Characteristics and performance of different methods for the identification of S. aureus in the blood or blood cultures.

Assays Resistance markers Sensitivity Turnaround time (h) Specificity References
Hybrisep none NA NA 8 Shimada et al. 1999
T2Dx none 100% 100% 3–5 De Angelis et al. 2018
BinaX Now S.aureus none 97.6% 100% 0.5 Qian et al. 2014
BinaX Now PBP2a yes 100% 100% 0.5 Heraud et al. 2015
Gram staining none 78.7% 95% 0.5 Hadano et al. 2018
PNA FISH none 100% 99.4% 1.5–3 González et al. 2004
QuickFISH none 99.5% 89.5% 0.5 Deck et al. 2012
Accelerate PhenoTM system susceptibility 94.7% 99% ID1/AST 7 Charnot-Katsikas et al. 2017
MALDI-TOF MS in development 85.7–100% NA 0.5–1 (pellet)/3–5 (short incubation) Foster 2013; Curtoni et al. 2017
FilmArray BCID2 yes 100% 100% 1 Holma et al. 2022
Xpert MRSA/SA BC yes 100% 100% 1 McHugh et al. 2020

Comments on rapid and simple methods for the identification of S. aureus from the blood or blood cultures.

Assays Automated Personnel experience Equipment requirement Throughput Cost Comments
Hybrisep yes yes proprietary equipment low moderate +: rapid, sensitive and specific–: limited number of publications
T2Dx yes no proprietary equipment low high +: rapid, sensitive, and specific–: no resistance markers
BinaX Now S. aureus no no no low low +: rapid, sensitive and specific–: cross-reaction with S. lugdunensis
BinaX Now PBP2a no no no low low +: rapid, sensitive, and specific–: no identification
Gram staining yes yes generic equipment low low +: rapid, simple–: variable sensitivity and specificity
PNA FISH no yes generic equipment low high +: rapid, sensitive, and specific–: no resistance markers
QuickFISH no yes generic equipment low high +: rapid, sensitive, and specific–: no resistance markers
Accelerate PhenoTM system yes no proprietary equipment low high +: rapid, sensitive, and specific, with AST results–: low throughout
MALDI-TOF MS no yes proprietary equipment high low +: rapid, sensitive, and specific, cost-effective–: enrichment, not standardization
FilmArray BCID2 yes no proprietary equipment low high +: rapid, sensitive, and specific, with resistance results–: low throughout
Xpert MRSA/SA BC yes no proprietary equipment low high +: rapid, sensitive, and specific, with resistance results–: expensive