Open Access

Twin Rooms – Experimental Facility for Research on Advanced Facades

, , ,  and   
Dec 30, 2024

Cite
Download Cover

Baker, P.H. - van Dijk, H.A.L. (2008) PASLINK and dynamic outdoor testing of building components. Building and Environment, vol. 43, no. 2, pp. 143–151, Feb. 2008, doi: 10.1016/J.BUILDENV.2006.10.009. Online. Available at: https://www.researchgate.net/publication/223414824_PASLINK_and_dynamic_outdoor_testing_of_building_components [viewed 2024-08-14].Open DOISearch in Google Scholar

Goia, F. - Schlemminger, C. - Gustavsen, A. (2017) The ZEB Test Cell Laboratory. A facility for characterization of building envelope systems under real outdoor conditions. Energy Procedia 132. 531-536. 10.1016/j.egypro.2017.09.718. Online. Available at: https://www.researchgate.net/publication/320477392_The_ZEB_Test_Cell_Laboratory_A_facility_for_characterization_of_building_envelope_systems_under_real_outdoor_conditions [viewed 2024-08-14].Search in Google Scholar

Gratia, E. - De Herde, A. (2007) The most efficient position of shading devices in a double-skin facade. Energy and Buildings 39(3). 364 – 373. Online. Available at: https://www.researchgate.net/publication/223796058_The_most_efficient_position_of_shading_devices_in_a_double-skin_facade [viewed 2024-11-27].Search in Google Scholar

Janssens, A. - Roels, S. - Vandaele, L. (2011) Full scale test facilities for evaluation of energy and hygrothermal performances. ISBN 978-94-9069-584-2. Online. Available at: https://core.ac.uk/download/pdf/55745987.pdf [viewed 2024-08-14]Search in Google Scholar

Kalyanova, O. - Heiselberg, P. (2008) Experimental Set-up and Full-scale measurements in the ‘Cube'. Department of Civil Engineering, Aalborg University. DCE Technical reports No. 34, 58 pp. Online. Available at: https://vbn.aau.dk/en/publications/experimental-set-up-and-full-scale-measurements-in-the-cube [viewed 2024-08-14].Search in Google Scholar

Kaniková, K. (2024) Aerodynamika štrbinových medzipriestorov dvojitých transparentných fasád. [Aerodynamics of slot cavities of double skin transparent facades.] (Doctoral dissertation, Slovak University of Technology in Bratislava)Search in Google Scholar

Kaniková, K. (2022) Prehľad meracích zariadení použitých na kvantifikáciu dvojitých transparentných fasád a príprava na meranie. [Overview of measuring equipment used for quantification of double-skin transparent facades and preparation for measurement.] Online. In: Zborník AACEE (Advances in Architectural, Civil and Environmental Engineering) 2022. Available at: https://www.svf.stuba.sk/aacee.html?page_id=8527 [viewed 2024-08-14].Search in Google Scholar

Liu, M. - Wittchen, K.B. - Heiselberg, P.K. (2014) Verification of a simplified method for intelligent glazed façade design under different control strategies in a full-scale façade test facility – Preliminary results of a south facing single zone experiment for a limited summer period. Building and Environment 82, pp. 400-407, ISSN 0360-1323, Available at: https://doi.org/10.1016/J.buildenv.2014.09.009Search in Google Scholar

Roig, O. - Cuerva, E. - Pardal, C. - Guardo, A. - Isalgue, A. - Lopez-Besora, J. (2023) Thermal Assessment of a Ventilated Double Skin Façade Component with a Set of Air Filtering Photocatalytic Slats in the Cavity. Buildings 13, 272. Available at: https://doi.org/10.3390/buildings13020272 [viewed 2024-11-27].Search in Google Scholar

Saelens, D. - Roels, S. - Hens, H. (2004) The inlet temperature as a boundary condition for multiple-skin facade modelling. Energy and Buildings 36, pp. 825-835, ISSN 0378-7788, Available at: https://doi.org/10.1016/j.enbuild.2004.01.005, https://www.sciencedirect.com/science/article/pii/S0378778804000349 [viewed 2024-08-14].Search in Google Scholar

Technische Hochschule Rosenheim website (2024) Laboratory for Intelligent Building Technology. Online. Available at: https://www.th-rosenheim.de/en/die-hochschule/labore/labore-ang/rosenheim-technology-centre-for-energy-and-buildings-roteg/laboratory-for-intelligent-building-technology [viewed 2024-08-14].Search in Google Scholar

Van Dijk, H. A. L. - Van der Linden, G. P. (1993) The PASSYS method for testing passive solar components. Online. Building and Environment, Vol. 28, No. 2, 1993, pp. 115-126, ISSN 0360-1323, Available at: https://doi.org/10.1016/0360-1323(93)90045-5 [viewed 2024-11-27]Search in Google Scholar

ZEB website. Test Cell Laboratory. Online. Available at: https://www.zeb.no/index.php/en/test-cell-laboratory [viewed 2024-08-14].Search in Google Scholar

Language:
English
Publication timeframe:
4 times per year
Journal Subjects:
Engineering, Introductions and Overviews, Engineering, other