphere.2007.05.004Open DOISearch in Google Scholar

5. Hoskins, J.A. (2011). Health effects due to indoor air pollution. Survival and sustainability. (pp. 665–676). Springer, Berlin Heidelberg.Search in Google Scholar

6. Tumbiolo, S., Gal, J.F., Maria, P.C. & Zerbinati, O. (2004). Determination of benzene, toluene, ethylbenzene and xylenes in air by solid phase micro-extraction / gas chromatography/mass spectrometry. Anal. Bioanal. Chem. 380, 824–830. DOI: 10.1007/s00216-004-2837-1.10.1007/s00216-004-2837-1Open DOISearch in Google Scholar

7. Jia, M., Koziel, J. & Pawliszyn, J. (2000). Fast field sampling/sample preparation and quantification of volatile organic compounds in indoor air by solid-phase microextraction and portable gas chromatography. Field Anal Chem. Tech. 4, 73–84. DOI: 10.1002/1520-6521(2000)4:2/3<73::AID-FACT2>3.0.CO;2-7.10.1002/1520-6521(2000)4:2/3<73::AID-FACT2>3.0.CO;2-7Open DOISearch in Google Scholar

8. Koziel, J., Jia, M., Khaled, A., Noah, J. & Pawliszyn, J. (1999). Field air analysis with SPME device. Anal. Chim. Acta. 400, 153–162. DOI: 10.1016/S0003-2670(99)00614-5.10.1016/S0003-2670(99)00614-5Search in Google Scholar

9. Koziel, J. & Pawliszyn, J. (2011). Air sampling and analysis of volatile organic compounds with solid phase microextraction. Air & Waste Manage. Assoc. 51, 173–184. DOI: 10.1080/10473289.2001.10464263.10.1080/10473289.2001.10464263Open DOISearch in Google Scholar

10. Souza-Silva, É.A., Jiang, R., Rodríguez-Lafuente, A., Gionfriddo, E. & Pawliszyn, J. (2015). A critical review of the state of the art of solid-phase microextraction of complex matrices I. Environmental analysis. Trends Anal. Chem. 71, 224–235. DOI: 10.1016/j.trac.2015.04.016.10.1016/j.trac.2015.04.016Search in Google Scholar

11. Zare Sakhvidi, M.J., Bahrami, A., Afkhami, A. & Rafiei, A. (2012). Development of diffusive solid phase microextraction method for sampling of epichlorohydrin in air. Int. J. Environ. Anal. Chem. 92, 1365–1377. DOI: 10.1080/03067319.2011.620704.10.1080/03067319.2011.620704Open DOISearch in Google Scholar

12. Isetun, S., Nilsson, U., Colmsjö, A. & Johansson, R. (2004). Air sampling of organophosphate triesters using SPME under non-equilibrium conditions. Anal. Bioanal. Chem. 378, 1847–1853. DOI: 10.1007/s00216-003-2489-6.10.1007/s00216-003-2489-614762647Open DOISearch in Google Scholar

13. Gholivand, M.B., Shamsipur, M., Shamizadeh, M., Moradian, R. & Astinchap, B. (2014). Cobalt oxide nanoparticles as a novel high-efficiency fiber coating for solid phase microextraction of benzene, toluene, ethylbenzene and xylene from aqueous solutions. Anal. Chim. Acta 822, 30–36. DOI: 10.1016/j.aca.2014.02.032.10.1016/j.aca.2014.02.03224725745Open DOISearch in Google Scholar

14. Zare Sakhvidi, M.J., Bahrami, A., Ghiasvand, A., Mahjub, H. & Tuduri, L. (2012). Determination of inhalational anesthetics in Field and laboratory by SPME GC/M. Anal Lett. 45, 375–385. DOI: 10.1080/00032719.2011.644736.10.1080/00032719.2011.644736Open DOISearch in Google Scholar

15. Ezquerro, Ó., Ortiz, G., Pons, B. & Tena, M.T. (2004). Determination of benzene, toluene, ethylbenzene and xylenes in soils by multiple headspace solid-phase microextraction; J. Chromat. A. 1035, 17–22. DOI: 10.1016/j.chroma.2004.02.030.10.1016/j.chroma.2004.02.03015117069Open DOISearch in Google Scholar

16. Heidari, M., Bahrami, A., Ghiasvand, A., Shana, F.G., Soltanian, A. & Rafieiemam, M. (2016). Application of graphene nanoplatelets silica composite, prepared by sol–gel technology, as a novel sorbent in two microextraction techniques. J. Sep. Sci. 38, 4225–4232. DOI: 10.1002/jssc.201500975.10.1002/jssc.20150097526459611Open DOISearch in Google Scholar

17. Martendal, E. & Carasek, E. (2011). A new optimization strategy for gaseous phase sampling by an internally cooled solid-phase microextraction technique. J Chromat. A. 1218, 367–372. DOI: 10.1016/j.chroma.2010.11.041.10.1016/j.chroma.2010.11.04121146826Open DOISearch in Google Scholar

18. Banitaba, M.H., Hosseiny Davarani, S.S. & Kazemi Movahed, S. (2014). Comparison of direct, headspace and headspace cold fiber modes in solid phase microextraction of polycyclic aromatic hydrocarbons by a new coating based on poly (3,4-ethylenedioxythiophene)/graphene oxide composite. J. Chromat. A.1325, 23–30. DOI: 10.1016/j.chroma.2013.11.056.10.1016/j.chroma.2013.11.05624373534Open DOISearch in Google Scholar

19. Zhang, Z. & Pawliszyn, J. (1995). Quantitative extraction using an internally cooled solid phase microextraction device. Anal. Chem. 67, 34–43. DOI: 10.1021/ac00097a007.10.1021/ac00097a007Open DOISearch in Google Scholar

20. Martendal, E. & Carasek, E. (2011). A new approach based on a combination of direct and headspace cold-fiber solid-phase microextraction modes in the same procedure for the determination of polycyclic aromatic hydrocarbons and phthalate esters in soil samples. J. Chromat. A. 1218, 1707–1714. DOI: 10.1016/j.chroma.2011.01.074.10.1016/j.chroma.2011.01.07421316689Open DOISearch in Google Scholar

21. Ghiasvand, A.R., Hosseinzadeh, S. & Pawliszyn, J. (2006). New cold-fiber headspace solid-phase microextraction device for quantitative extraction of polycyclic aromatic hydrocarbons in sediment. J. Chromat. A. 1124, 35–42. DOI: 10.1016/j.chroma.2006.04.088.10.1016/j.chroma.2006.04.08816714028Open DOISearch in Google Scholar

22. Chen, Y. & Pawliszyn, J. (2006). Miniaturization and automation of an internally cooled coated fiber device. Anal. Chem. 78, 5222–5226. DOI: 10.1021/ac060542k.10.1021/ac060542kOpen DOISearch in Google Scholar

23. Ghiasvand, A., Setkova, L. & Pawliszyn, J. (2007). Determination of flavour profile in Iranian fragrant rice samples using cold-fibre SPME–GC–TOF–MS. Flav. Fragr. 22, 377–391. DOI: 10.1002/ffj.1809.10.1002/ffj.1809Open DOISearch in Google Scholar

24. Haddadi, S.H. & Pawliszyn, J. (2009). Cold fiber solid-phase microextraction device based on thermoelectric cooling of metal fiber. J. Chromat. A. 1216, 2783–2788. DOI: 10.1016/j.chroma.2008.09.005.10.1016/j.chroma.2008.09.005Open DOISearch in Google Scholar

25. Haddadi, S.H., Niri, V.H. & Pawliszyn, J. (2009). Study of desorption kinetics of polycyclic aromatic hydrocarbons (PAHs) from solid matrices using internally cooled coated fiber. Anal. Chim. Acta 652, 224–30. DOI: 10.1016/j.aca.2009.05.026.10.1016/j.aca.2009.05.026Open DOISearch in Google Scholar

26. Carasek, E. & Pawliszyn, J. (2006). Screening of tropical fruit volatile compounds using solid-phase microextraction (SPME) fibers and internally cooled SPME fiber. J. Agric. Food Chem. 54, 8688–8696. DOI: 10.1021/jf0613942.10.1021/jf0613942Open DOISearch in Google Scholar

27. Menezes, H.C., Paiva, M.N., Santos, R.R., Sousa, L.P., Resende, S.F., Saturnino, J.A., Paulo, B.P. & Cardeal, Z.L. (2013). A sensitive GC/MS method using cold fiber SPME to determine polycyclic aromatic hydrocarbons in spring water. Microchem. J.110, 209–214. DOI: 10.1016/j.microc.2013.03.010.10.1016/j.microc.2013.03.010Open DOISearch in Google Scholar

28. Ji, J., Deng, C., Shen, W. & Zhang, X. (2006). Field analysis of benzene, toluene, ethylbenzene and xylene in water by portable gas chromatography-microflame ionization detector combined with headspace solid-phase microextraction. Talanta 69, 894–899. DOI: 10.1016/j.talanta.2005.11.032.10.1016/j.talanta.2005.11.032Open DOISearch in Google Scholar

29. Woolcock, P.J., Koziel, J., Cai, L., Johnston, P.A. & Brown, R.C. (2013). Analysis of trace contaminants in hot gas streams using time-weighted average solid-phase microextraction: Proof of concept. J. Chromat. A.1281, 1–8. DOI: 10.1016/j.chroma.2013.01.036.10.1016/j.chroma.2013.01.036Open DOISearch in Google Scholar

30. Elke, K., Jermann, E., Begerow, J. & Dunemann, L. (1998). Determination of benzene, toluene, ethylbenzene and xylenes in indoor air at environmental levels using diffusive samplers in combination with headspace solid-phase microextraction and high-resolution gas chromatography-flame ionization detection. J. Chromat. A. 826, 191–200. DOI: 10.1016/S0021-9673(98)00736-5.10.1016/S0021-9673(98)00736-5Open DOISearch in Google Scholar

31. NIOSH. (2003). Hydrocarbons, aromatic. https://www.cdc.gov/niosh/docs/2003-154/pdfs/1501.pdf (Accessed November 7, 2014).Search in Google Scholar

32. Merib, J., Nardini, G., Bianchin, J.N., Dias, A.N., Simão, V. & Carasek, E. (2013). Use of two different coating temperatures for a cold fiber headspace solid-phase microextraction system to determine the volatile profile of Brazilian medicinal herbs. J. Sep. Sci. 36, 1410–1417. DOI: 10.1002/jssc.201201148.10.1002/jssc.20120114823505225Open DOISearch in Google Scholar

33. Attari, S.G., Bahrami, A., Shana, G.F. & Heidari, M. (2014). Solid-phase microextraction fiber development for sampling and analysis of volatile organohalogen compounds in air. J. Environ. Health Sci. Eng. 12, 123. DOI: 10.1186/s40201-014-0123-5.10.1186/s40201-014-0123-5418172525279223Open DOISearch in Google Scholar

34. Koziel, J., Jia, M. & Pawliszyn, J. (2000). Air sampling with porous solid-phase microextraction fibers. Anal. Chem. 72, 5178–5186. DOI: 10.1021/ac000518l.10.1021/ac000518l11080861Open DOISearch in Google Scholar

35. Jiang, R., Carasek, E., Risticevic, S., Cudjoe, E., Warren, J. & Pawliszyn, J. (2012). Evaluation of a completely automated cold fiber device using compounds with varying volatility and polarity. Anal. Chim. Acta. 742, 22–29. DOI: 10.1016/j.aca.2012.01.010.10.1016/j.aca.2012.01.01022884203Open DOISearch in Google Scholar

36. EURACHEM Guide. (2014). The fitness for perpose of analytical methods. http://www.eurachem.org/index.php/publications/guides/mv. (Accessed November 10, 2014).Search in Google Scholar

eISSN:
1899-4741
Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Industrial Chemistry, Biotechnology, Chemical Engineering, Process Engineering