Multi-Criteria Decision Analysis Approach for DC Microgrid Bus Selection
Jun 19, 2025
About this article
Article Category: Research Paper
Published Online: Jun 19, 2025
Page range: 157 - 175
Received: Mar 03, 2025
Accepted: May 15, 2025
DOI: https://doi.org/10.2478/pead-2025-0010
Keywords
© 2025 Foued Charaabi et al., published by Sciendo
This work is licensed under the Creative Commons Attribution 4.0 International License.
Figure 1.

Figure 2.

Figure 3.

Figure 4.

Figure 5.

Figure 6.

Figure 7.

Figure 8.

Figure 9.

Figure 10.

Figure 11.

Figure 12.

Figure 13.

Figure 14.

Figure 15.

Figure 16.

Figure 17.

Figure 18.

Figure 19.

Figure 20.

Figure 21.

Saaty’s comparison note (Saaty and Vargas, 2012)
1 | 3 | 5 | 7 | 9 | 2, 4, 6, 8 | |
---|---|---|---|---|---|---|
Equally important | Moderate important | Strong important | Very strong important | Extreme important | Moderate values |
Alternatives and criteria
A1 | Unipolar microgrid | ||
A2 | Bipolar microgrid | ||
A3 | Ring topology | ||
A4 | Multi-terminal topology | ||
A5 | Multi-bus topology | ||
C1 | Cost | ||
C2 | Protection | ||
C3 | Resilience |
Consumer scenarios
Combined criteria | C1 = C2 = C3 | C2 > C3 > C1 | C2 > C1 > C3 | C3 > C2 > C1 | C3 > C1 > C2 | C1 > C2 > C3 | C1 > C3 > C2 |
Data from scientific articles
Unipolar DC MG | Economical for basic setups | Limited | Low |
Bipolar DC MG | Moderate | Enhanced redundancy (20%) | Moderate |
Ring topology | Moderate | Self-healing capabilities (30%) | Moderate |
Multi-terminal | High | Adaptive energy management (20%) | High |
Multi-bus | High | Fault isolation and modular replacement (30%) | High |
Cost component comparison (Eskander and Silva, 2023; Jena et al_, 2021)
Component | PV | Wind (1 kW) | Boost | Buck | AC/DC | Bid- conv | Balancer converter | Circuit breaker | Cables (3 kW) | Total cost |
---|---|---|---|---|---|---|---|---|---|---|
Topology | ||||||||||
Unipolar DC MG (3 kW) | €2,000 (CS6K-300) | €2,500 (Bergey Excel) | €350 (Energy Skylla) | €200 (MeanWell) | €800 (SMA Sunny Island) | €800 (SMA Sunny Island) | Not required | €150 (ABB S202) | €200 (Sola Cable) | €6,150 |
Bipolar DC MG (3 kW) | €2,000 (CS6K-300) | €2,500 (Bergey Excel) | €350 (E. Skylla) | €200 (MeanWell) | €800 (SMA Sunny Island) | €800 (SMA Sunny Island) | €600 (Victron Energy BMV-702) | €150 (ABB S202) | €200 (Solar Cable) | €11,07 |
Microgrids in the literature (Kumar and Prabha, 2022; Punitha et al_, 2024)
AC microgrid | AC | Standard, widely used, less efficient for DC systems | 25 |
Unipolar DC microgrid | DC | Simple, low-cost, suitable for small-scale systems | 13 |
Bipolar DC microgrid | DC | More reliable, reduces losses compared to unipolar | 12 |
Multi-terminal DC | DC | Connects multiple sources and loads, modular | 11 |
Multi-bus DC | DC | Flexible load distribution and efficient control | 10 |
Ring DC | DC | High resilience, continuous power supply | 10 |
Radial DC | DC | Simple, but vulnerable to faults; low redundancy | 5 |
Mesh DC | DC | High reliability, but complex control | 4 |
Star DC | DC | Centralised, best for small systems | 3 |
Microgrids and bus characteristics
Topology | Unipolar DC microgrid | Bipolar DC microgrid |
---|---|---|
Bus parameters | Single positive rail and ground | Positive, neutral and negative rails |
Bus voltage | Single voltage (positive to ground) | Three-wire voltage (positive, neutral and negative) |
Bus complexity | Simpler, with fewer components | More complex, with more components for balancing |
Protection | Simple overcurrent/short-circuit protection | More complex, requiring balancing and fault detection for both rails |
Voltage levels | 300 V | ±200 V |
Power of sources | Pv (2 kW), wind (1 kW) | Pv (2 kW), wind (1 kW) |
Load options | One voltage level per load, Load 1 (2 kW) | Load 2 (1 kW), load 3 (1 kW) |