1. bookVolume 19 (2019): Issue 3 (June 2019)
Journal Details
License
Format
Journal
eISSN
1335-8871
First Published
07 Mar 2008
Publication timeframe
6 times per year
Languages
English
access type Open Access

Hybrid Time-Base Device for Coherent Sampling Oscilloscope

Published Online: 26 Jun 2019
Volume & Issue: Volume 19 (2019) - Issue 3 (June 2019)
Page range: 93 - 100
Received: 23 Jan 2019
Accepted: 30 May 2019
Journal Details
License
Format
Journal
eISSN
1335-8871
First Published
07 Mar 2008
Publication timeframe
6 times per year
Languages
English
Abstract

In this paper, a hybrid time-base (HTB) device for the coherent sampling oscilloscope is presented. The HTB device makes it possible to reduce the uncertainty of determining the time position of the sample in the horizontal channel of the sampling oscilloscope. For its functioning, the proposed HTB device requires that the system-under-test, in addition to the test signal, also has a synchronous reference clock – harmonic oscillation. It should be noted that both the test signal and the harmonic reference clock are sampled simultaneously. The harmonic reference clock is connected to one of the oscilloscope channels and a special algorithm processes the clock samples and adjusts the coherent sampling mode. Two techniques of determining the position of the sample on the time axis are combined in the HTB device – the “trigonometric”, when the position is calculated by the arccosine or arcsine formula of the reference clock sampling value, and the interpolation method, according to which the time position of the sample is found by averaging the positions of two adjacent samples, obtained using said “trigonometric” technique. Primary experimental studies have shown that using the HTB device can reduce jitter of the sampling oscilloscope by several times and the drift with constant time distortion components is practically absent in this device.

Keywords

[1] Pereira, J.M.D. (2006). The history and technology of oscilloscopes. An overview of its primary characteristics and working principles. IEEE Instrumentation & Measurement Magazine, 9 (6), 27-35.Search in Google Scholar

[2] Hale, P., Williams, D.F., Remley, K.A. (2007). The sampling oscilloscope as a microwave instrument. IEEE Microwave Magazine, 8 (4), 59-68.Search in Google Scholar

[3] Remley, K.A., Gordon, J.A., Novotny, D., et. al. (2017). Measurement challenges for 5G and beyond. IEEE Microwave Magazine, (18) 5, 41–56.10.1109/MMM.2017.2690882Search in Google Scholar

[4] Avolio, G., Raffo, A., Jargon, J., Hale, P., Schreurs, D., Williams, D. (2015). Evaluation of uncertainty in temporal waveforms of microwave transistors. IEEE Transactions on Microwave Theory and Techniques, 63 (7), 2353–2363.10.1109/TMTT.2015.2432765Search in Google Scholar

[5] Tektronix, Inc. Digital serial analyzer sampling oscilloscope DSA8300. https://www.tek.com/oscilloscope/dsa8300-sampling-oscilloscope.Search in Google Scholar

[6] Keysight Technologies, Inc. N1094A DCA-M sampling oscilloscope. https://www.keysight.com/en/pdx-2738546-pn-N1094A/dca-m-sampling-oscilloscopetwo-electrical-channels?cc=LT&lc=eng.Search in Google Scholar

[7] Clement, T.S., Hale, P., Williams, D.F., Wang, C.M., Dienstfrey, A., Keenan, D.A. (2006). Calibration of sampling oscilloscopes with high-speed phootodiodes. IEEE Transacions on Microwave Theory and Techniquws, 54 (8), 3173-3181.10.1109/TMTT.2006.879135Search in Google Scholar

[8] Remley, K., Williams, D., Hale, P., Wang, C.-M., Jargon, J., Park, Y. (2015). Millimeter-wave modulated-signal and error-vector-magnitude measurement with uncertainty. IEEE Transactions on Microwave Theory and Techniques, 63 (5), 1710–1720.10.1109/TMTT.2015.2416180Search in Google Scholar

[9] Fuser, H., Eichstadt, S., Baaske, K., Elster, C., Kuhlmann, K., Judaschke, R., Pierz, K., Bieler, M. (2012). Optoelectronic time-domain characterization of a 100 GHz sampling oscilloscope. Measurement Science and Technology, 23 (2), 11 p.10.1088/0957-0233/23/2/025201Search in Google Scholar

[10] Yuan, W., Jiangmiao, Z., Jingyuan, M. (2013). Correction of time base error for high speed sampling oscilloscope. In IEEE 11th International Conference on Electronic Measurement & Instruments, Harbin, China. IEEE, 88-91.10.1109/ICEMI.2013.6743050Search in Google Scholar

[11] Wang, J.C.M., Hale, P.D., Jargon, J.A., Williams, D.F., Remley, K.A. (2012). Sequential estimation of timebase corrections for an arbitrarily long waveform. IEEE Transactions on Instrumentation and Measurement, 61 (10), 2689-2694.10.1109/TIM.2012.2193692Search in Google Scholar

[12] Cirulis, R., Greitans, M., Hermanis, E. (2013). Time domain distortion estimation and correction using sample shifting procedure. Elektronika ir elektrotechnika (Electronics and Electrical Engineering), 19 (9), 81-84.10.5755/j01.eee.19.9.5654Search in Google Scholar

[13] Jargon, J.A., Hale, P.D., Wang, C.M. (2010). Correcting sampling oscilloscope timebase errors with a passively mode-locked laser phase locked to a microwave oscillator. IEEE Transactions on Instrumentation and Measurement, 59 (4), 916-922.10.1109/TIM.2009.2030929Search in Google Scholar

[14] Boaventura, A., Williams, D., Avolio, G., Hale, P. (2018). Traceable characterization of broadband pulse waveforms suitable for cryogenic Josephson voltage applications. In 2018 IEEE/MTT-S International Microwave Symposium – IMS, Philadelphia, USA. IEEE, 1176–1179.10.1109/MWSYM.2018.8439425Search in Google Scholar

[15] Humphreys, D., Akmal, M. (2012). Channel timebase errors for Digital Sampling Oscilloscopes. In 2012 Conference on Precision electromagnetic Measurements. IEEE, 2 p.10.1109/CPEM.2012.6251032Search in Google Scholar

[16] Cho, C., Lee, J., Hale, P., Jargon, J., Jeavons, P., Schlager, J., Dienstfrey, A. (2016). Calibration of timeinterleaved errors in digital real-time oscilloscopes. IEEE Transactions on Microwave Theory and Techniques, 64 (11), 4071–4079.10.1109/TMTT.2016.2614928Search in Google Scholar

[17] Hale, P.D., Wang, C.M., Williams, D.F., Remley, K.A., Wepman, J. (2006) Compensation of a random and systematic timing errors in sampling oscilloscopes. IEEE Transactions on Instrumentation and Measurement, 55 (6), 2146-2154.10.1109/TIM.2006.880270Search in Google Scholar

[18] Hale, P.D., Diesnstfrey, A., Wang, J.C.M., Williams, D.F., Lewandowski, A., Keenan, D.A., Clement, T.S. (2009). Traceable waveform calibration with a covariance-based uncertainty analysis. IEEE Transactions on Instrumentation and Measurement, 58 (10), 3554-3568.10.1109/TIM.2009.2018012Search in Google Scholar

[19] Reader, H.C., Williams, D.F., Hale, P., Clement, T.S. (2008). Comb-generator characterization. IEEE Transacions on Microwave Theory and Techniques, 56 (2), 515-521.10.1109/TMTT.2007.914630Search in Google Scholar

[20] Nelson, M. (2000). A new technique for low-jitter measurements using equivalent-time sampling oscilloscopes. In 56th ARFTG Conference Digest, Boulder, USA. IEEE, 1-3.10.1109/ARFTG.2000.327422Search in Google Scholar

[21] IEEE. (2001). IEEE Standard for Digitizing Waveform.Search in Google Scholar