Effect of electron beam irradiation on filtering facepiece respirators integrity and filtering efficiency
Jun 11, 2022
About this article
Article Category: Original Paper
Published Online: Jun 11, 2022
Page range: 23 - 33
Received: Mar 23, 2022
Accepted: May 16, 2022
DOI: https://doi.org/10.2478/nuka-2022-0002
Keywords
© 2022 Dagmara Chmielewska et al., published by Sciendo
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Fig. 1

Fig. 2
![The scheme of main particles deposition mechanisms on fiber material (A), diagram of the relationship between the filtration efficiency and the particle diameter for a given deposition mechanism; MPPS (B), the main filtration mechanism based on a given range of particle diameters (C). Reproduced with permission [17] Copyright © 2019 Elsevier Inc.](https://sciendo-parsed.s3.eu-central-1.amazonaws.com/6472611c215d2f6c89dc637e/j_nuka-2022-0002_fig_002.jpg?X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Credential=AKIA6AP2G7AKOUXAVR44%2F20250911%2Feu-central-1%2Fs3%2Faws4_request&X-Amz-Date=20250911T050658Z&X-Amz-Expires=3600&X-Amz-Signature=d7818df3f0b8284367c06d54afc3cedc5bd3a9e10ec048185ab9f64799bc0123&X-Amz-SignedHeaders=host&x-amz-checksum-mode=ENABLED&x-id=GetObject)
Fig. 3
![Scheme of the MFP nanoPlus – test bench for nanoparticle filtration. Reproduced with permission [35] Copyright © Taiwan Association for Aerosol Research.](https://sciendo-parsed.s3.eu-central-1.amazonaws.com/6472611c215d2f6c89dc637e/j_nuka-2022-0002_fig_003.jpg?X-Amz-Algorithm=AWS4-HMAC-SHA256&X-Amz-Content-Sha256=UNSIGNED-PAYLOAD&X-Amz-Credential=AKIA6AP2G7AKOUXAVR44%2F20250911%2Feu-central-1%2Fs3%2Faws4_request&X-Amz-Date=20250911T050658Z&X-Amz-Expires=3600&X-Amz-Signature=c5ff9aa607430eed4dd66d7e21ec00b3da87e896d68549b7b38768e52c854b85&X-Amz-SignedHeaders=host&x-amz-checksum-mode=ENABLED&x-id=GetObject)
Fig. 4

Fig. 5

Fig. 6

Fig. 7

Fig. 8

Fig. 9

Fig. 10

Fig. 11

Fig. 12

Fig. 13

Fig. 14

Fig. 15

Fig. 16

Fig. 17

Fig. 18

Average values of tensile strength together with SDs for all studied FFRs before and after irradiation
Mask type | Aura | VFlex | Surgical | |||
---|---|---|---|---|---|---|
Dose (kGy) | Tensile strength (MPa) | SD | Tensile strength (MPa) | SD | Tensile strength (MPa) | SD |
0 (control) | 1.91 | 0.14 | 3.17 | 0.34 | 2.20 | 0.16 |
12 | 2.35 | 0.66 | 2.78 | 0.33 | 2.21 | 0.32 |
25 | 2.05 | 0.32 | 2.51 | 0.20 | 2.07 | 0.22 |